Problem 

Cause 

Corrective Action 

No TV reception on AIR 

No 12VDC power at PCB 

Check  power and ground connections with test light 

  

Blown Fuse 

Check fuse in wall plate and main supply 

  

Bad coax connection 

Check to ensure cables are connected properly at TV & wall plate 

  

Wall Plate Switch in wrong position 

Move switch to AIR position  

  

TV tuner not set to AIR 

Check TV tuner status in on screen menu 

LED Indicator is Off 

No 12VDC power at PCB 

Check  power and ground connections with test light 

  

Blown Fuse 

Check fuse in wall plate and main supply 

  

Shorted coax connection 

Check Antenna coax connection for short 

  

Switch in wrong position 

Check switch position  

No TV reception on Cable 

No 12VDC power at PCB 

Check  power and ground connections with test light 

  

Blown Fuse 

Check fuse in wall plate and main supply 

  

Bad coax connection 

Check to ensure cables are connected properly at TV & wall plate 

  

Wall Plate Switch in wrong position 

Move switch to CABLE position 

  

TV tuner not set to CABLE 

Check TV tuner status in on screen menu 

No power at DC socket 

No 12VDC power at PCB 

Check  power and ground connections with test light 

  

Blown Fuse 

Check fuse in wall plate and main supply 

Содержание ANHD20

Страница 1: ...ANHD20 MOBILE OMNI DIRECTIONAL WIDEBAND ANTENNA Installation and Operation Manual PATENT PENDING...

Страница 2: ...switch should be in the OFF position when connecting disconnecting cables All coaxial cable used should be RG 6U for optimal performance Painting the Antenna is not recommended and may affect perform...

Страница 3: ...ring the fitting is snug Do Not Over tighten Reinstall the plastic housing onto the base Reinstall the lock screw 7 Additional caulking compound may be applied to the outside seam of the base Please n...

Страница 4: ...nects to the Park Cable Input See Figure 6 Do Not Over tighten 3 After connecting all coax cables connect 12VDC wire to the male spade terminal on the circuit board marked with a red dot using a Insul...

Страница 5: ...ntenna If this fuse blows then the antenna will not work Do not connect high current devices 5 Other wall plates do not have the DC receptacle and are fused at 1 Amp to protect the electronics Warning...

Страница 6: ...TV 2 A M F M R adio M ale M otorola to F connector P N AN 3FM T V1 A M PLIFIED SIG N AL JE N SE N S YS TE M LA YO UT A IR O F F C A B LE F U S E W ALL P LAT E A N W P or A NW P12V P rovides pow er to...

Страница 7: ...een menu LED Indicator is Off No 12VDC power at PCB Check power and ground connections with test light Blown Fuse Check fuse in wall plate and main supply Shorted coax connection Check Antenna coax co...

Отзывы: