INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation. 
Read and follow the instructions provided with any tools listed 
here.

Tools needed

Level

Drill with 1¼" (3.0 cm), 

³⁄₈

" (9.5 mm), 

⁷⁄₆₄

" (2.75 mm) and 

¹⁄₈

" (3.0 mm) drill bits

Pilot hole drill bits (determined by chimney support 
attachment method)

Pencil

Wire stripper or utility knife

Tape measure or ruler

Pliers

Caulking gun and weatherproof caulking compound

Vent clamps

Jigsaw or keyhole saw

Flat-blade screwdriver

Metal snips

Phillips screwdriver

Parts needed

Home power supply cable

2 - ½" (12.7 mm) UL listed or CSA approved strain reliefs

3 UL listed wire connectors

For vented installations, you will also need: 

1 wall or roof cap

Metal vent system

For non-vented (recirculating) installations, you will also 
need:

Recirculating Kit Part Number W10272061 for non-vented 
(recirculating) installations only. See “Assistance or Service” 
section to order.

8" (20.3 cm) round metal vent duct. Length required is 
determined by ceiling height. 

Parts supplied

Remove parts from packages. Check that all parts are included.

Hood canopy assembly with ventilator and light bulbs 
installed

Filter - installed in hood canopy

68 - 4 x 8 mm screws

4 - 5 x 45 mm screws

Mounting template

4 vent covers with 4 trim pieces

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.

Have a qualified technician install the range hood. It is the 
installer's responsibility to comply with installation clearances 
specified on the model/serial rating plate. The model/serial rating 
plate is located behind the left filter on the rear wall of the vent 
hood.

Canopy hood location should be away from strong draft areas, 
such as windows, doors and strong heating vents. 

Cabinet opening dimensions that are shown must be used. Given 
dimensions provide minimum clearance.

Grounded electrical outlet is required. See “Electrical 
Requirements” section.

Because of the size and weight of this island hood, the chimney 
support must be securely attached to the ceiling.

For plaster or drywall ceilings, the chimney support must be 
attached to joists. If this is not possible, you must build a 
support structure behind the plaster or drywall. The support 
structure must be able to support 80 lbs (36.6 kg).

The range hood is factory set for venting through the roof.

For non-vented (recirculating) Installation see “Non-vented 
(recirculating) Installations” in “Install Range Hood” section. 
Recirculation Kit Part Number W10272061 is available from your 
dealer or an authorized parts distributor. 

All openings in ceiling and wall where range hood will be installed 
must be sealed.

For Mobile Home Installations

The installation of this range hood must conform to the 
Manufactured Home Construction Safety Standards, Title 24 
CFR, Part 328 (formerly the Federal Standard for Mobile Home 
Construction and Safety, Title 24, HUD, Part 280) or when such 
standard is not applicable, the standard for Manufactured Home 
Installation 1982 (Manufactured Home Sites, Communities and 
Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local 
codes.

Product Dimensions

*Vented installations only

**Non-vented (recirculating) installations only

12

¹⁄₄

"

 

(31.0 cm)

13

³⁄₁₆

"

(33.5 cm)

36" (91.2 cm)

42" (106.4 cm)

*32

¹⁄₂

(82.6 cm)

min.

*46

¹⁄₂

"

 

(118.0 cm)

max.

**32

¹⁄₂

"

 

(82.6 cm)

min.

**52

⁹⁄₁₆

(133.5 cm)

max.

27" (68.6 cm)

Содержание 36" ISLAND CANOPY RANGE HOOD

Страница 1: ...7 or visit our website at www jennair com In Canada call 1 800 807 6777 or visit our website at www jennair ca Instructionsd installationetGuided utilisationetd entretien Au Canada pour assistance ins...

Страница 2: ...M 13 ASSISTANCE OR SERVICE 14 WARRANTY 15 TABLE DES MATI RES S CURIT DE LA HOTTE DE CUISINI RE 16 INSTALLATION REQUIREMENTS 18 Outils et pi ces 18 Exigences d emplacement 18 Exigences concernant l vac...

Страница 3: ...instructions are not followed Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all saf...

Страница 4: ...ire and to properly exhaust air be sure to duct air outside do not vent exhaust air into spaces within walls or ceilings attics or into crawl spaces or garages WARNING TO REDUCE THE RISK OF FIRE USE O...

Страница 5: ...rating plate is located behind the left filter on the rear wall of the vent hood Canopy hood location should be away from strong draft areas such as windows doors and strong heating vents Cabinet open...

Страница 6: ...lking to seal exterior wall or roof opening around the cap The size of the vent should be uniform Cold Weather Installations An additional back draft damper should be installed to minimize backward co...

Страница 7: ...onnection must conform with local codes and industry accepted wiring practices Wire sizes and connections must conform with the rating of the appliance as specified on the model serial rating plate Th...

Страница 8: ...There must be enough conduit and wires from the fused disconnect or circuit breaker box to make the connection in the hood s electrical terminal box NOTE Do not reconnect power until installation is c...

Страница 9: ...s in place 4 Seal all connections with vent clamps MakeElectricalConnection 1 Disconnect power 2 Remove terminal box cover 3 Remove the knockout in the terminal box cover and install a UL listed or CS...

Страница 10: ...od Use section If range hood does not operate check to see whether a circuit breaker has tripped or a household fuse has blown NOTE To get the most efficient use from your new range hood read the Rang...

Страница 11: ...le the lights and the fan motor are Off Heat Sensor The control is equipped with a heat sensor that will turn on the blower to the highest speed if excessive heat occurs around the control area If the...

Страница 12: ...h up on metal filter and release handle to latch into place 6 Repeat steps 1 5 for the other filter Non Vented recirculating Installation Filters The charcoal filter is not washable It should last up...

Страница 13: ...P8 P7 P6 W BK W R GY BK W R BK BU P5 P1 P2 P3 P4A P4 CON3 CON4 CON1 CON2 Electronic Power Board Electronic User Interface CON 6 CON 5 1 2 3 4 5 1 2 3 4 5 6 CON7 CON8 S4 P9 GY N L GND Y G N L CON 11 C...

Страница 14: ...name address and daytime telephone number 2 Appliance model number and serial number 3 Name and address of your dealer or servicer 4 A clear description of the problem you are having 5 Proof of purch...

Страница 15: ...e service by an authorized Jenn Air servicer is not available 10 The removal and reinstallation of your major appliance if it is installed in an inaccessible location or is not installed in accordance...

Страница 16: ...n cas de non respect des instructions Votre s curit et celle des autres est tr s importante Nous donnons de nombreux messages de s curit importants dans ce manuel et sur votre appareil m nager Assurez...

Страница 17: ...que d incendie et vacuer ad quatement les gaz veiller acheminer l air aspir par un conduit jusqu l ext rieur ne pas d charger l air aspir dans un espace vide du b timent comme une cavit murale un plaf...

Страница 18: ...r la paroi arri re de la hotte On doit toujours installer la hotte distance des sources de courant d air fen tres portes et bouches de chauffage Respecter les dimensions indiqu es pour les ouvertures...

Страница 19: ...plus entre deux coudes si on doit utiliser plus d un raccord coud Ne pas installer 2 coudes ensemble Au niveau de chaque jointure du conduit de d charge assurer l tanch it avec les brides de serrage...

Страница 20: ...69 CSA International 8501 East Pleasant Valley Road Cleveland OH 44131 5575 L appareil doit tre aliment par un circuit de 120 V CA seulement 60 Hz 15 A prot g par fusible Si le domicile est quip d un...

Страница 21: ...d Retirer le gabarit 4 Percer 4 avant trous de 4 8 mm pour le montage du support horizontal sup rieur Terminer la pr paration 1 D terminer l emplacement n cessaire pour le c ble d alimentation du domi...

Страница 22: ...une fois la section de conduit en place 4 Utiliser des brides de conduit pour assurer l tanch it de toutes les connexions Raccordement lectrique 1 D connecter la source de courant lectrique 2 ter le...

Страница 23: ...teur de la hotte et de la lampe Voir la section Utilisation de la hotte Si la hotte ne fonctionne pas d terminer si un disjoncteur s est ouvert ou si un fusible du domicile est grill REMARQUE Pour pou...

Страница 24: ...u ventilateur sont teints Capteur de chaleur Le module de commande est quip d un capteur de chaleur qui met le ventilateur en marche la vitesse maximale si la temp rature autour de la zone du module d...

Страница 25: ...a poign e ressort 5 Pousser le filtre m tallique vers le haut et rel cher la poign e pour l embo ter 6 R p ter les tapes 1 5 pour l autre filtre Filtres d installation sans d charge l ext rieur recycl...

Страница 26: ...R GRIS N BL R N BU P5 P1 P2 P3 P4A P4 CON3 CON4 CON1 CON2 Interface utilisateur lectronique CON 6 CON 5 1 2 3 4 5 1 2 3 4 5 6 CON7 CON8 S4 P9 GRIS N L TERRE JA VE N L CON 11 CON 12 BU N L CON 9 CON 10...

Страница 27: ...ez vous de conserver la preuve d achat pour v rifier les conditions de la garantie Si le marchand ou la compagnie de service ne peut pas r soudre votre probl me crivez Jenn Air Brand Home Appliances C...

Страница 28: ...n est pas install conform ment aux instructions d installation fournies 11 Les gros appareils m nagers dont les num ros de s rie et de mod le originaux ont t enlev s modifi s ou qui ne peuvent pas tr...

Отзывы: