INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation. 

Read and follow the instructions provided with any tools listed 

here.

Tools needed

 

Level

 

Drill

 

Drill with 1¼" (3.0 cm), 3/16" (4.8 mm), 1/8" (3.0 mm), and 

5/16" (7.9 mm) drill bits

 

Pencil

 

Wire stripper or utility knife

 

Tape measure or ruler

 

Pliers

 

Caulking gun and weatherproof caulking compound

 

Vent clamps

 

Jigsaw or keyhole saw

 

Flat-blade screwdriver

 

Metal snips

 

Phillips screwdriver

 

Metric hex key set

Parts needed

 

Home power supply cable

 

1/2" (1.3 cm) UL listed or CSA approved strain relief

 

3 UL listed wire connectors

 

1 wall or roof cap

 

Metal vent system

Parts supplied

Remove parts from packages. Check that all parts are included.

 

Hood canopy assembly with ventilator and light bulbs 

installed

 

3¼" x 10" (8.3 x 25.4 cm) rectangular vent connector

 

2 metal grease filters for 30" (76.2 cm) model

 

3 metal grease filters for 36" (91.4 cm) model

 

T20

®

 Torx

®†

 adapter

 

4 - 5 x 45 mm mounting screws

 

6 - 4.5 x 13 mm screws

 

3 - 4 x 8 mm screws

 

4 - 10 x 50 wall anchors

Location Requirements

IMPORTANT: 

Observe all governing codes and ordinances.

Have a qualified technician install the range hood. It is the 

installer's responsibility to comply with installation clearances 

specified on the model/serial rating plate. The model/serial rating 

plate is located behind the left filter on the rear wall of the vent 

hood.
Canopy hood location should be away from strong draft areas, 

such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used. 

Given dimensions provide minimum clearance.
Grounded electrical outlet is required. See “Electrical 

Requirements” section.
The canopy hood is factory set for venting through the roof or 

wall.
All openings in ceiling and wall where canopy hood will be 

installed must be sealed.

For Mobile Home Installations

The installation of this range hood must conform to the 

Manufactured Home Construction Safety Standards, Title 24 

CFR, Part 328 (formerly the Federal Standard for Mobile Home 

Construction and Safety, Title 24, HUD, Part 280) or when such 

standard is not applicable, the standard for Manufactured Home 

Installation 1982 (Manufactured Home Sites, Communities and 

Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local 

codes.

Product Dimensions

Front View

12"

(30.5 cm)

2" 

(5.1 cm)

30" (76.2 cm)
36" (91.4 cm)

23" (58.4 cm)

10" 

(25.4 cm)

³⁄₈

"

(1.0 cm)

(6.5 cm)

2

⁹⁄₁₆

7½"

(19.0 cm)

29

¹⁄₈

" (74.0 cm): 30" (76.2 cm) models 

35

¹⁄₈

" (89.2 cm): 36" (91.4 cm) models 

†®TORX and T20 are registered trademarks of Acument Intellectual Properties, LLC.

Содержание JXU913

Страница 1: ...536 6247 or visit our website at www jennair com In Canada call 1 800 JENNAIR 1 800 536 6247 or visit our website at www jennair ca Instructions d installation et Guide d utilisation et d entretien Au...

Страница 2: ...ATI RES RANGE HOOD SAFETY 2 INSTALLATION REQUIREMENTS 4 Tools and Parts 4 Location Requirements 4 Venting Requirements 5 Electrical Requirements 6 INSTALLATION INSTRUCTIONS 7 Prepare Location 7 Instal...

Страница 3: ...en whose physical sensory or mental capacities are different or impaired or who lack the necessary experience or knowledge expertise to do so unless such persons are supervised or are trained to opera...

Страница 4: ...od It is the installer s responsibility to comply with installation clearances specified on the model serial rating plate The model serial rating plate is located behind the left filter on the rear wa...

Страница 5: ...as possible to where the vent system enters the heated portion of the house Makeup Air Local building codes may require the use of makeup air systems when using ventilation systems greater than speci...

Страница 6: ...d it is recommended that a qualified electrician determine that the ground path is adequate A copy of the above code standards can be obtained from National Fire Protection Association 1 Batterymarch...

Страница 7: ...access hole See Step 2 for wiring hole location instructions 1 Determine and clearly mark a vertical centerline on the wall and cabinet in the area the vent opening will be made 2 To wire through top...

Страница 8: ...76 2 cm and a suggested maximum of 36 91 4 cm above the range to the bottom of the hood Mark a reference line on the wall 3 Using 2 or more people center the hood on the vertical centerline then align...

Страница 9: ...the damper and the wall cap do not interfere with each other Remove the damper from the 3 x 10 8 3 x 25 4 cm rectangular vent connector if they interfere 5 Using 2 or more people lift the hood into fi...

Страница 10: ...cooking is complete to clear all smoke and odors from the kitchen The hood controls are located on the right hand underside of the range hood Range Hood Controls Operating the lights 1 Turn the light...

Страница 11: ...ove 2 3 wash in a hot detergent solution to clean To Reinstall Metal Grease Filters 1 2 Push down on the rear handle and set the front of the grease 3 Replacing a LED Lamp Turn off the range hood and...

Страница 12: ...SE1YJB LED LED 12 WIRING DIAGRAM VARISTOR BK BK BK BK BK WH WH WH WH BU BK GY RD WH BU BK WH WH BU BU GY GY BK BK RD RD YL YL BR BR YL GN YL GN WH BK WH BK YL GN BK BK WH WH YL GN YL GN WH BK BU...

Страница 13: ...553 Benson Road Benton Harbor MI 49022 2692 Please include a daytime phone number in your correspondence In Canada Call the Whirlpool Canada LP Customer eXperience Centre toll free at 1 800 JENNAIR 1...

Страница 14: ...n cas de non respect des instructions Votre s curit et celle des autres est tr s importante Nous donnons de nombreux messages de s curit importants dans ce manuel et sur votre appareil m nager Assurez...

Страница 15: ...e vide du b timent comme une cavit murale un plafond un grenier un vide sanitaire ou un garage AVERTISSEMENT POUR R DUIRE LE RISQUE D INCENDIE UTILISER UNIQUEMENT DES CONDUITS M TALLIQUES AVERTISSEMEN...

Страница 16: ...ORTANT Observer les dispositions de tous les codes et r glements en vigueur Confier l installation de la hotte un technicien qualifi C est l installateur qu incombe la responsabilit de respecter les d...

Страница 17: ...les brides de serrage Le circuit d vacuation doit comporter un clapet anti reflux Si la bouche de d charge murale ou par le toit comporte un clapet ne pas utiliser le clapet fourni avec la hotte de c...

Страница 18: ...mur Voir la section Installation de la hotte pour les d tails pour l installation d un clapet anti reflux REMARQUE On d conseille l emploi d un conduit flexible Un conduit flexible peut susciter une...

Страница 19: ...l appareil est situ e derri re le filtre sur la paroi arri re de la hotte Le calibre des conducteurs doit tre conforme aux exigences du National Electrical Code de la plus r cente dition de la norme...

Страница 20: ...une scie guichet pour d couper l ouverture rectangulaire pour le passage du conduit d vacuation 4 R p ter les tapes 1 3 pour la face inf rieure du sommet du placard D charge travers le mur sous un pla...

Страница 21: ...ion Installer le syst me d vacuation avant la hotte Voir la section Exigences concernant l vacuation Achever la pr paration 1 D terminer la hauteur appropri e pour le cordon d alimentation du domicile...

Страница 22: ...ur un montage sur le mur pour que les vis soient dans la partie troite des trous de fixation des vis Serrer les vis de montage en s assurant que les vis sont dans la partie troite des trous de fixatio...

Страница 23: ...trace d odeur de cuisson vapeur ou fum e Les commandes de la hotte sont situ es sous celle ci du c t droit Commandes de la hotte de cuisini re Pour faire fonctionner les lampes 1 Placer le commutateu...

Страница 24: ...mpe DEL Interrompre l alimentation de la hotte attendre le refroidissement de la lampe DEL Pour viter d endommager ou de r duire la long vit de l ampoule neuve ne pas toucher l ampoule avec les doigts...

Страница 25: ...A DE C BLAGE JA VE N JA VE BL BL JA VE N BL N N BL N BU BU BU GRIS GRIS N N R R BL BL JA JA MAR MAR JA VE JA VE N BL N N BL BL BL N N BL LAMPE CONTACTEUR BU CONTACTEUR MOTEUR N BU N GRIS R BL VARISTAN...

Страница 26: ...r la garantie des produits et fournir un service apr s la garantie partout au Canada d appareils m nagers R f rences aux concessionnaires locaux JennAir Renseignements pour l installation Proc d s d u...

Страница 27: ...27 REMARQUES...

Страница 28: ...LI3V3D W11374533A 06 19 Printed in Mexico Imprim au Mexique 2019 JennAir Used under license in Canada All rights reserved Utilis sous licence au Canada Tous droits r serv s...

Отзывы: