EQUIPMENT SAFETY

• 

Never place your hands, fingers or other body parts near the compressor’s moving parts during operation. Ensure that the equipment is 
isolated from the power supply and all switches in the 

OFF

 position before carrying out maintenance, repairs or adjustments.    

• 

Never operate this compressor without all guards or safety features in place and in proper working order. If maintenance or servicing requires 
the removal of a guard or safety features, be sure to replace the guards or safety features before resuming operation of the compressor. 

• 

Always wear safety goggles or equivalent eye protection. Compressed air must never be aimed at anyone or any part of the body. 

• 

When not in use, the compressor should be stored in dry place. Keep out of reach of children. Keep children and animals away from the work 
area.  

• 

Clear all work areas of unnecessary tools, debris, furniture etc. prior to use. Cluttered work areas can lead to injuries.   

• 

Do not wear loose clothing or jewellery when operating this equipment. They can be caught in moving parts. Wear protective hair covering to 
contain long hair. 

• 

Follow instructions for lubricating this equipment as required.  

• 

Watch what you are doing and remove any potential distractions before use. Use common sense at all times.  

• 

Do not operate this equipment when you are tired or if you are under the influence of alcohol, drugs or medication that makes you drowsy. 

• 

Check for the correct alignment of moving parts, binding of moving parts, condition of parts, mounting, and air leaks, and any other issues 
that might affect the safe operation of this equipment. A guard or other part that is damaged should be properly repaired or replaced by 
an authorized Jefferson service centre unless otherwise indicated elsewhere in this instruction manual. Have defective pressure switches 
replaced by an authorized service centre. Do not use compressor if the switch does not turn it on and off. 

• 

Operate the compressor according to the instructions provided in this manual. Never allow the compressor to be operated by children, 
individuals unfamiliar with its operation or unauthorized personnel. 

• 

Keep all screws, bolts, and plates tightly mounted. Check regularly.  

• 

The motor air vent must be kept clean so that air can freely flow at all times. Check for dust build-up frequently and clean as required. 
 

• 

If the equipment appears to be operating unusually, making strange noises, or otherwise appears defective, stop using it immediately and 
arrange for repairs by a authorized service centre. 

• 

Solvents such as petrol, thinner, benzine, carbon tetrachloride, and alcohol may damage and crack plastic parts. Do not wipe them with such 
solvents. Wipe plastic parts with a soft cloth lightly dampened with soapy water and dry thoroughly.  

• 

Only use Jefferson approved replacement parts. Non-approved parts will void your warranty and can lead to malfunction and resulting 
injuries. Genuine parts are available from Jefferson your dealer. 

• 

Do not modify the compressor for any use other than which it was designed for by the manufacturer.  Do not tamper with or attempt to adjust 
the tank, pressure switch or safety valve. Never strap anything to the tank. Do not subject the tank to impact, vibration, heat, abrasion or 
corrosive materials. 

• 

Always contact an authorized service centre for advice on any repairs. Unauthorized modification may not only impair the compressor 
performance but may also result in accident or injury to repair personnel who do not have the required knowledge and technical expertise to 
perform the repair operations correctly. 

• 

When the compressor is not in use, ensure the pressure switch is turned off, disconnect the equipment from the power source and open the 
drain cock to discharge the compressed air from the air tank. 

• 

To reduce the risk of burns, do not touch tubes, heads, cylinder and motors. During or immediately after use. Allow equipment to cool down 
before carrying out maintenance, repairs or adjustments.  

• 

Never direct the output jet of air at persons or animals. Ensure air supply valve is turned 

OFF

 before disconnecting the air supply hose. 

• 

Read the all safety instructions for any tool or accessory used with the compressor and ensure the safe working pressure of any appliance 
used exceeds the output pressure of the compressor. If you are using a spray gun it is important to ensure that the work area has sufficient 
ventilation in place.   

• 

Do not operate in the vicinity of flammable liquids, gases or solids.   

• 

Do not operate the compressor without an air filter or restrict the air flow around the equipment. 
 

• 

When the compressor is not in use ensure that it is switched off, disconnected from the power supply and the air and moisture drained from 
the tank. 

Содержание JEFC150L10B-230

Страница 1: ...User Manual v 2 1 JEFC150L10B 230 AIR COMPRESSOR 150L 230V 50Hz 10Bar 3HP BELT DRIVE ...

Страница 2: ...USER MANUAL JEFC150L10B 230 150L AIR COMPRESSOR 230V 50Hz 3HP 10Bar BELT DRIVE www jeffersontools com 2 ...

Страница 3: ...ification 6 Before First Use 7 Safety Guidelines 8 Warning Labels 10 Safety Valve 11 Operation Guide 11 Maintenance 13 Troubleshooting 14 Environmental Protection 15 WEEE Waste Electrical and Electronic Equipment Statement 15 Parts Diagram Main Assembly 16 Parts List Main Assembly 17 Parts Diagram Pump 18 Parts List Pump 19 EC Declaration of Conformity 20 Limited Warranty Statement 21 CONTENTS ...

Страница 4: ...ion Manual is designed to assist you in the safe operation and maintenance of the compressor Some illustrations in this Instruction Manual may show details or attachments that differ from those on your own compressor Contact your nearest Jefferson Dealer if you are unsure about any information included in this manual or require any additional information about the safe use operation maintenance or...

Страница 5: ...internal pressure can expel the bung along with oil from the head possibly leading to damage PLEASE NOTE THE FOLLOWING PHOTOGRAPHS INSTRUCTIONS ARE FOR REFERENCE ONLY AND MAY DIFFER FOR YOUR COMPRESSOR MODEL PLEASE CONTACT JEFFERSON TOOLS IF YOU NEED ANY ADVICE ON THE ASSEMBLY PROCEDURE Position the compressor on a flat surface or with a maximum permissible inclination of 10 Fig 3 in a well aired ...

Страница 6: ... Gauge 11 Pressure Regulator 3 Air Outlet Quick Release 12 Pressure Gauge 4 Pressure Switch 13 Check Valve 5 Transportation Handle 14 Tank Rating Plate 6 Belt Guard 15 Ball Valve 7 Motor Assembly 16 Back Wheels 8 Air Filter 17 Tank Drain Valve 9 Pump Assembly 18 Front Castors 1 EQUIPMENT IDENTIFICATION 2 3 4 5 6 7 9 10 8 11 12 13 15 14 16 17 18 ...

Страница 7: ...itable for use This compressor must be used on a flat level surface The maximum safe operating angle in any direction is 15 degrees see Fig 8 Do not operate the compressor on inclines in excess of 10 degrees Serious damage to pump components may result from insufficient lubrication Never use the air compressor on a rooftop or elevated position that could allow the unit to fall or be tipped over Us...

Страница 8: ...gularly and tested to ensure that it is safe for use Portable equipment means any electrical item that can be moved and this is often referred to as Portable Appliance Testing PAT PAT testing should be carried out regularly on this equipment by trained authorised personnel as required by the legislation The Health and Safety at Work Act 1974 states that it is the responsibility of the owner of ele...

Страница 9: ...tor air vent must be kept clean so that air can freely flow at all times Check for dust build up frequently and clean as required If the equipment appears to be operating unusually making strange noises or otherwise appears defective stop using it immediately and arrange for repairs by a authorized service centre Solvents such as petrol thinner benzine carbon tetrachloride and alcohol may damage a...

Страница 10: ...aint in a confined area with the air compressor Operate the air compressor in well ventilated areas free from obstructions Equip areas with fire extinguishers suitable for electrical fires Do not leave nylon material shirts or jumpers on the compressor Store paint thinners and other flammable liquids in approved containers in a secure location away from the work area Minimum clearance 0 5m Maximum...

Страница 11: ...mum torque of 30Nm paying attention not to cause any deformation using pincers pliers hammers or tools other than a hexagonal spanner is forbidden and will void warranty Check that the inlet hole and the shutter are not blocked by glue Teflon or similar materials that could bind the shutter or other functional components If the valve is replaced the compressed air contained in the system must be d...

Страница 12: ...zero to help prolong the life of the regulator and avoid damage AIR LINE CONNECTION The compressor comes equipped with a quick in line female connector To insert a male connector pull the collar backwards and insert the male connection When fully inserted release the collar If a different style of connection is required the connector can be replaced NOTE When fitting the replacement ensure the thr...

Страница 13: ...ighten this nut securely you can use some PTFE tape on the thread to help create a tighter seal before tightening Fill the oil reservoir with a compatible compressor oil e g Jefferson HT68 Compressor Oil Checking Cleaning the Air Filter Ensure the compressor is turned off and disconnected from the power source Allow the compressor pump and other parts to cool off if changing filter after use Unscr...

Страница 14: ...rised service agent There is a leak from the base of the pressure switch when the compressor is stopped The non return valve from the tank is leaking Disassemble and clean if necessary replace valve insert Contact your authorised service agent The compressor is noisy with metallic clangs knocks Bearing or piston problem Low oil level Stop the compressor and contact a specialized service technician...

Страница 15: ...rwise arise from inappropriate waste handling Please contact your local authority for further details of your nearest designated collection point Penalties may be applicable for incorrect disposal of this waste in accordance with you national legislation For business users in the European Union If you wish to discard electrical and electronic equipment please contact your dealer or supplier for fu...

Страница 16: ...USER MANUAL JEFC150L10B 230 150L AIR COMPRESSOR 230V 50Hz 3HP 10Bar BELT DRIVE www jeffersontools com 16 PARTS DIAGRAM MAIN ASSEMBLY ...

Страница 17: ... 1 Drain Ball Valve 37 1 PL Washer 11 1 Ball Valve 38 1 Hex Nut 12 1 Pressure Regulator 39 1 Pump 13 1 Pressure Gauge 40 1 Bracket 14 3 Quick Coupler 41 1 Hex Bolt 15 1 Bonnet 42 1 Hex Bolt 16 1 Spring Check valve 43 1 Motor Pulley 17 1 Valve Element 44 1 Key 18 1 O Ring 45 1 Hex Nut 19 1 Check Valve 46 1 PL Washer 20 1 Check Valve 47 4 Bolt 21 1 Elbow Fitting 48 1 Motor 22 1 Tuve Nut 49 1 Handle ...

Страница 18: ...USER MANUAL JEFC150L10B 230 150L AIR COMPRESSOR 230V 50Hz 3HP 10Bar BELT DRIVE www jeffersontools com 18 PARTS DIAGRAM PUMP ...

Страница 19: ... 1 Nipple 8 1 Front Support 32 2 Hex Bolt 9 2 Gasket 33 2 Sp Washer 10 2 Bearing 34 1 Radiator 11 1 Crankshaft 35 1 Gasket Radiator 12 2 Connecting Rod 36 6 Hex Socket Bolt 13 4 Circlip 37 1 Air Filter Assembly 14 2 Piston Pin 37 1 1 Case 15 2 Piston 37 2 1 Element 16 2 Oil Ring 37 3 1 Case 17 2 Oil Ring 38 1 Cylinder Head 18 2 Compression Ring 39 1 Cylinder Head Gasket 19 2 Piston Ring Kit 40 1 V...

Страница 20: ... Directive 2014 29 EU as amended Simple Pressure Vessels Directive Technicka Inspekcia A s Trnavska Cesta 56 821 01 Bratislava Country Slovakia 1354 Equipment Category Air Compressor Item 8 Product Name Model 150L Air Compressor JEFC150L10B 230 150L Air Compressor 230V 3HP 10Bar Belt Drive Measured Sound Power Level Guaranteed Sound Power Level 96dB 96dB The conformity assessment procedure followe...

Страница 21: ...it eliminates the need to provide proof of purchase should a warranty claim be necessary Warranty Repair Should Jefferson confirm the existence of any defect covered by this warranty the defect will be corrected by repair or replacement at an authorized Jefferson dealer or repair centre Packaging Freight Costs The customer is responsible for the packaging of the equipment and making it ready for c...

Страница 22: ...e and in need of repair and any repairs needed are covered by the warranty policy In order to qualify for warranty cover all equipment presented must have been used serviced and maintained as instructed in the user manual Where repair is not covered by the warranty a quotation for repair labour costs and return delivery will be sent to the customer normally within 7 working days NOTE If the repair...

Страница 23: ...USER MANUAL JEFC150L10B 230 150L AIR COMPRESSOR 230V 50Hz 3HP 10Bar BELT DRIVE www jeffersontools com 23 ...

Страница 24: ...s Park Chester United Kingdom CH4 9QR Tel 44 0 1244 646 048 Email sales jeffersontools com IMPORTANT SAFETY FIRST Before attempting to use this product please read all the safety precautions and operating instructions outlined in this manual to reduce the risk of fire electric shock or personal injury www jeffersontools com www jeffersontools com ...

Отзывы: