Digital II_V_PB.en
Side 5 of 9
Issue May 2016
Side 5 – Operating Instructions DIGITAL II and V
Start up
The delivered power plug which is equipped with protective earth contacts has to be connected with
the power plug port situated on the backside of the machine. Then put the other end of the cable
into an electrical power point 230 V / 50 Hz (120 V / 60 Hz). The unit will be switched on with the
toggle switch at the backside. The power of the rectifier is 15 V / 20 A.
Short-circuit proof / fuse
The unit is short-circuit-proof if there will be short-circuit between cathode and anode.
The fuse is located on the backside of the machine, situated in main connection socket inside fuse
holder. Only micro fuse 4 A (slow blow), 115-250 V ~, 5* 20 mm must be used.
Attention
Make sure there is good ventilation in the work area.
Rinse water and used chemicals must be disposed of properly. Please refer to the legal regulations.
Please observe the instructions of the Safety Data Sheets (MSDS). Your chemical supplier provides
these.
The unit must be turned off after work necessarily!
The heater should never be operated unattended!
Chemicals
The required bath chemicals are available from us or from special producers. Please read the product
information of the manufacturer carefully and follow the instructions.
For more information on machine, bath chemicals, or the respective galvanic process, please
contact us:
Jentner Plating Technology GmbH
Sandweg 20 | 75179 Pforzheim – Germany
Tel.: 07231 – 418 094-0 | FAX 07231 – 418 094-77
|
www.jentner-plating.com