14
Operation Cont.
Figure 14
Figure 15
Figure 16
Receptacles and Extension Cords
Only use high quality, well-insulated, grounded extension
cords in good condition with generator receptacles.
Follow each devices manufacturer’s power rating
recommendation when selecting receptacle and
extension cord.
This generator is equipped
with the following receptacles:
• (4) 120 Volt AC, 20 Amp receptacles
• (1) 120 / 240 Volt AC, 50 Amp receptacle
(NEMA L14-50R)
• (1) 120 / 240 Volt AC, 30 Amp twist lock receptacle
(NEMA L14-30)
• (1)12 Volt 8.3 Amp Output
120 Volt AC, 20 Amp receptacle
• This receptacle has a 20 Amp push-to reset
circuit breaker to protect against overload.
• Each socket is rated to operate 120 Volt, AC,
single phase, 60Hz loads requiring up to 2400
watts (2.4 kW) at 20 Amps.
• Use extension cords having a minimum rating
of 125 Volts AC, 20 Amps.
120 / 240 Volt AC, 30 Amp locking receptacle
• This receptacle has a 30 Amp push-to-reset
circuit breaker to protect against overload.
• This receptacle is rated to operate 120 Volt, AC,
single phase, 60Hz loads requiring up to 3600
watts (3.6 kW) at 30 Amps. It is also rated to
operate 240 Volt AC, single phase, 60Hz loads
requiring up to 7,200 watts (7.2 kW)
• Use a NEMA L14-30 plug with this receptacle.
• Use a 4-wire cord rated for 240 Volts AC, 30
Amps to the plug. You can use the same 4-wire
cord to operate a 120 Volt load.
Voltage selector switch
This switch toggles between 120 volts and 240 volts,
AC output; on the respective receptacles.
Do not connect 3-phase loads to generator.
The 12 Volt 8.3 Amp output is for charging
batteries only!