background image

3

INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation.

Tools needed

 

Tape measure

 

Flat-blade screwdriver

 

15

16

" (24 mm) combination  

wrench

 

Pipe wrench

 

Channel lock pliers

Parts supplied

 

Gas pressure regulator

 

Burner grates: common (4), center (1)

 

Burner bases (5)

 

Burner caps (5)

 

Simmer cap

 

Clamp brackets (2)

 

2¹⁄

2

" (6.4 cm) clamping screws (2)

 

Foam tape seal

 

LP conversion kit - W10686634

Parts needed

Check local codes and consult gas supplier. Check existing gas 

supply and electrical supply. See “Electrical Requirements” and 

“Gas Supply Requirements” sections.

Location Requirements

IMPORTANT:

 Observe all governing codes and ordinances. Do 

not obstruct flow of combustion and ventilation air.

 

It is the installer’s responsibility to comply with installation 

clearances specified on the model/serial/rating plate. The 

model/serial/rating plate is located on the underside of the 

cooktop burner box.

 

Do not unpack the burner grates and bases until after the 

cooktop is installed to avoid scratching the cooktop.

 

To eliminate the risk of burns or fire by reaching over heated 

surface units, cabinet storage space located above the 

surface units should be avoided. If cabinet storage is to be 

provided, the risk can be reduced by installing a range hood 

that projects horizontally a minimum of 5" (12.7 cm) beyond 

the bottom of the cabinets.

 

The cooktop should be installed in a location away from 

strong draft areas, such as windows, doors and strong 

heating vents or fans.

 

All openings in the wall or floor where cooktop is to be 

installed must be sealed.

 

Cabinet opening dimensions that are shown must be used. 

Given dimensions are minimum clearances.

 

Grounded electrical supply is required. See “Electrical 

Requirements” section.

 

Proper gas supply connection must be available. See “Gas 

Supply Requirements” section.

 

The gas and electric supply should be located as shown in 

“Gas and Electric Connection Locations” in the “Location 

Requirements” section so that they are accessible without 

requiring removal of the cooktop.

 

Marker or pencil

 

Pipe-joint compound 

resistant to LP gas

 

Noncorrosive leak-detection 

solution

IMPORTANT: 

To avoid damage to your cabinets, check with 

your builder or cabinet supplier to make sure that the materials 

used will not discolor, delaminate or sustain other damage.

Mobile Home - Additional Installation Requirements

The installation of this cooktop must conform to the 

Manufactured Home Construction and Safety Standard, Title 24 

CFR, Part 3280 (formerly the Federal Standard for Mobile Home 

Construction and Safety, Title 24, HUD Part 280). When such 

standard is not applicable, use the Standard for Manufactured 

Home Installations, ANSI A225.1/NFPA 501A or with local codes.
In Canada, the installation of this cooktop must conform with the 

current standards CAN/CSA-A240-latest edition, or with local 

codes.

Product Dimensions

A.  *21" (53.3 cm)
B.  *30" (76.2 cm) on 30" (76.2 cm) models 

36" (91.4 cm) on 36" (91.4 cm) models

C. 3

1

/

4

" (8.3 cm)

*Metal tabs should not be bent during installation

Gas and Electric Connection Locations

A.  Gas pressure regulator (supplied) - arrow pointed 

toward cooktop

B.  3 prong grounding type outlet with correct polarity
C.  Gas shutoff valve
D.  18" (45.7 cm) minimum

A

B

C

C

A

B

D

Содержание JGC2536EB

Страница 1: ... DE CÂBLAGE 18 COOKTOP SAFETY You can be killed or seriously injured if you don t immediately You can be killed or seriously injured if you don t follow All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed Your safety and the safety of others are very important We have provided m...

Страница 2: ...nward toward this gas cooking appliance This type of ventilation system may cause ignition and combustion problems with this gas cooking appliance resulting in personal injury or unintended operation WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors...

Страница 3: ... in the wall or floor where cooktop is to be installed must be sealed Cabinet opening dimensions that are shown must be used Given dimensions are minimum clearances Grounded electrical supply is required See Electrical Requirements section Proper gas supply connection must be available See Gas Supply Requirements section The gas and electric supply should be located as shown in Gas and Electric Co...

Страница 4: ...fering with the regulator and power cord Electrical Requirements IMPORTANT The cooktop must be electrically grounded in accordance with local codes and ordinances or in the absence of local codes with the National Electrical Code ANSI NFPA 70 or Canadian Electrical Code CSA C22 1 This cooktop is equipped with an electronic ignition system that will not operate if plugged into an outlet that is not...

Страница 5: ...ls used in the system Flexible metal appliance connector If local codes permit use a 5 8 flexible stainless steel tubing gas connector designed by CSA to connect the cooktop to the rigid gas supply line A 1 3 cm male pipe thread is needed for connection to the female pipe threads of the inlet to the appliance pressure regulator Do not kink or damage the flexible metal tubing when moving the cookto...

Страница 6: ...ee the Make Gas Connection section 1 Optional Remove the foam strip from the hardware package Remove the backing from the foam strip Apply the foam strip with the adhesive side to the countertop on of the edge of the cutout front back and sides NOTE The foam strip helps keep the underside of the cooktop frame free from debris and helps the cooktop sit flat on uneven countertops A Countertop B Foam...

Страница 7: ... You will need to determine the fittings required depending on your installation Typical flexible connection 1 Apply pipe joint compound made for use with LP gas to the larger thread ends of the flexible connector adapters see D and F in the following illustration 2 Attach 1 adapter to the gas pressure regulator and the other adapter to the gas shutoff valve Tighten both adapters 3 Use a 15 16 com...

Страница 8: ...ue color It should be clean and soft in character No yellow tip blowing or lifting of flame should occur Occasional orange flashes are normal and reflect different elements in the air or gas 3 Repeat for the LO position 4 Repeat for the SIM position 5 After verifying the proper burner operation turn the control knobs to OFF If burners do not light properly Turn the surface burner control knob to t...

Страница 9: ...is pushed in and rotated from 0 to 210 counterclockwise from OFF 120 VAC 60 Hz 1 Phase 15 Amp GND Power Cord Plug L1 GND N GN BK BK WH WH 1 WH 2 WH 3 WH 4 WH 5 Spark Modules BK Valve Switches RF L1 N N L1 RR BK BK BK C N L1 RR RF C LR LF LR N L1 BK BK BK BK BK BK RF C LF LR LF N L1 Electrodes RR ...

Страница 10: ...t AVERTISSEMENT L odorat ne permet pas toujours la détection d une fuite de gaz Les distributeurs de gaz recommandent l emploi d un détecteur de gaz homologation UL ou CSA Pour d autre information contacter le fournisseur de gaz local En cas de détection d une fuite de gaz exécuter les instructions Que faire dans le cas d une odeur de gaz AVERTISSEMENT Si les renseignements dans ce manuel ne sont ...

Страница 11: ...alement La table de cuisson doit être installée dans un emplacement à l écart des zones de forts courants d air telles que fenêtres portes et évents ou ventilateurs de chauffage Toutes les ouvertures dans le mur ou le plancher de l emplacement d installation de la table de cuisson doivent être scellées Respecter les dimensions indiquées pour les ouvertures à découper dans les meubles Ces dimension...

Страница 12: ...et le plan de travail B Placard C 36 91 4 cm D Profondeur maximale recommandée pour le placard supérieur 13 33 cm E Dégagement minimal de la paroi latérale de 6 15 2 cm F Distance minimale de séparation de 30 76 2 cm entre le dessus de la table de cuisson et le fond d un placard métallique ou de bois non couvert distance de séparation de 24 61 cm ou plus si le fond du placard de métal ou de bois e...

Страница 13: ...lements locaux En l absence de code local l installation doit satisfaire aux prescriptions de la plus récente édition du code national en vigueur National Fuel Gas Code ANSI Z223 1 ou CAN CGA B149 IMPORTANT Les tests de fuite de la table de cuisson doivent être effectués selon les instructions du fabricant Type de gaz Gaz naturel Cette table de cuisson a été configurée à l usine pour l alimentatio...

Страница 14: ...son TEFLON est une marque déposée de E I Du Pont De Nemours et Compagnie Détendeur Le détendeur fourni avec cette table de cuisson doit être utilisé La pression d alimentation du détendeur doit être comme suit pour un fonctionnement correct Gaz naturel Pression minimum 6 15 2 cm colonne d eau Pression maximum 14 35 5 cm colonne d eau Gaz propane Pression minimum 11 27 9 cm colonne d eau Pression m...

Страница 15: ...e brides de fixation 1 Installer la table de cuisson dans l ouverture du plan de travail en inclinant une extrémité de la table de cuisson dans l ouverture puis en abaissant l autre extrémité dans l ouverture REMARQUE S assurer que le bord avant de la table de cuisson est parallèle au bord avant du plan de travail S il est nécessaire de repositionner la table de cuisson la soulever entièrement de ...

Страница 16: ... 1 Appliquer un composé d étanchéité des filetages résistant au propane sur l extrémité filetée la plus grosse des adaptateurs de raccord flexible voir D et F sur l illustration suivante 2 Fixer un raccord d adaptation sur le régulateur de pression du gaz et l autre raccord d adaptation sur le robinet d arrêt de la canalisation de gaz Serrer les deux adaptateurs 3 Utiliser une clé mixte de 15 16 e...

Страница 17: ...ystème d allumage électronique Contrôle du fonctionnement des brûleurs de surface 1 Enfoncer et tourner les boutons de commande de brûleur de surface à la position HI élevé Le gaz doit s enflammer sur le brûleur de surface en moins de 4 secondes Lors de l allumage initial du brûleur de surface le délai d allumage peut être supérieur à 4 secondes du fait de la présence d air dans la canalisation de...

Страница 18: ...dans le sens anti horaire entre 0 et 210 depuis la position d arrêt Terre Ph1 Terre NEU VE N N BL BL 1 BL 2 BL 3 BL 4 BL 5 N AvD Ph1 Neu Neu ArD N N N C Neu Ph1 C ArG Neu Ph1 N N N N N N C AvG Neu Ph1 Électrodes 120 VCA 60 Hz monophasé 15 A Prise du cordon d alimentation Modules d allumage Contacteurs du robinet ArD ArD AvD AvD ArG ArG AvG AvG Ph1 ...

Страница 19: ...19 Notes ...

Страница 20: ...W10821219A 2015 Jenn Air Used under license in Canada All rights reserved Utilisé sous licence au Canada Tous droits réservés 10 15 ...

Отзывы: