E/M, R/M, TEL PWR CON
L
N
E
24V/1.5A
DC OUTPUT
24V/1.5A
SWITCHED TOTAL MAX OUTPUT 7000VA. SWITCHED EACH MAX OUTPUT 3500VA.
DC 24V
EQUIPMENT
ONLY.
DC 24V OUTPUT
SERIAL NO.:
(TO JRG-220A)
(TO JEP-352)
POWER OUTPUTS DELAY SOCKET(1 6) FOR POWER AMPLIFIERS.
UNSWITCHED MAX 360VA
9
8
7
6
5
4
3
2
1
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
230V / 50Hz
24V
SWITCHED IN
PWR CONTROL IN
UNSWITCHED IN
TO OTHER
JPD-322A
WARNING:
TO REDUCE THE RISK OF
FIRE OR ELECTRIC SHOCK DO NO T EXPOSE
THIS EQUIPMENT TORAIN OR MOISTURE.
MODEL NO.: JPD-322AU
POWER CHECK
(NON PULSE)
DC OUTPUTS
T40AL 32V
T40AL 32V
T20AL 32V
T20AL 32V
T20AL 32V
CAUTION:
IN CASE OF USING EXTERNAL
EXTERNAL
BATTERY
24V
CAUTION:
TO REDUCE
THE RISK OF
FIRE REPLACE ONLY WITH SAME TYPE FUSE.
SERIAL NO.:
UNSWITCHED OUT
1
2
3
4
5
EMERGENCY POWER SUPPLY
MADE IN KOREA
MODEL NO.: JEP-352U
WARNING:
TO REDUCE THE RISK OF FIRE
OR ELECTRIC SHOCK DON'T EXPOSE THIS
EQUIPMENT TO RAIN OR MOISTURE.
24V
SWITCHED OUT
PWR CONTROL OUT
(FROM JPD-322A)
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
FUSE RATING
T2AH 250V
AC 230V 50Hz 105W
BATTERY, INTERNAL BATTERY IS NOT AVAILABLE.
BE SURE NOT TO EXCEED 24A OF DC OUTPUTS
FOR USING OF INTERNAL BATTERY.
EACH
24V/32A
EACH
24V/16A
POWER
CHECK
AKU 40%
CHECK
(NON PULSE)
(NON-PULSE)
USE ONLY WITH A 250V FUSE
40
40
20
20
20
E M SPEAKER SELECTOR
MADE IN KOREA
MODEL NO.: JES-120AU
CAUTION
WARNING:
TO REDUCE THE RISK OF FIRE
OR ELECTRIC SHOCK DON'T EXPOSE THIS
EQUIPMENT TO RAIN OR MOISTURE.
RISK OF ELECTRIC SHOCK
DO NOT OPEN
LINK
TO JRG-220A
DATA OUT
EXTENSION
2019 18 1716 15 14 13 12 11
10 9 8 7 6 5 4 3 2 1
S/N
TO JEU-211A
+24V
GND
OUT
E/M ALL OUT(+5V)
+5VDC/0.25A OUT
IN
OUT EXTENSION
FIRE DETECTOR INPUT
E/M ALL OUT(+5V)
POWER CHECK
TX CHECK
(NON PULSE)
(PULSE)
EMERGENCY MESSAGE CARD
LEAK
10
LEVEL
LEVEL
LEAK
10
MODEL.: JEU-211AU
EMERGENCY UNIT
MADE IN KOREA
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
WARNING:
TO REDUCE THE RISK OF FIRE
OR ELECTRIC SHOCK DON'T EXPOSE THIS
EQUIPMENT TO RAIN OR MOISTURE.
FROM
JES-120A
BAL
1.23V 600
SERIAL NO.:
E/
M
A
LL
IN
24
V
G
N
D
IN
E/M AUDIO
OUTPUT
SIREN
FAULT CHECK
(NON PULSE)
FIRE CHECK
(NON PULSE)
S
YSTEM CONNECTIONS
(시스템 연결 방법)
LEVEL
DATA OUT
AUDIO OUTPUT
BAL 1.23V 600W
CHIME
MIC
SERIAL NO.:
CAUTION
WARNING:
TO REDUCE THE RISK OF FIRE
OR ELECTRIC SHOCK DON'T EXPOSE THIS
EQUIPMENT TO RAIN OR MOISTURE.
RISK OF ELECTRIC SHOCK
DO NOT OPEN
G
POWER
ON
OFF
REMOTE AMPLIFIER
MADE IN KOREA
MODEL NO.: JRA-051A
10
0
10
LEAK
JRA-051A #1
LEVEL
DATA OUT
AUDIO OUTPUT
BAL 1.23V 600W
CHIME
MIC
SERIAL NO.:
CAUTION
WARNING:
TO REDUCE THE RISK OF FIRE
OR ELECTRIC SHOCK DON'T EXPOSE THIS
EQUIPMENT TO RAIN OR MOISTURE.
RISK OF ELECTRIC SHOCK
DO NOT OPEN
G
POWER
ON
OFF
REMOTE AMPLIFIER
MADE IN KOREA
MODEL NO.: JRA-051A
10
0
10
LEAK
JRA-051A #2
G
LINK
INPUT
REMOTE AUDIO IN
REMOTE ZONE DATA OUT
AMP PRIORITY CONTROL OUT
REMOTE DATA
FROM JDR-104 / JRA-051A
FROM JSS-120A
REMOTE-1 CARD
20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
G
DIRECT SPEAKER SELECTOR DATA IN
TELEPHONE PAGING CARD
TEL AUDIO IN
+5V OUT
10 9 8 7 6 5 4 3 2 1
20 19 18 17 16 15 14 13 12 11
UPPER JRG-220A
G
E/M DATA
E/M
LINK
INPUT
G
FROM JSS-120A
TO RELAY BOX
LOWER JRG-220A
FROM JPD-322A
AUDIO
IN
AUDIO
OUT
N.
O
CO
M
+2
4V
OUT
EMERGENCY CARD
E/M
G
ND
G
G
G
G
G
MADE IN KOREA
DATA RECEIVER
MODEL NO.: JDR-104
TO JRG-220A
DATA OUT
SUMMING
AUDIO OUT
SERIAL NO.:
RM 4
AUDIO IN
RM 3
AUDIO IN
RM 2
AUDIO IN
RM 1
AUDIO IN
RM 4
DATA IN
RM 3
DATA IN
RM 2
DATA IN
RM 1
DATA IN
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
WARNING:
TO REDUCE THE RISK OF FIRE
OR ELECTRIC SHOCK DON'T EXPOSE THIS
EQUIPMENT TO RAIN OR MOISTURE.
TO JRG-220A
TO JRG-220A
REMOTE ALL IN
5V~24VDC
SPEAKER SELECTOR OUT
REMOTE ZONE DATA IN
SERIAL NO.:
ACTIVE SPEAKER SELECTOR
MADE IN KOREA
MODEL NO.: JSS-120A
CAUTION
WARNING:
TO REDUCE THE RISK OF FIRE
OR ELECTRIC SHOCK DON'T EXPOSE THIS
EQUIPMENT TO RAIN OR MOISTURE.
RISK OF ELECTRIC SHOCK
DO NOT OPEN
JEU-211AU
(JEU-211A)
JCU-160
JSS-120A
JDR-104
JRG-220AU
(JRG-220A)
JEP-352U
(JEP-352)
JPD-322AU
(JPD-322A)
TO ÒDÓ TYPE POWER AMP
PRIORITY IN
TO ÒDÓ TYPE POWER AMP
PRIORITY CONTROL IN
JES-120AU
(JES-120A)
FIRE SENSOR
POWER CHECK
(NON PULSE)
JCU-160
IN
OUT
RS-232C
UNIT NO. RESET
DC INPUT
SUM OUTPUT
24V
INPUT
CHECK SIGNAL
CH 1
CH 2
CH 3
CH 4
CH 5
CH 6
CH 7
CH 8
CH 9
1
8
CH 10
CH 11
CH 12
CH 13
CH 14
CH 15
CH 16
1
8
9
16
9
16
NON PULSE
PULSE
CHANNEL USE
OFF
ON
7