JENCO VisionPlus pH618N Скачать руководство пользователя страница 2

  

CONTENTS  

 

 

INITIAL INSPECTION AND ASSEMBLY ...................  2

 

 

BEFORE YOUR FIRST USE ........................…...........  2

 

A.    Replace the Batteries

 ...........................................  2

 

B.    Soak the Electrode

.... ...........................................  2

 

C.    Setup and Calibrate the Electrode and Meter

...........  2

 

 

VISIONPLUS pH 618N OVERVIEW............................  3

 

A.  Meter Description

................................................. 3

 

B.  VisionPlus Graphical Display 

................................ 3

 

 

OPERATION MODES AND KEYPAD OPERATIONS  4

 

A.  Operation Modes

................................................... 4

 

B.  Keypad Operations

 ...............................................   4

 

 

USING VISIONPLUS pH 618N....................................  5

 

A.  Power ON/OFF

 ....................................................    5

 

B.    Set Date and Time

................................................  5

 

C.  Select Buffer

........................................................  6

 

D.  Calibrate pH

.........................................................  6

 

E.  Measure

 ..............................................................   7

 

F.  Hold Data 

........... .................................................   7

 

G.  Save Data 

.................................................…........  7

 

H.    Recall Data and Erase Data

...................................... 7

 

 

ONGOING MAINTENANCE.........................................   8

 

A.  Replace Electrode

.................................................  8

 

 

ERROR DISPLAYS AND TROUBLESHOOTING .......  9

 

 

SPECIFICATIONS ........................................................  10

 

 

WARRANTY ................................................................. 10

 

 

 

 

 

 

 

 

Содержание VisionPlus pH618N

Страница 1: ...Operation Manual MODEL pH 618N Microcomputer Based pH Temperature Pocket Meter pH618N...

Страница 2: ...ption 3 B VisionPlus Graphical Display 3 OPERATION MODES AND KEYPAD OPERATIONS 4 A Operation Modes 4 B Keypad Operations 4 USING VISIONPLUS pH 618N 5 A Power ON OFF 5 B Set Date and Time 5 C Select Bu...

Страница 3: ...nstrument can operate within specifications for approximately2 3 hours after low battery indicator appears 1 Shown in the right figure 2 Take off the battery cover 3 Remove all of the old batteries an...

Страница 4: ...r 5 Electrode ATC assembly Electrode cap is not shown B VisionPlus Graphical Display 1 DATE MM DD YY 2 HOLD mode indicator 3 MEASURE mode indicator 4 CALIBRATION buffer s 5 TIME HH MM 24H format 6 pH...

Страница 5: ...et Mode is used to change date and time 6 Buffer Select Mode Buffer Select Mode is used to select the buffer set which can either be 7 00 7 00 4 01 10 01 or 6 86 6 86 4 00 9 18 B Keypad Operations Key...

Страница 6: ...d Scrolls through stored data Date and Time Set 0 second Decreases current number SCROLL Buffer Select 0 second Selects new buffer set USING VISIONPLUS pH 618N A Power ON OFF Press HOLD key for 2 seco...

Страница 7: ...H meter will perform end point sensing to determine when the calibration reading is stable Meter is calibrated when WAIT icon disappears and the unit will automatically enter the next point calibratio...

Страница 8: ...E and M XX icons will appear indicating the reading has been saved and stored in memory location XX The unit will automatically returns to Measure Mode and ready to perform other task Note The Model p...

Страница 9: ...trode ATC assembly as shown in the right figure 2 Remove the old electrode from the electrode collar 3 Insert a new electrode make sure the electrode fit back into the meter correctly 4 Screw back the...

Страница 10: ...0 00 to14 00pH range Over Range or Recalibrate OVER 0 0 60 0 C pH CAL a pH STAND b pH SLOPE a Offset 7 00pH mV 90mV Offset 6 86pH mV 98 3mV b New slope ideal slope by 30 Use a new buffer solution Repl...

Страница 11: ...Electrode Slope recognition 30 at pH 4 00 4 01 9 18 and 10 01 Input impedance 1012 Temperature Temperature sensor Thermistor 10 k at 25 C Temperature unit Default in factory General Power Meter LR44...

Страница 12: ...protection items must be carefully packed to prevent damage in shipment and insured against possible damage or loss Jenco will not be responsible for damage resulting from careless or insufficient pa...

Страница 13: ...618N TC CHEN 2008 7 20 K618N 01 2009 4 3 02 2009 4 3 01 618 MANUAL 618 09 01 14 P2 09 4 3 P2 5 P8 P10 P11 BAT 09 4 15 3M KCL FOR 2 HOURS...

Отзывы: