Side 8 – Operating Instructions DIGITAL II and V 

 

Control functions 
1.

 

Heat protection / level regulator 

If the level is too low in a heated bath the heater is switched off by the thermo couple. The 
display shows a warning signal over the full area. The signal can be confirmed with “ok” but the 
heater remains off. An overheating of heater or tank is avoided.  When the bath is refilled the 
heater will be automatically turned on.  
 

2.

 

Total charge  

For  each  basin  a  total  charge  can  be  set.  So  a  metal  content  is  determined,  which  can  be 
deposited.  When  this  value  is  exceeded  a  warning  appears 

  and  the  bath  should  be 

regenerated. To set the total charge press button “Basin” for 3 sec and enter the desired value 
and (important!) basin. After this the display shows the signal 

  

 
If the total charge is matched with a desired program (by setting the number of the basin in that 
program) the control is done for this process. Do as following: 

1.

 

Press button “basin” 3 seconds 

2.

 

Enter the desired value and basin 

3.

 

Press “save”  

4.

 

Leave with “OK” 

5.

 

Press button “progr” and choose the desired one 

6.

 

Set the same basin as in point 2 

7.

 

Leave with “OK” 

8.

 

Press “progr” for 3 seconds and save the process 

9.

 

Leave with “OK” 

 
If basin number 0 is selected you can work manually (without control). 
 

Example total charge Rhodiumbath 

The deposition rate of the bath is 6 mg / Amin (see data sheet of the chemical supplier). For this 
the total charge of 200 Amin can be set. That means that after receiving this value 1200 mg of 
rhodium are deposited (6 mg/Amin x 200 Amin = 1200 mg Rh) and the bath can be regenerated 
accordingly.  A consisted quality is ensured. Rinsing losses are not taken into account! 
 

Heaters 

Up to max. two heaters can be connected with the corresponding sensors on the unit. These can be 
used in any tank. The tanks where heater and sensor hang will be heated.  The heaters can be turned 
on at the control panel. The display shows a signal as soon as a heater is active. 
 
Attention: Heaters only for intended use.

 

 
 
 
 
 
 
 
 

Содержание 9904.0000

Страница 1: ...ons Small Size Electroplating Unit DIGITAL II and Digital V Jentner Plating Technology GmbH Johann Staib Strasse 2 75179 Pforzheim Germany Tel 07231 418 094 0 FAX 07231 418 094 77 info jentner de www...

Страница 2: ...tanks PP 3 working and 3 rinsing tanks Dimension 150 x 100 x 150 mm Volume 1 5 litre 1 safety protection cable 1 thermo couple with titanium holder The Digital V includes 8 tanks PP 4 working and 4 r...

Страница 3: ...olt setting voltage Button Charge setting Amin charge Button Time setting of exposure time Button Basin selection of the working tank Button OK save of the set values Button Prog selection of the work...

Страница 4: ...tion for a good conductive contact The required anode material for example stainless steel MOX fine silver platinized titanium depends on each plating bath Please note the information in the data shee...

Страница 5: ...de fuse holder Only micro fuse 4 A slow blow 115 250 V 5 20 mm must be used Attention Make sure there is good ventilation in the work area Rinse water and used chemicals must be disposed of properly P...

Страница 6: ...t Temp Temperature measurement C T1 Temperature 1 T2 Temperature 2 U Voltage measurement Volt I Amperage measurement amp Ti Time Prog Program Charge Deposition measurement Amin example see below Examp...

Страница 7: ...Pd Palladium Pt Platinum Ni Nickel Cu Copper The programs from 1 to 6 are unnamed For each tank up to 3 programs can be installed Approach to programming 1 Turn on main switch 2 Press button progr 3 S...

Страница 8: ...gram the control is done for this process Do as following 1 Press button basin 3 seconds 2 Enter the desired value and basin 3 Press save 4 Leave with OK 5 Press button progr and choose the desired on...

Страница 9: ...II_V_PB en Side 9 of 9 Issue May 2016 Side 9 Operating Instructions DIGITAL II and V Symbols of the display Amin Total charge exceeded Total charge all right Heater on Motion on Unit on Permanent ope...

Отзывы: