background image

Note:

 Rinse thoroughly after each cycle. We recommend ultrasonic cleaning and electrolytic 

degreasing. After cleaning, the product is dried without stains. It can now be covered with a 
cover pen, for example, or glued with adhesive film.  

Attention:

 It is essential to make sure that the surfaces to be coated (galvanized) must no 

longer be touched with the hands or other skin parts, possibly wear gloves. 

3.2 Electroplating  

• For galvanizing, the workpiece to be machined is contacted with the product clamp. 

 

• Set the voltage regulator to the appropriate voltage (LED). 

 

• Draw electrolyte from the electrolyte container with the felt of the electrode pin. 

 

• For electroplating, slide the electrode pin evenly over the surface of the workpiece several 
times, whereby between the surface of the goods and the felt of the electrode pin there should 
be a thin electrolyte film. 

 

• After galvanizing, rinse the product immediately in water to prevent staining and to avoid 
chemical  attack.  Then  remove  the  cover  surface  or  adhesive  film  and  degrease  again,  if 
necessary. Then rinse and dry again.

 

• Leave the felt in the pen (replace the soiled felt) and thoroughly soak again with the same 
electrolytes during a new process. 

Attention: 

The  electrolytes  must  not  be  mixed.  Different  felts  should  be  used  for  different 

electrolytes,  as  the  electrolytes  may  become  unusable  due  to  carryover.  In  order  not  to 
contaminate  the  electrolyte  in  the  reservoir,  used  electrolyte  should  not  be  returned  to  the 
original bottle. 

4. Sources of error  

4.1 The goods accept electrolyte only partially: 

 

  The product is stained or oxidized 

- Degrease the product thoroughly (see Chapter 3.1)  
- The felt must be completely soaked with electrolyte. 

 

  The felt is dirty.  

 - Change felt. 

 
4.2 No deposit takes place  

  There is no contact between the rectifier and the product.  

             - Check the contact from the rectifier to the product terminal  
              (black socket - cathode cable - terminal - commodity)  

  The goods are protected against tarnishing. 

             - Remove the varnish.  

   The power cord has not been plugged in or the device is not switched on.  

             - Check that the power cord is plugged into the power outlet. 

 

             - Check that the device is switched on. 

 

  The fuse is defective.  

             - The device must be checked and repaired by an authorized technician 
 
 
 

Отзывы: