Jenn-Air JXU9130WP1 Скачать руководство пользователя страница 9

9

Complete Preparation

1.

Determine the required height for the home power supply 
cable and drill a 1¼" (3.2 cm) hole at this location.

2.

Run the home power supply cable according to the National 
Electrical Code or CSA Standards and local codes and 
ordinances. There must be enough ½" conduit and wires 
from the fused disconnect (or circuit breaker) box to make 
the connection in the hood’s electrical terminal box.

NOTE:

 Do not reconnect power until installation is complete.

3.

Remove terminal box cover and set aside.

4.

Remove knockout from the top of the vent hood and install 
a UL listed or CSA approved ½" strain relief.

Install Range Hood

1.

Remove the grease filters. See the “Range Hood Care” 
section.

2.

Depending on your installation, remove either top or rear 
rectangular vent knockout. If using round vent, remove top 
rectangular knockout.

Make sure damper pivot is nearest to top/back edge of range 
hood. 

3.

Remove tape from damper flap.

NOTE:

 The 3¼" x 10" (8.3 x 25.4 cm) rectangular damper can 

be installed up to 1" (2.5 cm) on either side of the hood center 
to accommodate off center duct work.

4.

Attach the 3¼" x 10" (8.3 x 25.4 cm) rectangular vent 
connector to the range hood using sheet metal screws.

NOTE:

 If the wall cap is directly behind the 3¼" x 10" (8.3 x 

25.4 cm) rectangular vent connector, check that the damper 
and the wall cap do not interfere with each other. Remove the 
damper from the 3¼" x 10" (8.3 x 25.4 cm) rectangular vent 
connector if they interfere. 

5.

Using 2 or more people, lift the hood into final position. 
Feed enough electrical wire through the ½" UL listed or 
CSA approved strain relief to make connections in the 
terminal box. Tighten the strain relief screws. 

6.

Position the range hood so that the large end of the keyhole 
slots are over the mounting screws. Then, push the hood 
toward the wall (for cabinet mounting) or allow the range 
hood to slide down to the marked mounting height (for wall 
mounting) so that the screws are in the neck of the slots. 
Tighten the mounting screws, making sure the screws are 
in the narrow neck of slots. (For wall mount, check that the 
hood is level). 

7.

Connect ventwork to hood. Seal joints with clamps to make 
secure and airtight.

8.

Check that back draft dampers work properly.

Make Electrical Connection

1.

Disconnect power. 

2.

Use UL listed wire connectors and connect white wires (A) 
together.

A. Vent knockouts

A. Top venting
B. Sheet metal screws

C. Hinge pin
D. Vent knockouts

E. Rear venting

A

A

B

C

D

C

B

E

A. White wires
B. Black wires

C. UL listed wire connector
D. Green (or bare) and yellow-green ground wire

E. Home power supply cable

F. UL listed or CSA approved ½" strain relief

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Replace all parts and panels before operating.

Failure to do so can result in death or electrical shock.

A

B

C

D

E

F

Содержание JXU9130WP1

Страница 1: ... 536 6247 or visit our website at www jennair com In Canada call 1 800 JENNAIR 1 800 536 6247 or visit our website at www jennair ca Instructions d installation et Guide d utilisation et d entretien Au Canada pour assistance installation ou service composez le 1 800 JENNAIR 1 800 536 6247 ou visitez notre site web à www jennair ca Table of Contents Table des matières 2 LI3V3B W10274318B IMPORTANT ...

Страница 2: ... HOTTE 25 Nettoyage 25 SCHÉMA DE CÂBLAGE 26 ASSISTANCE OU SERVICE 27 Au Canada 27 Accessoires 27 GARANTIE 28 RANGE HOOD SAFETY You can be killed or seriously injured if you don t immediately You can be killed or seriously injured if you don t follow All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instruc...

Страница 3: ...3 IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS ...

Страница 4: ...e installer s responsibility to comply with installation clearances specified on the model serial rating plate The model serial rating plate is located behind the left filter on the rear wall of the vent hood Canopy hood location should be away from strong draft areas such as windows doors and strong heating vents Cabinet opening dimensions that are shown must be used Given dimensions provide mini...

Страница 5: ... as close as possible to where the vent system enters the heated portion of the house Makeup Air Local building codes may require the use of makeup air systems when using ventilation systems greater than specified CFM of air movement The specified CFM varies from locale to locale Consult your HVAC professional for specific requirements in your area Venting Methods This canopy hood is factory set f...

Страница 6: ...s aluminum wiring follow the procedure below 1 Connect a section of solid copper wire to the pigtail leads 2 Connect the aluminum wiring to the added section of copper wire using special connectors and or tools designed and UL listed for joining copper to aluminum Follow the electrical connector manufacturer s recommended procedure Aluminum copper connection must conform with local codes and indus...

Страница 7: ...ng access hole See Step 2 for wiring hole location instructions 1 Determine and clearly mark a vertical centerline on the wall and cabinet in the area the vent opening will be made 2 To wire through top Mark a line distance A from the left of the centerline on the underside of the cabinet Mark the point on this line that is 7 20 0 cm from back wall Drill a 1 3 2 cm diameter hole through the cabine...

Страница 8: ... 2 cm and a suggested maximum of 36 91 4 cm above the range to the bottom of the hood Mark a reference line on the wall 3 Using 2 or more people center the hood on the vertical centerline then align the bottom of the hood with the horizontal reference line marked on the wall 4 Mark centers of the fastener locations to the wall Set range hood aside on a covered surface IMPORTANT All screws must be ...

Страница 9: ...he damper and the wall cap do not interfere with each other Remove the damper from the 3 x 10 8 3 x 25 4 cm rectangular vent connector if they interfere 5 Using 2 or more people lift the hood into final position Feed enough electrical wire through the UL listed or CSA approved strain relief to make connections in the terminal box Tighten the strain relief screws 6 Position the range hood so that t...

Страница 10: ...l minutes after the cooking is complete to clear all smoke and odors from the kitchen The hood controls are located on the right hand underside of the range hood Range Hood Controls Operating the lights 1 Turn the light switch to the Night position to use the range hood lights as a night light 2 Turn the light switch to the High position to turn the range hood lights On 3 Turn the light switch to ...

Страница 11: ...al grease filters as needed in a dishwasher or hand wash in a hot detergent solution to clean To Reinstall Metal Grease Filters 1 Grasp filter handles and place rear of filter into rear track 2 Push down on the rear handle and set the front of the grease filter into the front track to secure 3 Repeat for each filter Replacing a Halogen Lamp Turn off the range hood and allow the halogen lamp to coo...

Страница 12: ...12 WIRING DIAGRAM VARISTOR BK BK BK BK BK WH WH WH WH BU BK GY RD WH BU BK WH WH BU BU GY GY BK BK RD RD YL YL BR BR YL GN YL GN WH BK WH BK YL GN BK BK WH WH YL GN YL GN WH BK BU ...

Страница 13: ...liances with any questions or concerns at Jenn Air Brand Home Appliances Customer eXperience Center 553 Benson Road Benton Harbor MI 49022 2692 Please include a daytime phone number in your correspondence In Canada Call the Whirlpool Canada LP Customer eXperience Centre toll free at 1 800 JENNAIR 1 800 536 6247 or visit our website at www jennair ca Our consultants provide assistance with Scheduli...

Страница 14: ...ers preservation solutions etc 5 Defects or damage caused by the use of non genuine Jenn Air parts or accessories 6 Conversion of products from natural gas or L P gas 7 Damage from accident misuse abuse fire floods acts of God or use with products not approved by Jenn Air 8 Repairs to parts or systems to correct product damage or defects caused by unauthorized service alteration or modification of...