background image

3

Cabinet Dimensions

27" (68.6 cm) and 30" (76.2 cm) Microwave Ovens

Minimum Installation Clearances

For proper installation, the following minimum clearances must 

exist above and below the cabinet opening.

Installation Above Single Built-In Oven

Approved models: JJW2430, JJW2427, JMW2427, JJW3430

Electrical Requirements

If codes permit and a separate ground wire is used, it is 

recommended that a qualified electrical installer determine 

that the ground path and wire gauge are in accordance with 

local codes.
Check with a qualified electrical installer if you are not sure 

the oven is properly grounded.
This oven must be connected to a grounded metal, permanent 

wiring system.
Be sure that the electrical connection and wire size are adequate 

and in conformance with the National Electrical Code, ANSI/

NFPA 70 – latest edition or CSA Standards C22.1-94, Canadian 

Electrical Code, Part 1 and C22.2 No. O-M91 – latest edition, 

and all local codes and ordinances.
A copy of the above code standards can be obtained from:

National Fire Protection Association 

1 Batterymarch Park 

Quincy, MA 02169-7471

CSA International 

8501 East Pleasant Valley Road 

Cleveland, OH 44131-5575

Electrical Connection

To properly install your microwave oven, you must determine 

the type of electrical connection you will be using and follow 

the instructions provided for it here.

 

Microwave oven must be connected to the proper electrical 

voltage and frequency as specified on the model/serial/rating 

plate. The model/serial/rating plate is located underneath the 

control panel along the oven vent.

 

The microwave oven rated 120-/240-volt, 20-amp, has 

4 wires (L1, L2, N, and G) in the flex conduit, and should be 

connected to a 20-amp maximum-rated circuit, overcurrent 

protected on both the L1 and L2 circuits.

 

A time-delay fuse or circuit breaker is recommended.

 

Flexible cable from the microwave oven should be 

connected directly to the junction box.

 

Do not cut the conduit. The length of conduit provided is for 

serviceability of the microwave oven.

A

B

C

D

E

F

G

27" (68.6 cm) models

A.  27" (68.6 cm) min. 

cabinet width

B. 19

7

/

8

" (50.3 cm) from bottom 

of cutout to bottom of upper 

cabinet door

C.  40" (101.6 cm) bottom of 

cutout to floor (recommended)

D. 25

1

/

2

" (64.8 cm) cutout width

E. 1

1

/

2

" (3.8 cm) min. bottom of 

cutout to top of cabinet door

F. 17

5

/

8

" (44.7 cm) recommended 

cutout height (will fit cutout 

height from 17

3

/

8

" [44.1 cm] 

to 17

3

/

4

" [45.1 cm])

G. 21

7

/

8

" (55.5 cm) min. 

cutout depth

30" (76.2 cm) models

A.  30" (76.2 cm) min. 

cabinet width

B. 19

7

/

8

" (50.3 cm) from bottom 

of cutout to bottom of upper 

cabinet door

C.  40" (101.6 cm) bottom of 

cutout to floor (recommended)

D. 28

1

/

2

" (72.4 cm) cutout width

E. 1

1

/

2

" (3.8 cm) min. bottom of 

cutout to top of cabinet door

F. 17

5

/

8

" (44.7 cm) recommended 

cutout height (will fit cutout 

height from 17

3

/

8

" [44.1 cm] 

to 17

3

/

4

" [45.1 cm])

G. 21

7

/

8

" (55.5 cm) min. 

cutout depth

2 3/16"

(5.5 cm)

1"

(2.5 cm)

from top

of oven

A

B

A.  Upper cabinet
B.  Lower single oven

For a permanently connected microwave oven:

The microwave oven must be connected to a grounded, 
metallic, permanent wiring system, or an equipment 
grounding conductor should be run with the circuit 
conductors and connected to the equipment grounding 
terminal or lead on the microwave oven.

GROUNDING INSTRUCTIONS

SAVE THESE INSTRUCTIONS

A

A.  Model/serial/rating plate