Jenn-Air JXI8536DS Скачать руководство пользователя страница 11

11

RANGE HOOD USE

The range hood is designed to remove smoke, cooking vapors and 
odors from the cooktop area. For best results, start the hood 
before cooking and allow it to operate several minutes after the 
cooking is complete to clear all smoke and odors from the kitchen.
The range hood controls are located on the front side of the canopy.

Control Panel

Controls and Features

NOTES:

To activate the controls, press and release the desired button.

The control feature button will be lit when a control feature is 
turned On.

Sleep Mode

The range hood automatically enters Sleep Mode when not in 
use. After 10 minutes of no range hood activity, all of the control 
button lights will turn Off. To deactivate Sleep Mode, press any 
button.

Auto Sense

Auto Sense allows the range hood fan to turn on automatically 
when it senses heat higher than its allowable temperature limit. 
When Auto Sense is On, the fan speed will increase or decrease 
based on the temperature Auto Sense is measuring.
Auto Sense can be manually increased by pressing a higher fan 
speed. The fan will run at the selected speed for 10 minutes 
before returning to the speed selected for Auto Sense.
If Auto Sense is On, the Auto button light will turn Off and go into 
Sleep Mode when the vent hood is not in use. If the vent hood is 
turned On by the consumer or by Auto Sense, the Auto button 
light will turn On. 

To set Auto Sense:

Press AUTO.

To Select Auto Sense Cooktop Type:

NOTE:

 The range hood is factory-set for the gas cooktop 

mode.

Press and hold AUTO for 5 seconds to switch between the 
gas cooktop and electric cooktop modes.

The Auto button light will flash 5 times when the range hood 
is changed to the electric cooktop mode. Auto Sense is now 
set to work with electric cooktops and ranges.

The Auto button light will flash 3 times when the range hood 
is changed to the gas cooktop mode. Auto Sense is now set 
to work with gas cooktops and ranges.

Changing the cooktop type will change the temperature limit 
for Auto Sense to turn On. When the range hood senses a 
high enough temperature, the fan will start automatically. 
When the temperature drops below the set temperature limit, 
the fan will stop automatically. The Auto button light will turn 
Off after the range hood enters Sleep Mode, but Auto Sense 
is still active.

To Deactivate Auto Sense:

If the Auto button is lit, press AUTO once to deactivate Auto 
Sense. The Auto button light will turn Off.

If Auto Sense is in Sleep Mode, press AUTO once to 
deactivate Sleep Mode and turn the Auto button light On. 
Press AUTO again to deactivate Auto Sense and turn Off the 
Auto button light.

Auto Sense will automatically turn off after 2 hours of no 
activation of the Auto Sense system. To reset Auto Sense, 
press AUTO.

Manual Vent Functions

A. Louver holes (non-vented 

[recirculating] installations only)

B. Upper duct covers

C. Lower duct covers
D. LED lights (4)

E. Metal grease filters 

(located behind the 
perimetic cover)

F. Perimetic cover

G. Canopy

H. Control panel

A

B

C

D

D

E

F

G

H

Fan Speeds

Low

Press LOW to turn the fan on at Low speed.

Med

Press MED to turn the fan on at Medium speed.

Hi

Press HI to turn the fan on at High speed.

Boost

Press BOOST to turn the fan on at the highest 
speed. Boost will automatically turn Off after 
10 minutes and the fan will switch to High 
speed.

Содержание JXI8536DS

Страница 1: ...nnair com In Canada call 1 800 JENNAIR 1 800 536 6247 or visit our website at www jennair ca Instructions d installation et Guide d utilisation et d entretien Au Canada pour assistance installation ou...

Страница 2: ...OTTE 28 Nettoyage 28 SCH MA DE C BLAGE 29 ASSISTANCE OU SERVICE 30 Au Canada 30 Accessoires 30 GARANTIE 31 RANGE HOOD SAFETY You can be killed or seriously injured if you don t immediately You can be...

Страница 3: ...3 IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS...

Страница 4: ...model serial rating plate The model serial rating plate is located behind the left filter on the rear wall of the vent hood Canopy hood location should be away from strong draft areas such as windows...

Страница 5: ...to seal exterior wall or roof opening around the cap The size of the vent should be uniform Cold Weather Installations An additional back draft damper should be installed to minimize backward cold air...

Страница 6: ...ark Quincy MA 02169 7471 CSA International 8501 East Pleasant Valley Road Cleveland OH 44131 5575 A 120 volt 60 Hz AC only 15 amp fused electrical circuit is required If the house has aluminum wiring...

Страница 7: ...power supply cable and drill a 1 3 cm diameter hole for wire access 2 Run wire through the home power supply cable according to the National Electrical Code or CSA Standards and local codes and ordin...

Страница 8: ...Use caulk to seal all openings Non Vented Recirculating Installation 1 Attach the air deflector to the upper horizontal support using 4 mounting screws 2 Measure the length of 6 15 2 cm duct needed to...

Страница 9: ...ame The larger hole in the flanges of the upper duct cover must be outside the smaller hole in the mating flange of the other upper duct cover 2 Secure the upper duct covers together with two 3 5 x 6...

Страница 10: ...over the plastic clip to secure the lower duct covers together at the bottom 7 Secure the lower duct covers together at the top using 2 plastic clips Use one plastic clip on each side 8 Secure the lo...

Страница 11: ...tween the gas cooktop and electric cooktop modes The Auto button light will flash 5 times when the range hood is changed to the electric cooktop mode Auto Sense is now set to work with electric cookto...

Страница 12: ...Cleaning Method Liquid detergent soap and water or all purpose cleanser Wipe with damp soft cloth or nonabrasive sponge then rinse with clean water and wipe dry Metal Grease Filter 1 Open the stainle...

Страница 13: ...or Specifications Power Supply Frequency Power Absorbtion 120 VAC 60 HZ 420 W Motor Resistance Blue Black Blue Grey Blue Red Blue White 9 8 14 3 18 21 6 SE130B RD M 3 2 1 4 5 6 7 8 9 BU YL GN BR YL WH...

Страница 14: ...h any questions or concerns at Jenn Air Brand Home Appliances Customer eXperience Center 553 Benson Road Benton Harbor MI 49022 2692 Please include a daytime phone number in your correspondence In Can...

Страница 15: ...light bulbs batteries air or water filters preservation solutions etc 5 Conversion of products from natural gas or L P gas 6 Damage from accident misuse abuse fire floods acts of God or use with prod...

Страница 16: ...re appareil m nager Assurez vous de toujours lire tous les messages de s curit et de vous y conformer AVERTISSEMENT DANGER Voici le symbole d alerte de s curit Ce symbole d alerte de s curit vous sign...

Страница 17: ...ue d incendie et vacuer ad quatement les gaz veiller acheminer l air aspir par un conduit jusqu l ext rieur ne pas d charger l air aspir dans un espace vide du b timent comme une cavit murale un plafo...

Страница 18: ...ponsabilit de respecter les distances de s paration exig es sp cifi es sur la plaque signal tique de l appareil La plaque signal tique de l appareil est situ e derri re le filtre de gauche sur la paro...

Страница 19: ...uniquement Un conduit en m tal rigide est recommand Ne pas utiliser de conduit de plastique ou d aluminium Le syst me d vacuation doit comporter un clapet Si la bouche de d charge murale ou par le toi...

Страница 20: ...e peut causer une r tropression et des turbulences de l air ce qui r duit consid rablement la performance La sortie l ext rieur du circuit d vacuation peut se faire travers le toit ou travers un mur P...

Страница 21: ...e un d gagement suffisant dans le plafond pour le conduit d vacuation La hotte doit tre install e 24 61 cm min des surfaces de cuisson lectriques ou 27 68 6 cm min des surfaces de cuisson au gaz et un...

Страница 22: ...er Assemblage et installation de la hotte 1 Installer le raccord de transition au sommet de la hotte s il a t enlev pour exp dition avec 2 vis de t lerie de 3 5 x 9 5 mm 2 Positionner les 4 supports v...

Страница 23: ...o tier de connexion 3 ter l opercule arrachable du bo tier de connexion et installer un serre c ble de homologation UL ou CSA 4 Acheminer le cordon d alimentation du domicile travers le serre c ble da...

Страница 24: ...de support Le trou le plus gros sur les rebords de la partie sup rieure du cache conduit doit se trouver l ext rieur du trou le plus petit sur le rebord en contact de l autre partie sup rieure du cach...

Страница 25: ...ds de la partie sup rieure du cache conduit S assurer que les parties inf rieures avant et arri re des cache conduits communiquent correctement REMARQUE Lors de l assemblage de la partie inf rieure ar...

Страница 26: ...que met la hotte en marche automatiquement lorsqu elle d tecte une chaleur sup rieure la limite de temp rature permise Lorsque la fonction Auto Sense d tection automatique est activ e la vitesse du ve...

Страница 27: ...en continu Apr s 15 minutes le ventilateur s teint automatiquement 2 Lorsque la minuterie du ventilateur est en marche appuyer encore une fois sur le bouton correspondant la vitesse de ventilateur d...

Страница 28: ...llique vers le haut et rel cher la poign e pour embo ter le loquet 7 R p ter les tapes 1 5 pour l autre filtre 8 Fermer le panneau en acier inoxydable Fixer en engageant les 2 pitons dans les loquets...

Страница 29: ...eur de vitesse automatique Interface utilisateur JA BU BU BL BL N Del Del N R N Rampe de Del Rampe de Del R R N N BU BL BL N Del Del N R N R N N R N R R JA VE MAR JA Nue Ph Terre JA VE Filtre interf r...

Страница 30: ...la garantie des produits et fournir un service apr s la garantie partout au Canada Caract ristiques et sp cifications de notre gamme compl te d appareils m nagers R f rences aux concessionnaires locau...

Страница 31: ...utions de conservation etc 5 Conversion de votre produit du gaz naturel ou du gaz de p trole liqu fi 6 Dommages caus s par accident m susage abus incendie inondations catastrophe naturelle ou l utilis...

Страница 32: ...W10674115C 2014 Jenn Air Used under license in Canada All rights reserved Utilis sous licence au Canada Tous droits r serv s 9 14 Printed in Mexico Imprim au Mexique...

Отзывы: