6
■
The water shutoff should be located in the base cabinet on
either side of the refrigerator or some other easily accessible
area. If the water shutoff valve is not in the cabinets, the
plumbing for the water line can come through the floor. See
“Water Supply Requirements” for more information.
IMPORTANT:
■
Flooring under refrigerator must be at same level as the
room. Face of cabinetry must be plumb.
■
The width of the opening (Width A), must be as specified
for your model, for at least 2" (5.08 cm) back from the face
of the cabinet. If your opening does not meet this
requirement, you will need to make modifications.
Electrical Requirements
Before you move your refrigerator into its final location, it is
important to make sure you have the proper electrical connection.
Recommended Grounding Method
A 115 Volt, 60 Hz., AC only, 15- or 20-amp fused, grounded
electrical supply is required. It is recommended that a separate
circuit serving only your refrigerator be provided. Use an outlet
that cannot be turned off by a switch. Do not use an
extension cord.
IMPORTANT: If this product is connected to a GFCI (Ground Fault
Circuit Interrupter) protected outlet, nuisance tripping of the
power supply may occur, resulting in loss of cooling. Food quality
and flavor may be affected. If nuisance tripping has occurred, and
if the condition of the food appears poor, dispose of it.
NOTE: Before performing any type of installation, cleaning, or
removing a light bulb, remove the top grille and turn the master
power switch to OFF or disconnect power at the circuit breaker
box.
When you are finished, turn ON the master power switch or
reconnect power at the circuit breaker box. Then reset the control
to the desired setting.
Model
Width A (as shown above)
42
48
42" (106.7 cm)
48" (121.9 cm)
Installation Type
Depth B (as shown above)
Standard Flush
(new installation)
25" (63.5 cm) minimum
Retrofit Installations
24" (60.9 cm) minimum
80" - 90"
(203-229 cm)
4"
(10.2 cm)
84" (213.4 cm)
to bottom of solid soffit
1"
(2.54 cm)
77"
(196 cm)
6"
(15.2 cm)
6"
(15.2 cm)
A
Width
(see chart following)
B
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING