background image

7

Electrical Wiring Information

This appliance is equipped with a grounded type power
cord. A grounded outlet must be provided. It is
recommended, for convenience, the outlet be located
(with reference to figure 6) as in A or B, below:

A. If no other appliance is to be installed below this

appliance: within either the shaded area or the cross
hatched area shown in figure 6.

B. If a Model JJW8530, JJW9530, W30400P, or JJW8130

Electric Wall Oven is to be installed below this
appliance, either:

1. within the cross hatched area of figure 6, or,

2. within an adjacent cabinet.

If a wall oven is to be installed below this appliance and
the counter units outlet is to be mounted within the cross
hatched area of figure 6:

1. The cabinet’s lower front panel, below the oven,

must be made removable for access to the outlet.

2. A clearance hole for the power cord’s plug (1-1/4

²

(3.18 cm) dia is recommended) must be provided
through the oven’s floor support shelf and, if
necessary, through the slats supporting the shelf.
The clearance hole should be located as near as
practical to the rear of the shelf.

If the outlet is to be mounted in either a left or right
adjacent cabinet, a clearance hole, as described above,
must be provided in the dividing wall between the
cabinets. Figure 4; page 5, illustrates a typical (left side)
dividing wall. The clearance hole (not shown in figure 4)

can be located as is convenient in this left wall or in the
corresponding right wall.

In planning any installation, note that the free length of
this appliance’s power cord, extending beyond a point
3-3/4

²

(9.53 cm) left of the nominal center of the rear wall

of the burner box, when viewed from the front of the unit,
is approximately 46

²

(117 cm).

User may experience occasional circuit tripping if Ground
Fault Circuit Interrupter (GFCI) outlet or breaker is in use.

Electrical Grounding Instructions

This appliance is equipped with a (three-prong)
grounding plug for your protection against shock
hazard and should be plugged directly into a
properly grounded receptacle. Do not cut or remove
the grounding prong from this plug.

THIS APPLIANCE MUST BE DISCON-
NECTED FROM ITS ELECTRICAL SUPPLY
AT THE WALL RECEPTACLE BEFORE
SERVICING THE APPLIANCE.

FIGURE 6

3 1/2

²

(8.89 cm) WIDE

SLATS WHEN A WALL

OVEN IS INSTALLED

BELOW 30

²

MODEL

4

²

MAX.

10.16 cm

37 3/16

²

94.46 cm

29 3/8

²

74.61 cm

3 13/16

²

9.7 cm

CABINET BOTTOM

Содержание JGC9430

Страница 1: ...AL WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE MAINTENANCE OR USE OF RANGE CAN RESULT IN SERIOUS INJURY OR PROPERTY DAMAGE NOTICE TO INSTALLER Leave these instructions with the applian...

Страница 2: ...f the countertop laminate 4 Countertop must be supported within 3 7 62 cm of cutout Installing Cabinetry Over Your Jenn Air Cooktop A 30 76 2 cm minimum vertical clearance between cooking surface and...

Страница 3: ...d a length of three 3 feet 36 inches All supply piping except as noted should use common National Pipe Thread N P T For all pipe connections use an approved pipe joint compound resistant to the action...

Страница 4: ...e appliance in its counter cutout Make the gas connection to the inlet of the appliance pressure regulator with 1 2 NPT male pipe threads Install a manual shut off valve in an accessible location in t...

Страница 5: ...an accessible location in the gas line ahead of the appliance regulator and external to the appliance for the purpose of turning on or shutting off gas to the appliance Make additional pipe connectio...

Страница 6: ...ubbles appearing around fittings and connections will indicate a leak If a leak appears turn off supply line gas shut off valve tighten connections turn on the supply line gas shut off valve and retes...

Страница 7: ...elf If the outlet is to be mounted in either a left or right adjacent cabinet a clearance hole as described above must be provided in the dividing wall between the cabinets Figure 4 page 5 illustrates...

Страница 8: ...d C A REPLACE ALL ORIFICE SPUDS Step 1 Remove the grates and burner caps Step 2 Remove burner base by removing 2 screws See figure 7 Step 3 Firmly press 9 32 or 7mm nut driver over the orifice spud fi...

Страница 9: ...W FLAME ADJUSTMENT See figure 13 This appliance is shipped from the factory with low and high flame settings adjusted for use with natural gas To set for use with LP proceed as follows 1 Remove contro...

Страница 10: ...ower and gas must be turned off prior to conversion If this appliance has been converted for use with LP gas each of the following modifications must be performed to convert the unit back to natural g...

Страница 11: ...NATURAL GAS LP GAS BTU HR FIGURE 17 BURNER LOCATION Hi Lo Right Front 15 000 15 000 2000 2000 Right Rear 9 200 9 100 1450 1550 Left Front 5 000 4 000 650 850 Left Rear 10 500 9 100 1450 1550 Burner I...

Страница 12: ...est equipado para el tipo de gas que se suministrar Consulte la placa de datos que se encuentra en el lado de abajo de la caja de los quemadores para obtener esta informaci n No trate de convertir est...

Страница 13: ...e la cocina debe estar apoyado a menos de 3 7 62 cm del corte del hueco Instalaci n de los gabinetes por encima de la superficie para cocinar Jenn Air A 30 76 2 cm de espacio vertical m nimo entre la...

Страница 14: ...Toda la tuber a de suministro excepto seg n se especifique deber usar tuber a de rosca est ndar National Pipe Thread NPT En todas las conexiones de la tuber a use un compuesto de uniones aprobado que...

Страница 15: ...2 NTP Instale una v lvula de cierre manual en un lugar accesible en la tuber a de gas m s adelante del regulador de presi n y afuera del electrodom stico con el fin de cerrar y abrir el gas al aparato...

Страница 16: ...ierre a la fuente del suministro de gas Aseg rese de que todas las conexiones de uni n de la tuber a est n a prueba de gas FIGURA 4 ILUSTRACI N DE LA TUBER A DEL SUMINISTRO DE GAS HORNO DE PARED INSTA...

Страница 17: ...a fuga cierre la v lvula de la tuber a de suministro de gas apriete las conexiones abra la v lvula de cierre de la tuber a de gas y vuelva a revisar si hay fugas Nunca revise si existen fugas con una...

Страница 18: ...te adyacente izquierdo o derecho debe proveerse un orificio libre como se describe anteriormente en la pared divisoria entre los gabinetes La figura 4 p gina 5 ilustra una pared divisoria t pica lado...

Страница 19: ...figura 7 Paso 3 Oprima con firmeza una llave para tuercas de 9 32 7 mm sobre los puntales de orificio figura 7 y afloje los puntales gir ndolos en sentido contrario al de las manecillas del reloj Leva...

Страница 20: ...OS BORDES DEL DISCO PARA VOLVER A COLOCAR EL PASADOR EN LA TAPA APLIQUE PRESI N HACIA LOS LADOS CON EL DEDO PARA QUITAR EL PASADOR DE LA TAPA TAPA Y PASADOR DEL CONVERTIDOR C AJUSTE DE LA LLAMA BAJA V...

Страница 21: ...ERTENCIA Si este electrodom stico se ha convertido para usarse con gas LP deben realizarse cada una de las siguientes modificaciones para convertir la unidad de nuevo a gas natural A COLOQUE DE NUEVO...

Страница 22: ...0 Posterior derecho 9 200 9 100 1450 1550 Delantero izquierdo 5 000 4 000 650 850 Posterior izquierdo 10 500 9 100 1450 1550 Encendido del quemador y reencendido autom tico Este electrodom stico est e...

Страница 23: ...USAGE INCORRECT PEUVENT ENTRA NER DES BLESSURES OU DES D G TS GRAVES L INTENTION DE L INSTALLATEUR VEUILLEZ LAISSER CES INSTRUCTIONS AVEC L APPAREIL L INTENTION DU CONSOMMATEUR VEUILLEZ CONSERVER CET...

Страница 24: ...us du comptoir doit avoir un support une distance maximum de 3 po 7 6 cm des rebords de la d coupe Pose d armoires au dessus de la plaque de cuisson Jenn Air A 30 po 76 2 cm minimum entre la plaque de...

Страница 25: ...sur la conduite de gaz de cet appareil Quand un raccord flexible de gas est utilis il ne doit pas exc der une longueur de trois 3 pieds 36 pouces 91 4 cm Sauf indication contraire toutes les conduites...

Страница 26: ...e 1 2 po NPT 13 mm Poser un robinet d arr t dans un endroit accessible de la conduite de gaz en amont du d tendeur et ext rieure l appareil afin de pouvoir fermer ou ouvrir l alimentation en gaz de l...

Страница 27: ...n en gaz de l appareil Effectuer toutes connexions de conduite suppl mentaires en amont du robinet d arr t de l alimentation en gaz S assurer que tous les raccords sont bien serr s I M P O R T A N T A...

Страница 28: ...es apparaissent autour des joints et des raccords il y a une fuite En cas de fuite fermer le robinet d alimentation de gaz serrer les raccords ouvrir le robinet de gaz et rev rifier s il y a des fuite...

Страница 29: ...i re de la tablette Si la prise doit tre mont e dans une armoire adjacente gauche ou droite un trou comme celui d crit ci dessus doit tre pratiqu dans la cloison entre les armoires La figure 4 page 5...

Страница 30: ...retiennent en place Voir la figure 7 tape 3 Pousser fermement un tourne crou de 9 32 po ou 7 mm sur les raccords orifice figure 7 et desserrer le raccord en le tournant dans le sens anti horaire Reti...

Страница 31: ...ER DES DOIGTS SUR LES BORDS DU DISQUE POUR REMETTRE LA BROCHE DANS LE CAPUCHON FAIRE PRESSION SUR LE C T DU BOUT DES DOIGTS POUR ENLEVER LA BROCHE DU CAPUCHON GPL GPL C R GLAGE DE LA FLAMME DE MIJOTAG...

Страница 32: ...lectricit avant de proc der la conversion AVERTISSEMENT Si cet appareil a t converti au GPL chacune des modifications suivantes doit tre effectu e pour le reconvertir au gaz naturel A REMPLACER TOUS...

Страница 33: ...eu doux Avant droit 15 000 15 000 2 000 2 000 Arri re droit 9 200 9 100 1 450 1 550 Avant gauche 5 000 4 000 650 850 Arri re gauche 10 500 9 100 1 450 1 550 Allumage standard et allumage automatique d...

Отзывы: