JEI GroupLtd
AIRBEAST 35 ATEX
AIRBEAST 35
ATEX Operator’s Manual
10
Then, screw in the feed lever (
1
,
Figure 5).
To mount the lever at the opposite side of
the machine, use 5 mm hex wrench to loosen the screw
2
mounting the head and
reposition the head to the other side, and tighten the screw.
Figure 5.
Method of mounting the feed lever
Mount the annular cutter into the arbor in the manner described before.
Connect the machine to a correctly prepared air supply of sufficient purity using
a hose with the internal diameter of at least 10
mm (0.4’’). The air installation must be
equipped with an air preparation unit: filter, regulator, and lubricator.
Position the machine on a flat ferromagnetic surface (some types of stainless and
acid-proof steel do not conduct magnetic flux) with thickness of at least 10
mm (0.4’’).
The workpiece must be clean, without rust or paint that decrease the holding force of
the magnetic base.
With the MOTOR lever set in the position from Figure 6, enable the magnetic base by
toggling the MAGNET switch to position ON.
2
1