background image

Oven Control Testing Procedures 

 

!

WARNING

 

To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless  
testing requires power. 

 

February 2005 

16025924 

©2005 Maytag Services 

Relay Logic 

NOTE: 

Subsequent changes implemented after the release of this technical sheet may have altered the parameters 
identified in this chart. 

COOKING MODE 

BAKE 

BR

O

IL 

CONV

E

C

T FA

N HI S

P

E

E

D

 

CONV

E

C

T FA

N LO S

P

E

E

O

VEN

 LIG

H

T

 

IDLE 

r

 

r

 

r

 

r

 

 

BAKE PREHEAT 

 

 

r

 

r

 

 

BAKE 

 

 

r

 

r

 

 

HIGH BROIL PREHEAT 

r

 

r

 

r

 

 

HIGH BROIL 

r

 

r

 

r

 

 

LOW BROIL PREHEAT 

r

 

 

r

 

r

 

 

LOW BROIL 

r

 

 

r

 

r

 

 

CLEAN PREHEAT 

r

 

r

 

r

 

r

 

CLEAN 

r

 

r

 

r

 

r

 

KEEP WARM PREHEAT 

 

r

 

r

 

r

 

 

KEEP WARM 

 

r

 

r

 

r

 

 

CONVECT ROAST PREHEAT 

 

 

O

*

 

r

 

 

CONVECT ROAST 

 

 

O

*

 

r

 

 

CONVECT BAKE QUICK PREHEAT 

 

 

r

 

O

*

 

 

CONVECT BAKE PREHEAT 

 

 

r

 

O

*

 

 

CONVECT BAKE 

 

 

r

 

O

*

 

 

QUICK PROOFING PREHEAT 

 

 

r

 

O

*

 

 

QUICK PROOFING 

 

 

r

 

O

*

 

 

STANDARD PROOFING PREHEAT 

 

 

r

 

r

 

 

STANDARD PROOFING 

 

 

r

 

r

 

 

DRYING PREHEAT 

 

 

O

*

 

r

 

 

DRYING 

 

 

O

*

 

r

 

 

*

Convection fan stops when oven door is opened.

 

 

 

 
 
 
 
 

INDEX 

 -  OFF 

O  -  ON 

 -  CYCLING 

 -  ON OR OFF (DETERMINED BY USER INPUT) 

Содержание JES9750AA Series

Страница 1: ...1 200 2 ea 1 200 Ribbon 1 800 N A 1 800 Ribbon N A 2 200 2 ea N A Grill assembly 1 900 N A 1 900 Oven Wattage 240 V 208 V Bake 2 500 1 900 2 500 1 900 2 500 1 900 Broil 4 000 3 000 4 000 3 000 4 000 3 000 Oven Interior Dimensions in cm Height 16 1 2 41 9 16 1 2 41 9 16 1 2 41 9 Width 23 58 4 23 58 4 23 58 4 Depth 18 1 8 46 18 1 8 46 18 1 8 46 Product Exterior Dimensions in cm Height Overall 35 3 4...

Страница 2: ...ommon is in neutral position unless locking or unlocking autolatch assembly Halogen element 1200 W 6 5 in 165 mm Models JES9750AA JES9860AA Disconnect wiring to element and measure cold resistance of terminals Measure voltage at element Approx 48 Ω 240 VAC Halogen element 1200 W 8 in 200 mm Models JES9750AA JES9860AA Disconnect wiring to element and measure cold resistance of terminals Measure vol...

Страница 3: ...nite Continuity Convection assembly Convection motor Models JES9800AA JES9860AA Measure voltage Check motor windings to ground 120 VAC tolerance 105 to 135 VAC No continuity RPM Approx 1750 to 2250 Cooling fan motor Measure voltage Check motor windings to ground 120 VAC No continuity RPM Idle 3395 Load 3000 Breakdown 2400 Downdraft motor Check motor windings to ground No continuity RPM 1550 2 4 am...

Страница 4: ...rature Display Press Setup Options and the Temp C F pad also the 7 pad simultaneously Press Autoset to select option F or C EOC II Language Display Press Setup Options and the Language pad also the 8 pad simultaneously Press Autoset to select option English French or Spanish EOC II Factory Default Press Setup Options and the Default pad also the 9 pad simultaneously Press Autoset to reset clock to...

Страница 5: ...FAN HI SPEED CONVECT FAN LO SPEED OVEN LIGHT IDLE r r r r BAKE PREHEAT r r BAKE r r HIGH BROIL PREHEAT r O r r HIGH BROIL r O r r LOW BROIL PREHEAT r r r LOW BROIL r r r CLEAN PREHEAT r O r r r CLEAN O r r r r KEEP WARM PREHEAT r r r KEEP WARM r r r CONVECT ROAST PREHEAT O r CONVECT ROAST O r CONVECT BAKE QUICK PREHEAT r O CONVECT BAKE PREHEAT r O CONVECT BAKE r O QUICK PROOFING PREHEAT r O QUICK ...

Страница 6: ...vated 1 displayed in control display window CONVECT BAKE Convection Bake relay activated Convection Fan cycles 1 displayed in control display window CONVECT ROAST Convection Roast relay activated Convection Fan cycles 1 displayed in control display window OVEN LIGHT Oven light relay activated 1 displayed in control display window PROBE Actual Probe temperature and 1 displayed in control display wi...

Страница 7: ... control F1 8 Shorted key pad in membrane switch Ensure ribbon cable is securely connected inspect ribbon cable and connector shorts breakage corrosion etc If OK replace control F1 9 Internal control communication errors Replace control F1 A Lock unlock switch state not advancing to control Check connections harness and motor If OK replace control F1 C Oven door switch state not advancing to contr...

Страница 8: ... Schematic WARNING To avoid risk of electrical shock personal injury or death disconnect power to oven before servicing unless testing requires power 16025924 8 February 2005 2005 Maytag Services JES9750AA Wiring Diagram ...

Страница 9: ...Schematic WARNING To avoid risk of electrical shock personal injury or death disconnect power to oven before servicing unless testing requires power February 2005 9 16025924 2005 Maytag Services JES9750AA Control Circuits ...

Страница 10: ...Schematic WARNING To avoid risk of electrical shock personal injury or death disconnect power to oven before servicing unless testing requires power 16025924 10 February 2005 2005 Maytag Services JES9800AA Wiring Diagram ...

Страница 11: ...chematic WARNING To avoid risk of electrical shock personal injury or death disconnect power to oven before servicing unless testing requires power February 2005 11 16025924 2005 Maytag Services JES9800AA Control Circuits ...

Страница 12: ...Schematic WARNING To avoid risk of electrical shock personal injury or death disconnect power to oven before servicing unless testing requires power 16025924 12 February 2005 2005 Maytag Services JES9860AA Wiring Diagram ...

Страница 13: ...chematic WARNING To avoid risk of electrical shock personal injury or death disconnect power to oven before servicing unless testing requires power February 2005 13 16025924 2005 Maytag Services JES9860AA Control Circuits ...

Отзывы: