Installation Clearances

IMPORTANT:

 If installing a range hood or microwave hood 

combination above the range, follow the range hood or 

microwave hood combination installation instructions for 

dimensional clearances above the cooktop surface.

A.  18" (45.7 cm) minimum clearance upper cabinet to countertop
B. Cabinet
C.  36" (91.4 cm)
D.  13" (33 cm) maximum recommended upper cabinet depth
E.  6" (15.2 cm) minimum side wall clearance
F.  30" (76.2 cm) minimum clearance between top of cooktop 

platform and bottom of uncovered wood or metal cabinet 

(24" [61 cm] minimum clearance if bottom of wood or metal 

cabinet is covered by not less than ¹⁄

4

" [0.6 cm] flame retardant 

millboard covered with not less than No. 28 MSG sheet steel, 

0.015" [0.04 cm] stainless steel, or 0.024" [0.06 cm] aluminum 

or 0.020" [0.05 cm] copper)

G. 2

5

16

" (5.9 cm) minimum distance to rear combustible surface

H. 2

5

16

" (5.9 cm) minimum distance to front countertop edge

I.  Cutout width - 29³⁄

8

" (74.6 cm) on 30" (76.2 cm) models 

Cutout width - 35³⁄

8

" (89.9 cm) on 36" (91.4 cm) models

J.  Cutout depth - 20³⁄

8

" (51.8 cm)

NOTE:

 After making the countertop cutout, some installations 

may require notching down the base cabinet side walls to clear 

the burner box. To avoid this modification, use a base cabinet 

with sidewalls wider than the cutout.
If cabinet has a drawer, a 4" (10.2 cm) depth clearance from the 

countertop to the top of the drawer (or other obstruction) in base 

cabinet is required. The drawer depth may need to be shortened 

to avoid interfering with the regulator and power cord.

Electrical Requirements

IMPORTANT:

 The cooktop must be electrically grounded in 

accordance with local codes and ordinances, or in the absence 

of local codes, with the National Electrical Code, ANSI/NFPA 70 

or Canadian Electrical Code, CSA C22.1.
This cooktop is equipped with an electronic ignition system 

that will not operate if plugged into an outlet that is not properly 

polarized.
This cooktop is equipped with an electronic ignition system that 

will not operate properly if plugged into a ground fault interrupt 

circuit.
If codes permit and a separate ground wire is used, it is 

recommended that a qualified electrical installer determine 

that the ground path is adequate.
A copy of the above code standards can be obtained from:

National Fire Protection Association 

1 Batterymarch Park 

Quincy, MA 02169-7471

CSA International 

8501 East Pleasant Valley Road 

Cleveland, OH 44131-5575

 

A 120-volt, 60 Hz., AC only, 15-amp fused, electrical circuit 

is required. A time-delay fuse or circuit breaker is also 

recommended. It is recommended that a separate circuit 

serving only this range be provided.

 

Electronic ignition systems operate within wide voltage limits, 

but proper grounding and polarity are necessary. Check that 

the outlet provides 120-volt power and is correctly grounded 

and polarized.

 

The wiring diagram is provided with this cooktop. See 

“Wiring Diagram” section.

B

A

D

E

C

F

G

H

I

J

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, 
fire, or electrical shock.

WARNING

Содержание JGC2536EB

Страница 1: ... DE CÂBLAGE 18 COOKTOP SAFETY You can be killed or seriously injured if you don t immediately You can be killed or seriously injured if you don t follow All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed Your safety and the safety of others are very important We have provided m...

Страница 2: ...nward toward this gas cooking appliance This type of ventilation system may cause ignition and combustion problems with this gas cooking appliance resulting in personal injury or unintended operation WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors...

Страница 3: ... in the wall or floor where cooktop is to be installed must be sealed Cabinet opening dimensions that are shown must be used Given dimensions are minimum clearances Grounded electrical supply is required See Electrical Requirements section Proper gas supply connection must be available See Gas Supply Requirements section The gas and electric supply should be located as shown in Gas and Electric Co...

Страница 4: ...fering with the regulator and power cord Electrical Requirements IMPORTANT The cooktop must be electrically grounded in accordance with local codes and ordinances or in the absence of local codes with the National Electrical Code ANSI NFPA 70 or Canadian Electrical Code CSA C22 1 This cooktop is equipped with an electronic ignition system that will not operate if plugged into an outlet that is not...

Страница 5: ...ls used in the system Flexible metal appliance connector If local codes permit use a 5 8 flexible stainless steel tubing gas connector designed by CSA to connect the cooktop to the rigid gas supply line A 1 3 cm male pipe thread is needed for connection to the female pipe threads of the inlet to the appliance pressure regulator Do not kink or damage the flexible metal tubing when moving the cookto...

Страница 6: ...ee the Make Gas Connection section 1 Optional Remove the foam strip from the hardware package Remove the backing from the foam strip Apply the foam strip with the adhesive side to the countertop on of the edge of the cutout front back and sides NOTE The foam strip helps keep the underside of the cooktop frame free from debris and helps the cooktop sit flat on uneven countertops A Countertop B Foam...

Страница 7: ... You will need to determine the fittings required depending on your installation Typical flexible connection 1 Apply pipe joint compound made for use with LP gas to the larger thread ends of the flexible connector adapters see D and F in the following illustration 2 Attach 1 adapter to the gas pressure regulator and the other adapter to the gas shutoff valve Tighten both adapters 3 Use a 15 16 com...

Страница 8: ...ue color It should be clean and soft in character No yellow tip blowing or lifting of flame should occur Occasional orange flashes are normal and reflect different elements in the air or gas 3 Repeat for the LO position 4 Repeat for the SIM position 5 After verifying the proper burner operation turn the control knobs to OFF If burners do not light properly Turn the surface burner control knob to t...

Страница 9: ...is pushed in and rotated from 0 to 210 counterclockwise from OFF 120 VAC 60 Hz 1 Phase 15 Amp GND Power Cord Plug L1 GND N GN BK BK WH WH 1 WH 2 WH 3 WH 4 WH 5 Spark Modules BK Valve Switches RF L1 N N L1 RR BK BK BK C N L1 RR RF C LR LF LR N L1 BK BK BK BK BK BK RF C LF LR LF N L1 Electrodes RR ...

Страница 10: ...t AVERTISSEMENT L odorat ne permet pas toujours la détection d une fuite de gaz Les distributeurs de gaz recommandent l emploi d un détecteur de gaz homologation UL ou CSA Pour d autre information contacter le fournisseur de gaz local En cas de détection d une fuite de gaz exécuter les instructions Que faire dans le cas d une odeur de gaz AVERTISSEMENT Si les renseignements dans ce manuel ne sont ...

Страница 11: ...alement La table de cuisson doit être installée dans un emplacement à l écart des zones de forts courants d air telles que fenêtres portes et évents ou ventilateurs de chauffage Toutes les ouvertures dans le mur ou le plancher de l emplacement d installation de la table de cuisson doivent être scellées Respecter les dimensions indiquées pour les ouvertures à découper dans les meubles Ces dimension...

Страница 12: ...et le plan de travail B Placard C 36 91 4 cm D Profondeur maximale recommandée pour le placard supérieur 13 33 cm E Dégagement minimal de la paroi latérale de 6 15 2 cm F Distance minimale de séparation de 30 76 2 cm entre le dessus de la table de cuisson et le fond d un placard métallique ou de bois non couvert distance de séparation de 24 61 cm ou plus si le fond du placard de métal ou de bois e...

Страница 13: ...lements locaux En l absence de code local l installation doit satisfaire aux prescriptions de la plus récente édition du code national en vigueur National Fuel Gas Code ANSI Z223 1 ou CAN CGA B149 IMPORTANT Les tests de fuite de la table de cuisson doivent être effectués selon les instructions du fabricant Type de gaz Gaz naturel Cette table de cuisson a été configurée à l usine pour l alimentatio...

Страница 14: ...son TEFLON est une marque déposée de E I Du Pont De Nemours et Compagnie Détendeur Le détendeur fourni avec cette table de cuisson doit être utilisé La pression d alimentation du détendeur doit être comme suit pour un fonctionnement correct Gaz naturel Pression minimum 6 15 2 cm colonne d eau Pression maximum 14 35 5 cm colonne d eau Gaz propane Pression minimum 11 27 9 cm colonne d eau Pression m...

Страница 15: ...e brides de fixation 1 Installer la table de cuisson dans l ouverture du plan de travail en inclinant une extrémité de la table de cuisson dans l ouverture puis en abaissant l autre extrémité dans l ouverture REMARQUE S assurer que le bord avant de la table de cuisson est parallèle au bord avant du plan de travail S il est nécessaire de repositionner la table de cuisson la soulever entièrement de ...

Страница 16: ... 1 Appliquer un composé d étanchéité des filetages résistant au propane sur l extrémité filetée la plus grosse des adaptateurs de raccord flexible voir D et F sur l illustration suivante 2 Fixer un raccord d adaptation sur le régulateur de pression du gaz et l autre raccord d adaptation sur le robinet d arrêt de la canalisation de gaz Serrer les deux adaptateurs 3 Utiliser une clé mixte de 15 16 e...

Страница 17: ...ystème d allumage électronique Contrôle du fonctionnement des brûleurs de surface 1 Enfoncer et tourner les boutons de commande de brûleur de surface à la position HI élevé Le gaz doit s enflammer sur le brûleur de surface en moins de 4 secondes Lors de l allumage initial du brûleur de surface le délai d allumage peut être supérieur à 4 secondes du fait de la présence d air dans la canalisation de...

Страница 18: ...dans le sens anti horaire entre 0 et 210 depuis la position d arrêt Terre Ph1 Terre NEU VE N N BL BL 1 BL 2 BL 3 BL 4 BL 5 N AvD Ph1 Neu Neu ArD N N N C Neu Ph1 C ArG Neu Ph1 N N N N N N C AvG Neu Ph1 Électrodes 120 VCA 60 Hz monophasé 15 A Prise du cordon d alimentation Modules d allumage Contacteurs du robinet ArD ArD AvD AvD ArG ArG AvG AvG Ph1 ...

Страница 19: ...19 Notes ...

Страница 20: ...W10821219A 2015 Jenn Air Used under license in Canada All rights reserved Utilisé sous licence au Canada Tous droits réservés 10 15 ...

Отзывы: