9
Electrical Requirements - U.S.A.
Only
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path and wire gauge are in accordance with local
codes.
Do not use an extension cord.
Be sure that the electrical connection and wire size are adequate
and in conformance with the National Electrical Code,
ANSI/ NFPA 70-latest edition and all local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
WARNING:
Improper connection of the equipment-grounding
conductor can result in a risk of electric shock. Check with a
qualified electrician or service technician if you are in doubt as to
whether the appliance is properly grounded. Do not modify the
power supply cord plug. If it will not fit the outlet, have a proper
outlet installed by a qualified electrician.
Electrical Connection
To properly install your range, you must determine the type of
electrical connection you will be using and follow the instructions
provided for it here.
�
Range must be connected to the proper electrical voltage and
frequency as specified on the model/serial/rating plate. The
model/serial/rating plate is located behind the oven door on the
top right-hand side of the oven frame.
A
A.
Model/serial/rating plate (located behind the oven door on the top
right-hand side of the oven frame)
Range Rating*
Specified Rating of
Power Supply
Cord Kit and
Circuit Protection
120/240 V
120/208 V
Ampere
8.8-16.5 kW
7.8-12.5 kW
40 or 50**
16.6-22.5 kW
12.6-18.5 kW
50
*The NEC calculated load is less than the total connected load
listed on the model/serial/rating plate.
**If connecting to a 50 A circuit, use a 50 A rated cord with kit. For
50 A rated cord kits, use kits that specify use with a nominal 1
3
/
8
"
(3.5 cm) diameter connection opening.
�
A
circuit
breaker
is
recommended.
�
The
range
can
be
connected
directly
to
the
circuit
breaker
box
(or
fused
disconnect)
through
flexible
or
nonmetallic
sheathed,
copper
or
aluminum
cable.
See
the
“Electrical
Connection
-U.S.A.
Only”
section.
�
Allow
at
least
6
ft
(1.8
m)
of
slack
in
the
line
so
that
the
range
can
be
moved
if
servicing
is
ever
necessary.
�
A
UL
listed
conduit
connector
must
be
provided
at
each
end
of
the
power
supply
cable
(at
the
range
and
at
the
junction
box).
�
Wire
sizes
and
connections
must
conform
with
the
rating
of
the
range.
�
The
tech
sheet
is
available
online.
�
This
range
is
equipped
with
a
CSA
International
Certified
Power
Cord
intended
to
be
plugged
into
a
standard
14-50R
wall
receptacle.
Be
sure
the
wall
receptacle
is
within
reach
of
range’s
final
location.
�
Do not use an extension cord.
Electrical Requirements - Canada
Only
WARNING
Electrical Shock Hazard
Electrically ground appliance.
Failure to do so could result in death, fire, or electrical
shock.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path is adequate and wire gauge are in accordance
with local codes.
Be sure that the electrical connection and wire size are adequate
and in conformance with CSA Standard C22.1, Canadian
Electrical Code, Part 1 - latest edition, and all local codes and
ordinances.
A copy of the above code standards can be obtained from:
Canadian Standards Association
178 Rexdale Blvd.
Toronto, ON M9W 1R3 CANADA
�
Check with a qualified electrical installer if you are not sure the
range is properly grounded.