INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation. 
Read and follow the instructions provided with any tools listed here.

Tools needed

Level

Drill with 1¼" (3.0 cm), 

³⁄₈

" (9.5 mm), 

⁷⁄₆₄

" (2.75 mm) and 

¹⁄₈

(3.0 mm) drill bits

Pilot hole drill bits (determined by chimney support 
attachment method)

Pencil

Wire stripper or utility knife

Tape measure or ruler

Pliers

Caulking gun and weatherproof caulking compound

Vent clamps

Jigsaw or keyhole saw

Flat-blade screwdriver

Metal snips

Phillips screwdriver

Parts needed

Home power supply cable

2 - ½" (12.7 mm) UL listed or CSA approved strain reliefs

3 UL listed wire connectors

For vented installations, you will also need: 

1 wall or roof cap

Metal vent system

For non-vented (recirculating) installations, you will also need:

Charcoal Filter Kit Part Number W10272068 for non-vented 
(recirculating) installations only. See “Assistance or Service” 
section to order.

Recirculating Kit Part Number W10272061 for non-vented 
(recirculating) installations only. See “Assistance or Service” 
section to order.

8" (20.3 cm) round metal vent duct. Length required is 
determined by ceiling height. 

Parts Supplied

Remove parts from packages. Check that all parts are included.

Hood canopy assembly with ventilator and light bulbs installed

Filter—installed in hood canopy

64 - 4.2 x 8 mm screws

4 - 5 x 45 mm screws

Mounting template

2 - Upper vent covers

2 - Lower vent covers

Vent transition with backdraft damper installed

4 - Plastic vent clips

Upper horizontal support bracket

Horizontal support

8 - Vertical supports

4 - 3.5 x 6.5 mm screws

2 - 2.9 x 3 mm screws

T10 Torx

®†

 adapter

T20

®

 Torx

®

 adapter

Location Requirements

IMPORTANT:

 Observe all governing codes and ordinances.

Have a qualified technician install the range hood. It is the 
installer's responsibility to comply with installation clearances 
specified on the model/serial rating plate. The model/serial rating 
plate is located behind the left filter on the rear wall of the vent 
hood.
Canopy hood location should be away from strong draft areas, 
such as windows, doors and strong heating vents. 
Cabinet opening dimensions that are shown must be used. Given 
dimensions provide minimum clearance.
Grounded electrical outlet is required. See “Electrical 
Requirements” section.
Because of the size and weight of this island hood, the chimney 
support must be securely attached to the ceiling.

For plaster or drywall ceilings, the chimney support must be 
attached to joists. If this is not possible, you must build a 
support structure behind the plaster or drywall. The support 
structure must be able to support 80 lbs (36.6 kg).

This range hood is recommended for use with cooktops with a 
maximum total rating of 60,000 Btus or less.
The range hood is factory set for venting through the roof.
For non-vented (recirculating) Installation see “Non-vented 
(recirculating) Installations” in “Install Range Hood” section. 
Recirculation Kit Part Number W10272061 is available from your 
dealer or an authorized parts distributor. 
All openings in ceiling and wall where range hood will be installed 
must be sealed.

For Mobile Home Installations

The installation of this range hood must conform to the 
Manufactured Home Construction Safety Standards, Title 24 
CFR, Part 328 (formerly the Federal Standard for Mobile Home 
Construction and Safety, Title 24, HUD, Part 280) or when such 
standard is not applicable, the standard for Manufactured Home 
Installation 1982 (Manufactured Home Sites, Communities and 
Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local 
codes.

Product Dimensions

*Vented installations only

**Non-vented (recirculating) installations only

†®TORX and T20 are registered trademarks of Acument Intellectual Properties, LLC.

12

¹⁄₄

"

 

(31.0 cm)

13

³⁄₁₆

"

(33.5 cm)

36" (91.2 cm)

42" (106.4 cm)

*32

¹⁄₂

(82.6 cm)

min.

*46

¹⁄₂

"

 

(118.0 cm)

max.

**32

¹⁄₂

"

 

(82.6 cm)

min.

**52

⁹⁄₁₆

(133.5 cm)

max.

27" (68.6 cm)

Содержание 36inch AND 42inch (91.4 CM AND 106.7 CM) ISLAND CANOPY RANGE...

Страница 1: ...bsite at www jennair com In Canada call 1 800 JENNAIR 1 800 536 6247 or visit our website at www jennair ca Instructions d installation et Guide d utilisation et d entretien Au Canada pour assistance...

Страница 2: ...u ventilateur 28 ENTRETIEN DE LA HOTTE 29 Nettoyage 29 SCH MA DE C BLAGE 30 ASSISTANCE OU SERVICE 31 Au Canada 31 Accessoires 31 GARANTIE 32 RANGE HOOD SAFETY You can be killed or seriously injured if...

Страница 3: ...ardous or explosive materials and vapors CAUTION To reduce risk of fire and to properly exhaust air be sure to duct air outside do not vent exhaust air into spaces within walls or ceilings attics or i...

Страница 4: ...with installation clearances specified on the model serial rating plate The model serial rating plate is located behind the left filter on the rear wall of the vent hood Canopy hood location should b...

Страница 5: ...k draft damper should be installed to minimize backward cold air flow and a thermal break should be installed to minimize conduction of outside temperatures as part of the vent system The damper shoul...

Страница 6: ...sed electrical circuit is required If the house has aluminum wiring follow the procedure below 1 Connect a section of solid copper wire to the pigtail leads 2 Connect the aluminum wiring to the added...

Страница 7: ...to a ceiling support structure capable of holding 80 lbs 36 6 kg Remove the template 4 Drill 4 4 8 mm pilot holes for mounting the upper horizontal support Complete Preparation 1 Determine the require...

Страница 8: ...ighten to secure Connect Vent System 1 Install vent system 2 Push duct over the exhaust outlet Seal all connections with vent clamps 3 Use caulk to seal all openings Non Vented Recirculating Installat...

Страница 9: ...hten strain relief screw 9 Install terminal box cover 10 Check that all light bulbs are secure in their sockets 11 Reconnect power A Knockout B Terminal box C Terminal box cover WARNING Electrical Sho...

Страница 10: ...he frame to the ceiling and secure to the upper horizontal support with 2 3 5 x 6 5 mm screws 4 Place the long end of the plastic clips 2 into the bottom of the front lower duct cover 5 Install the lo...

Страница 11: ...using 2 plastic clips Use one plastic clip on each side 8 Secure the lower duct cover to the range hood canopy using 4 4 2 x 8 mm screws Complete Installation 1 For non vented recirculating installati...

Страница 12: ...and hold the POWER DECREASE and POWER INCREASE buttons at the same time for 5 seconds None will appear in the display for 3 seconds When the charcoal filter has been excluded the charcoal filter alar...

Страница 13: ...detergent solution 3 Reinstall the filter by making sure the spring release handles are toward the front Insert metal grease filter into upper track 4 Pull the spring release handle down 5 Push up on...

Страница 14: ...3 4 5 1 2 3 4 5 6 YL YL YL BU YL YL YL S4 P9 BK BU BR GY YL WH RD Motor Resistance Ohms Blue Red Blue Gray Blue Black Blue White Room Temp 18 14 3 9 8 21 6 Motor Specifications Power Supply Frequency...

Страница 15: ...ance you can write to Jenn Air Appliances with any questions or concerns at Jenn Air Brand Home Appliances Customer eXperience Center 553 Benson Road Benton Harbor MI 49022 2692 Please include a dayti...

Страница 16: ...light bulbs batteries air or water filters preservation solutions etc 5 Conversion of products from natural gas or L P gas 6 Damage from accident misuse abuse fire floods acts of God or use with prod...

Страница 17: ...re appareil m nager Assurez vous de toujours lire tous les messages de s curit et de vous y conformer AVERTISSEMENT DANGER Voici le symbole d alerte de s curit Ce symbole d alerte de s curit vous sign...

Страница 18: ...que d incendie et vacuer ad quatement les gaz veiller acheminer l air aspir par un conduit jusqu l ext rieur ne pas d charger l air aspir dans un espace vide du b timent comme une cavit murale un plaf...

Страница 19: ...es sp cifi es sur la plaque signal tique de l appareil La plaque signal tique de l appareil est situ e derri re le filtre de gauche sur la paroi arri re de la hotte On doit toujours installer la hott...

Страница 20: ...nch it avec un produit de calfeutrage La taille du conduit doit tre uniforme Installations dans une r gion climat froid Dans le circuit d vacuation on devrait installer un clapet anti reflux additionn...

Страница 21: ...l 8501 East Pleasant Valley Road Cleveland OH 44131 5575 L appareil doit tre aliment par un circuit de 120 V CA seulement 60 Hz 15 amp res prot g par fusible Si le domicile poss de un c blage en alumi...

Страница 22: ...des trous doit se faire dans une structure de soutien du plafond capable de soutenir une charge de 80 lb 36 6 kg Retirer le gabarit 4 Percer 4 avant trous de 4 8 mm pour le montage du support horizont...

Страница 23: ...ncer le conduit sur la bouche d vacuation Utiliser des brides de conduit pour assurer l tanch it de toutes les connexions 3 Utiliser un calfeutrant pour assurer l tanch it au niveau de chaque ouvertur...

Страница 24: ...Installer le couvercle du bo tier de connexion 10 V rifier que chaque ampoule est bien ins r e dans sa douille 11 Reconnecter la source de courant lectrique A Opercule arrachable B Bo tier de connexi...

Страница 25: ...vis de 3 5 x 6 5 mm 4 Placer l extr mit longue des chevilles en plastique 2 au bas de la partie inf rieure avant du cache conduit 5 Installer la partie inf rieure du cache conduit avant l auvent de l...

Страница 26: ...une cheville en plastique de chaque c t 8 Fixer la partie inf rieure du cache conduit l auvent de la hotte de cuisini re en utilisant 4 vis de 4 2 x 8 mm Achever l installation 1 Pour les installatio...

Страница 27: ...Snd son appara t sur l affichage pendant 3 secondes Inclusion et exclusion du filtre charbon accessoire de recyclage Lorsque le filtre charbon est utilis mode recyclage appuyer sur les boutons POWER...

Страница 28: ...de la minuterie commence 3 La minuterie peut tre annul e tout moment en appuyant de nouveau sur le bouton de la minuterie REMARQUE Pendant le r glage de la minuterie les boutons Power Decrease et Powe...

Страница 29: ...e haut et rel cher la poign e pour l embo ter 6 R p ter les tapes 1 5 pour l autre filtre Filtres d installation sans d charge l ext rieur recyclage Le filtre charbon n est pas lavable Celui ci devrai...

Страница 30: ...1 2 3 4 5 1 2 3 4 5 6 JA JA JA BU JA JA JA S4 P9 N BU MAR JA BL R R sistance du moteur ohms Bleu Rouge Bleu Gris Bleu Noir Bleu Blanc Temp amb 18 14 3 9 8 21 6 Caract ristiques du moteur Alimentation...

Страница 31: ...techniciens de service d sign s par Jenn Air sont form s pour remplir la garantie des produits et fournir un service apr s la garantie partout au Canada Caract ristiques et sp cifications de notre gam...

Страница 32: ...p trole liqu fi 6 Dommages caus s par accident m susage abus incendie inondations catastrophe naturelle ou l utilisation de produits non approuv s par Jenn Air 7 R parations aux pi ces ou syst mes dan...

Отзывы: