Jenn-Air 48

12

GAS CONVERSIONS

IMPORTANT: Gas conversions from Natural gas to LP gas must 
be done by a qualified installer.

LP Gas Conversion

1. Turn the manual shutoff valve to the closed position.

2. Unplug cooktop or disconnect power.

To Convert Gas Pressure Regulator

1. Remove the access cap by using a wrench, turning the 

access cap counterclockwise.

2. Remove spring retainer from the cap by pushing against the 

flat side of the spring retainer. Look at the spring retainer to 
locate the “NAT” or “LP” position. Turn over the spring 
retainer so the “LP” is showing on the bottom. Snap the 
spring retainer back into the cap. Reinstall the cap onto the 
regulator.

3. Test the gas pressure regulator and gas supply line.

The regulator must be checked at a minimum 1" (2.5 cm) 
water column above the set pressure. The inlet pressure to 
the regulator should be as follows for operation and checking 
the regulator setting:

LP Gas:
Minimum pressure 11" (27.9 cm) WCP 
Maximum pressure 14" (35.5 cm) WCP

Gas Supply Pressure Testing

Gas supply pressure for testing regulator must be at least 
1" water column pressure above the manifold pressure 
shown on the model/serial rating plate.

Line pressure testing above ½ psi gauge (14" WCP)

The cooktop and its individual shutoff valve must be 
disconnected from the gas supply piping system during any 
pressure testing of that system at test pressures in excess of 
½ psi (3.5 kPa).

Line pressure testing at ½ psi gauge (14" WCP) or lower

The cooktop must be isolated from the gas supply piping 
system by closing its individual manual shutoff valve during 
any pressure testing of the gas supply piping system at test 
pressures equal to or less than ½ psi (3.5 kPa).

A. To cooktop
B. Shutoff valve (closed position)

C. Gas supply line

WARNING

Explosion Hazard

Use a new CSA International approved gas supply line.

Install a shut-off valve.

Securely tighten all gas connections.

If connected to LP, have a qualified person make sure 
gas pressure does not exceed 14" (36 cm) water 
column. 

Examples of a qualified person include: 

licensed heating personnel, 
authorized gas company personnel, and
authorized service personnel.

Failure to do so can result in death, explosion, or fire.

A

B

C

A. Access cap
B. Gasket

C. Gas pressure regulator

D. LP position

E. NAT position

A

B

C

D

E

Содержание 48" (121.9 CM)

Страница 1: ...IGENCES D INSTALLATION 16 Outillage et pi ces 16 Exigences d emplacement 16 Exigences concernant l vacuation 18 M thodes d vacuation 18 Sp cifications lectriques 20 Sp cifications de l alimentation en...

Страница 2: ...property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to li...

Страница 3: ...uired See Electrical Requirements section Proper gas supply connection must be available See Gas Supply Requirements section The cooktop is designed to hang from the countertop by its side or rear fla...

Страница 4: ...material Metal duct may be reduced to 30 gauge galvanized steel or 26 gauge aluminized steel if allowed by local codes This reduction is based on information in the International Residential Codes Se...

Страница 5: ...keup Air Local building codes may require the use of makeup air systems when using ventilation systems greater than specified CFM of air movement The specified CFM varies from locale to locale Consult...

Страница 6: ...this cooktop See Wiring Diagrams on a separate sheet The wiring diagrams are located on the left underside of the cooktop base GasSupplyRequirements Observe all governing codes and ordinances IMPORTA...

Страница 7: ...the cooktop connection All strains must be removed from the supply and fuel lines so cooktop will be level and in line Must include a shutoff valve The supply line must be equipped with a manual shut...

Страница 8: ...re people remove the cooktop from the carton REMEMBER An undercounter built in oven cannot be installed under this cooktop 7 Place cooktop right side up into the cutout NOTE Make sure that the front e...

Страница 9: ...k detection solution If bubbles appear a leak is indicated Correct any leak found 3 Remove surface burner caps and grates from parts package Align notches in burner caps with pins in burner base Burne...

Страница 10: ...Light 1 burner and turn to lowest setting 2 Remove the control knob 3 Hold the knob stem in the low position using a pair of pliers Use an 3 0 mm flat blade screwdriver to turn the screw located in th...

Страница 11: ...nd warm water to clean cooktop before use Dry thoroughly with a soft cloth For more information see the Cooktop Care section of the Use and Care Guide 5 Read Cooktop Use in the cooktop Use and Care Gu...

Страница 12: ...ng regulator must be at least 1 water column pressure above the manifold pressure shown on the model serial rating plate Line pressure testing above psi gauge 14 WCP The cooktop and its individual shu...

Страница 13: ...flat side of the spring retainer Look at the spring retainer to locate the LP or NAT position Turn over the spring retainer so the NAT is showing on the bottom Snap the spring retainer back into the...

Страница 14: ...ing burners Complete Installation 1 Refer to the Make Gas Connection section for properly connecting the cooktop to the gas supply 2 Refer to the Burner Ignition section for proper burner ignition ope...

Страница 15: ...u un d c s Ne pas entreposer ni utiliser de l essence ou d autres vapeurs ou liquides inflammables proximit de cet appareil ou de tout autre appareil lectrom nager QUE FAIRE DANS LE CAS D UNE ODEUR DE...

Страница 16: ...de forts courants d air telles que fen tres portes et vents ou ventilateurs de chauffage Toutes les ouvertures dans le mur ou le plancher de l emplacement d installation de la table de cuisson doiven...

Страница 17: ...Axe du d tendeur de l appareil C 46 118 9 cm D 3 8 4 cm jusqu au fond de la bo te de br leurs E 1 9 cm F Extr mit de la bo te de br leurs G 28 72 9 cm H 14 35 6 cm I D gagement de 2 5 1 cm min entre...

Страница 18: ...ulation de l air Ne pas utiliser de coude de 5 12 7 cm dans un circuit de 6 15 2 cm ou 3 x 10 8 3 x 25 4 cm Ne pas effectuer de r duction vers un circuit de 5 12 7 cm apr s avoir utilis des raccords d...

Страница 19: ...que de dia 6 15 2 cm F Raccord PVC de dia 6 15 2 cm G Dalle de b ton H Conduit PVC pour gout de dia 6 15 2 cm I Coude 90 en PVC pour gout de dia 6 15 2 cm J Gravier ou sable compact tout autour du tuy...

Страница 20: ...codes et r glements locaux En l absence de code local l installation doit satisfaire aux prescriptions de la plus r cente dition du code national am ricain en vigueur National Fuel Gas Code ANSI Z223...

Страница 21: ...e n cessite pas le d montage de la table de cuisson pour les man uvres d ouverture fermeture Ne pas entraver l acc s au robinet d arr t manuel Le robinet d arr t manuel est pr vu pour ouvrir ou fermer...

Страница 22: ...as possible d installer un four encastr sous cette table de cuisson 7 Placer la table de cuisson dans l ouverture c t droit vers le haut REMARQUE S assurer que le bord avant de la table de cuisson est...

Страница 23: ...ch it des tuyauteries con u pour l utilisation avec le gaz naturel ou le propane Ne pas utiliser de ruban TEFLON Il sera n cessaire de choisir les raccords utiliser en fonction de la configuration d i...

Страница 24: ...soufflage ou de s paration entre les flammes et le br leur Il est normal d observer parfois des clairs oranges ceci est d diff rents l ments dans l air ou le gaz Apr s avoir v rifi le bon fonctionneme...

Страница 25: ...me haute L emmanchement serr de la virole d admission d air garantit qu elle restera en place Sur un br leur la fermeture de l admission d air fera trembler la flamme dont l extr mit deviendra jaune L...

Страница 26: ...Essai de pression de circuit au dessus de lb po 14 de colonne d eau Pour tout essai de pression du circuit une pression sup rieure lb po 3 5 kPa la table de cuisson et son robinet d arriv e doivent t...

Страница 27: ...r 1 Utiliser une cl pour enlever le chapeau de l ouverture d acc s faire tourner le chapeau dans le sens antihoraire 2 ter le ressort de retenue qui se trouve sous le chapeau en poussant contre le c t...

Страница 28: ...es pi ces et conserver le tout avec le sachet de documentation pour pouvoir le r utiliser ult rieurement 5 R p ter ces op rations pour les autres br leurs Achever l installation 1 Consulter la section...