background image

S

YSTEM CONNECTIONS

6

              

  

BALANCED OUTPUTS

BALANCED INPUTS

RM2 RM1 EM

CON INPUT 24V

DC POWER

4

3

2

1

PGM

RM1

RM2

4

3

2

1

EM

SERIAL NO.

MODEL NO.: JSE-174A

SIGNAL EXCHANGER

MADE IN KOREA

JPA-480DP

JSE-174A

G

G

G

G

G

MADE IN KOREA

DATA RECEIVER

MODEL NO.: JDR-104

DATA OUT

TO JRG-220A

SUMMING

AUDIO OUT

SERIAL NO.:

RM 4 

AUDIO IN

RM 3 

AUDIO IN

RM 2 

AUDIO IN

RM 1 

AUDIO IN

RM 4 

DATA IN

RM 3 

DATA IN

RM 2 

DATA IN

RM 1 

DATA IN

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

WARNING: 

TO REDUCE THE RISK OF  FIRE

OR ELECTRIC SHOCK DON'T EXPOSE THIS

EQUIPMENT TO RAIN OR MOISTURE. 

JEDIA CO.,LTD

FD-20 SLOT

Priority

Relay

C

O

M

N

.O

N

.C

Ground

Lift

AC POWER

REMOTE

G

C

O

M

25

V

50

V

10

0V

C

O

M

1.

3

5.

2

20

.8

AC 230V   /50Hz 1420W

DC POWER 

24V/40A 

Balanced Outputs

RMS 480W

SERIAL NO.:

MODEL.: JPA-

1 CHANNEL P.A POWER AMPLIFIER

MADE IN KOREA

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

WARNING:

TO REDUCE THE RISK OF FIRE

OR ELECTRIC SHOCK DON'T EXPOSE THIS

EQUIPMENT TO RAIN OR MOISTURE.

480DP

G

G

Off : 

Fault

On :

Normal

GND

OUT

PRI

CTL

24V

400Hz

Normal

 FD20

Max 0.5A

0dBu(0.775V)

Priority Input

60k    BAL

0dBu(0.775V)

PGM Input

60k    BAL

Le

ve

l

0

10

JMA-5104

JCS-110A

J6CD-10

JDR-104

JSS-5120

8

DIGI LINK

SELECTOR

DC INPUT

REC OUT

LINE IN

OUTPUT 1

OUTPUT 2

OUTPUT 3

OUTPUT 4

MIC/

LINE

MIC/

LINE

MIC/

LINE

MIC/

LINE

MIC/

LINE

MIC/

LINE

MIC/

LINE

MIC/

LINE

MIC/

LINE

MIC/

LINE

INPUT 9

INPUT 8

INPUT 7

INPUT 6

INPUT 5

INPUT 4

INPUT 3

INPUT 2

INPUT 1

INPUT 10

7

3

1

9

10

4

2

1

3

2

4

4

3

2

1

UNIT NO. RESET

RS-232C

IN

OUT

24V

SERIAL NO.:

MODEL: JMA-5104

MADE IN KOREA

MAIN SIGNAL CONTROLLER

C

A

U

TI

O

N

RI

SK

 O

EL

EC

TR

IC

 S

HO

CK

DO

 N

OT

 O

PE

N

WA

RN

IN

G:

TO

 R

ED

UC

TH

RI

SK

 O

FI

RE

OR

 E

LE

CT

RI

SH

OC

DO

N'

EX

PO

SE

 T

HI

S

EQ

UI

PM

EN

TO

 R

AI

O

M

O

IS

TU

RE

.

REMOTE ALL IN 

TO J6CD-10

5V~24VDC

SERIAL NO.:

TO JRG-220A

SPEAKER SELECTOR OUT

TO JRG-220A

REMOTE ZONE DATA IN

REMOTE CONTROL

UNIT NO.

RESET

IN

OUT

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

WARNING:

TO REDUCE THE RISK OF FIRE

OR ELECTRIC SHOCK DON'T EXPOSE THIS

EQUIPMENT TO RAIN OR MOISTURE.

MADE IN KOREA

MODEL NO.: JSS-5120

SPEAKER SELECTOR

with DIGITAL MATRIX

1 2 3 4 5 6 7 8

9 10 11 12 13 14 15

CAUTION:

 

FIRE REPLACE ONLY WITH SAME TYPE FUSE. 

R

L

MONO

OUTPUTS

STEREO

SERIAL NO.:

REMOTE CONTROL

BAL 0.775V 600 

UNBAL 0.775V 600 

WARNING:

TO REDUCE THE RISK OF FIRE

OR ELECTRIC SHOCK DON'T EXPOSE THIS 

EQUIPMENT TO RAIN OR MOISTURE. 

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

1

PO

W

ER

 O

  O

FF

2

PL

AY

   

PA

US

E

3

DI

SC

 U

P

4

TR

AC

DO

W

N

5

TR

AC

UP

6

DI

SC

 D

OW

N

7

EJ

EC

T

8

RA

ND

OM

9

SC

AN

10

RE

PE

AT

11

ST

OP

12

+1

2V

13

GN

14 15

GN

6CD CHANGER

MADE IN KOREA

MODEL NO.: J6CD-10

DC POWER

      24V  1.5A

FUSE RATING

T0.5A 250V

AC 220V    60Hz 11W 

TO REDUCE THE RISK OF

CHIME

REMOTE

RISK OF ELECTRIC SHOCK

DO NOT OPEN

CHIME & SIREN

MADE IN KOREA

MODEL NO.: JCS-110A

WARNING: 

TO REDUCE THE RISK OF  FIRE 

OR ELECTRIC SHOCK DON'T EXPOSE THIS

EQUIPMENT TO  RAIN OR MOISTURE.  

CAUTION

0

10

0

10

CHIME

U

P

D

O

W

N

G

N

D

SERIAL NO.:

CAUTION:

 

TO  REDUCE  THE  RISK  OF

FIRE REPLACE ONLY WITH SAME TYPE FUSE.

SIREN

DC POWER

AC 220V    60Hz

3.5W

FUSE RATING

F0.2A 250V

SPEAKERS

JPD-322A

JRG-220A

PC

JRA-051A#1

JRA-051A#4

MIC

Содержание JMA-5104

Страница 1: ...WWW JEDIA COM JMA 5104 MAIN SIGNAL CONTROLLER...

Страница 2: ...60 16 60 16 60 16 60 16 60 16 60 16 60 16 60 16 60 16 60 16 MAIN SIGNAL CONTROLLER JMA 5104 H M L H M L H M L CH 10 OUTPUT 1 CH 9 CH 8 CH 7 CH 6 CH 5 CH 4 CH 3 CH 2 CH 1 TRIM TRIM TRIM TRIM TRIM TRIM...

Страница 3: ...Slide volumes TRIM volumes of front panel Turn on the Power switch to operate Connect CDP Cassette Deck and Microphones to Input channels and adjust the input gains with each TRIM volume Select the M...

Страница 4: ...h is to supply Power to equipment When power is on power LED is lighting This LED indicator is to show excessive input signal This LED is lighting when the input signal reaches a level 3dB below the o...

Страница 5: ...l This LED indicator is to show output signal present at the channel output This controller is to adjust the tone of output signal by 3 Band EQ HIGH 12dB at 10kHz MID 12dB at 1kHz LOW 12dB at 100Hz Th...

Страница 6: ...T CONNECTOR 2 MIC LINE SELECTOR 3 DC INPUT 4 STEREO LINE IN 5 REC OUT 6 MASTER OUTPUT 7 SELECTOR 8 DIGI LINK 1 2 3 4 6 7 8 9 10 11 5 1 2 3 4 R EAR PANEL CONTROLLS 8 DIGI LINK SELECTOR DC INPUT REC OUT...

Страница 7: ...TA PORT This switch is to assign the number address of the equipment itself Setup method summing up the value of ON switch number from 1 up to 15 Legend This switch is to initialize the equipment This...

Страница 8: ...2 4 4 3 2 1 UNIT NO RESET RS 232C IN OUT 24V SERIAL NO MODEL JMA 5104 MADE IN KOREA MAIN SIGNAL CONTROLLER CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHO...

Страница 9: ...edance MASTER OUT 1 4CH REC OUT 1 4CH Input sensitivity Impedance MIC 1 10 CH LINE 1 10 CH T H D Frequency Response 1 3dB Residual Noise Cross Talk Data communication Method Data communication speed N...

Страница 10: ...8 B LOCK DIAGRAM 4 BUS TRIM VR MCU DIGI LINK Non contacting switch UART PC TRIM VR MATRIX CONTROL 3 BAND EQ OUTPUT REC OUT MASTER VR MASTER VR LEVEL PEAK LEVEL PEAK OUTPUT VR CONTROL 3 BAND EQ 4EA 4EA...

Страница 11: ...MEMO 9...

Страница 12: ...JMA 5104 OPERATING INSTRUCTIONS 4M OP207010 MAIN SIGNAL CONTROLLER 07 01 08...

Отзывы: