2
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed
Parts supplied
■
Vent grille
■
Grease filter
■
Grill cartridge
■
Grease container(s)
Parts needed
■
A UL listed or CSA approved strain relief for
⁷⁄₈
" (2.2 cm)
knockout.
■
A UL listed or CSA approved conduit connector for
¹⁄₂
" (1.3 cm) trade-size metal-clad conduit
■
UL listed wire connectors
■
Metal ducting
■
Jenn-Air wall cap
Jenn-Air
®
6" (15.2 cm) Round Surface Wall Cap Damper
Order Part Number A406
Jenn-Air
®
3¼" x 10" (8.3 x 25.4 cm) Surface Wall Cap Damper
Order Part Number A403
To order, see the “Assistance or Service” section of the Use
and Care Guide.
■
Vent clamps
Check local codes. Check existing electrical supply. See
“Electrical Requirements” section.
It is recommended that all electrical connections be made by a
licensed, qualified electrical installer.
Location Requirements
IMPORTANT: Observe all governing codes and ordinances. When
installing cooktop, use minimum dimensions given.
■
To eliminate the risk of burns or fire by reaching over the
heated surface units, cabinet storage space located above the
surface units should be avoided. If cabinet storage is to be
provided, the risk can be reduced by installing a range hood
that projects horizontally a minimum of 5" (12.7 cm) beyond
the bottom of the cabinets.
■
Use the countertop opening dimensions that are given with
these Installation Instructions. Given dimensions are minimum
clearances and provide 0" (0 cm) clearance.
■
Grounded electrical supply is required. See “Electrical
Requirements” section.
■
If cabinet has drawers, drawers will need to be removed and
drawer fronts installed on front of cabinet.
IMPORTANT: An under-counter built-in oven cannot be installed
under this product.
Product Dimensions
30" (76.2 cm) Cooktop
*A minimum clearance of
6¹⁄₄
" (15.9 cm) is recommended for
removal of the grease containers. Installed dimension for the
grease containers is 5
¹⁄₂
" (14.0 cm).
**A minimum clearance of
2
" (5.1 cm) is recommended between
the motor/blower and cabinet for proper cooling.
■
Tape measure
■
Flat-blade screwdriver
■
Phillips head screwdriver
■
Drill
■
Level
■
6" socket extension
■
Marker or pencil
■
Pliers
■
¼" drill bit
■
Jigsaw
■
Ratchet with
³⁄₈
"socket
A. Tie down bolt (on each side of cookop)
B. 30" (76.2 cm)
C. 21
³⁄₄
" (55.3 cm)
D. Grease containers
E. Wiring box cover
F. Blower
A. 6
¹⁄₄
" (15.9 cm)
B. 3
¹⁄₂
" (8.9 cm)
C. Grease containers
D. 2" (5.1 cm)
E. 13
³⁄₄
" (34.9 cm)
F. 11
¹³⁄₁₆
" (30.0 cm)
G. 4" (10.2 cm)
H. 13
¹³⁄₁₆
" (35.1 cm)
B
C
A
F
E
D
A*
B
D**
E
F
G
H
C
C
Содержание W10298937A
Страница 12: ...12 Notes ...