SAFETY INSTRUCTIONS

FEATURES

Read all safety instruction before operating the JEU-211AU.
1. Install equipment as follow conditions.

AUTO ALERT(ALARM) OF FIRE

The apparatus shall not be exposed to dripping or splashing and 

no object filled with liquids, such as vases, shall be place on the 

apparatus.       

Install at the place, not bending curved.

Do not install this apparatus in a confined space such as a book 

case or similar unit.

Locate this apparatus away from heat source, such as radiators

or other device that produce heat. 
Do not drop objects or spill liquids into the inside of the apparatus.

2. Keep in mind the following when connecting the apparatus.

Connect the apparatus after reading of O/P manuals.

Connect each connection of amplifier perfectly, if not, it maybe

Caused hum, damage, electric shock in case of mis-connecting. 
To prevent electric shock, do not open top cover.
Connect the power cord with safety after check of AC power.

This apparatus should be serviced by qualified service person.

안 전 사 항

특징

제품을 운용하기전에 모든 안전사항을 읽어 보십시오.

1. 이런 장소에 설치하여 주십시오.

화재 발생시 자동경보

진동이나 경사가 심하지 않고 바닥이 평평한 장소.

통풍이 잘되고 물기나 습기가 많지 않은 장소.
직사광선을 받지 않는 장소 또는 난방기구(발열체)에서 멀리 떨어진
장소.
인화성 물질(화학약품)이 없는 장소.

2. 설치시 이런점을 주의하십시오.

사용설명서 시스템 연결방법을 완전히 읽으신 후에 연결해 주십시오.

각종 연결선을 완전하게 연결해 주십시오.

(주전원 코드를 뽑은 상태에서 연결.)

불완전한 연결은 잡음, 제품의 손상 또는 안전사고의 원인이 됩니다.

전기적 충격 또는 감전사고의 위험이 있으므로 뚜껑을 열지 말아주십
시오.
주 교류 전원 플러그를 연결하기 전에 사용전압을 확인하신 후 안전
하게 연결하십시오.

제품을 수리시는 규정된 부품과 자격이 있는 사람이 수리를 하여야 함.

1

화재 자동 경보기와 연결하여 화재가 발생하면 자동으로 경보를 울려
주며, 화재표시 LED가 점멸하게 됩니다.

점검 및 시험운용 기능
JES-120AU, JES-120A와 연결한 후 JES-120AU, JES-120A의
스위치를 선택하면 점검 및 시험운용을 할 수 있습니다.

무인 자동방송 기능(선택사양)
E/M MESSAGE CARD를 장착하면 화재 발생시 초기에 사이렌이 방송
되고 일정시간(약10초)이 지나면 E/M MESSAGE가 무한 방송됩니다.
또한 E/M MESSAGE CARD를 장착하지 않으면 자동으로 사이렌이 계
속 방송됩니다.

It should be connected with 'five auto alam' and if fire broke out, 

automatically alarming and flashing of fire indicator.

OPERATING & INSPECTION

Connect with JES-120AU, JES-120A and select S/W of 

JES-120AU, JES-120A to check of this unit.

AUTO ANNOUNCEMENT WITHOUT PERSON(OPTION)

Firstly, siren ringing for 10sec and E/M message is followed 

continuously by E/M message card(option).

Without E/M message card : Only siren

The apparatus shall not be exposed to dripping or splashig

and no object filled with liquids, such as vases, shall be

place on the apparatus

이 기계(장치)는 물기에 접촉(물에 적시는 정도의 접촉)해서는 안되며
꽃병과 같은 액체가 담겨진 물체를 기계 가까이 두는것을 금지하여야
합니다.

본 장비는 유럽 소방안전 규격인 EN 60849의 규정에 준하여 본장비의
주요기능을 검출하여 이상발생시 본사의 JCU-160장비에 알려주어
장비의 이상 유무 상태를 유지 관리 할 수 있는 기능을 가지고 있다.

유럽 소방안전 규격 EN60849적용

Compliance with IEC 60849

This equipment is designed for compliance with IEC 60849 standard.

So this equipment has a function to report major features of this 

equipment to JCU-160.

Therefore when there is something wrong of major features of this

 equipment, it can be checked by JCU-160

Содержание JEU-211AU

Страница 1: ...WWW JEDIA COM EMERGENCY UNIT JEU 211AU ...

Страница 2: ...AR PANEL CONTROLS C F R 1 1 1 2 3 4 6 MERGENCY MESSAGE CARD 선택사양 E FIRE EMERGENCY UNIT JEU 211A DYNAMIC Micro phone DM A 500 KUN HYUNG ELECTRONIC CO LTD 8 9 7 YSTEM CONNECTIONS 시스템 연결 방법 S PECIFICATIONS S LOCK DIAGRAM B OFF ON LEVEL FAULT LEAK 10 BUZZER BUZZER MIC ...

Страница 3: ...는 안전사고의 원인이 됩니다 전기적 충격 또는 감전사고의 위험이 있으므로 뚜껑을 열지 말아주십 시오 주 교류 전원 플러그를 연결하기 전에 사용전압을 확인하신 후 안전 하게 연결하십시오 제품을 수리시는 규정된 부품과 자격이 있는 사람이 수리를 하여야 함 1 화재 자동 경보기와 연결하여 화재가 발생하면 자동으로 경보를 울려 주며 화재표시 LED가 점멸하게 됩니다 점검 및 시험운용 기능 JES 120AU JES 120A와 연결한 후 JES 120AU JES 120A의 스위치를 선택하면 점검 및 시험운용을 할 수 있습니다 무인 자동방송 기능 선택사양 E M MESSAGE CARD를 장착하면 화재 발생시 초기에 사이렌이 방송 되고 일정시간 약10초 이 지나면 E M MESSAGE가 무한 방송됩니다 또한 E M MES...

Страница 4: ...ompletely to the clockotherwise 5 MICROPHONE CONNECTOR Microphone is unidirectional dynamic microphone Push the switch in the side when you use it If unplug connector or microphone fault buzzer will make warning sound with LED flashing 화재가 발생시 화재를 표시하는 LED로서 점멸하게 됩니다 2 부저 ON OFF 스위치 마이크 결함 케이블 단선 쇼트 마이크 유니트 고장 콘넥터 접촉불량 등 이 발생할 경우에 부저가 울리게 됩니다 스위치를 OFF 로 할 경우에는 마이크 결함이 발생하여도 부저가 울리지 않게 됩니다 항상 ON 위치...

Страница 5: ...is is volume for siren check and adjust volume 2 LEVEL CONTROL OF SIREN This is output connector of valance type This is connector should be connected with E M audio in of E M card JRG 220AU JRG 220A 3 E M AUDIOOUTPUT CONNECTOR This is for mounting without E M message card 4 BLANK PANEL This is volume control for E M message Check and adjust volume 5 E M MESSAGE VOLUME CONTROL OPTION This card is ...

Страница 6: ... 3 E M MESSAGE CARD를 BLANK에 삽입하고 SCREW로 고정한다 EMERGENCY MESSAGE CARD LEAK 10 U4 CN2 LEVEL LEAK 10 MODEL JEU 211AU EMERGENCY UNIT MADE IN KOREA RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DON T EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE FROM JES 120A BAL 1 23V 600 SERIAL NO E M ALL IN 24V GND IN E M AUDIO OUTPUT SIREN FAULT CHECK NON PULSE FIRE CHECK NON PU...

Страница 7: ...not be deleted before The previous announcement is an automatically overwritten 중요사항 현재 녹음된 메시지를 새로운 메시지로 교환하고자 녹음할 때는 전에 녹음된 메시지는 지울 필요가 없으며 자동으로 덮어 씌워집니다 1 Set the switch AUTO MANUAL to MANUAL 2 Set the switch PLAY REC to REC 3 Set the switch MIC LINE according to the input signal used For a microphone to position MIC For a unit with line level e g cassette recorder CD player to position LINE 4 ...

Страница 8: ...ith headphones while replaying 재생 진행중 방송 내용을 모니터하기 위해 헤드폰을 사용할 수 있습니다 CD PLAYER Cassette Recorder Microphone Headphone VR2 LEVEL MIC LINE CN2 BLK BRN RED ORG YEL GND POWER SUPPLY 24V CONTROL AUDIO E M IN GND 24V H P BLK OR BRN RED ORG YEL From JEU 211AU JEU 211A Inputs MIC 50dB 600 Unbal LINE 10dB 10k Unbal Operating Voltage 24VDC Current Consumption NOR 30mA MAX 70mA Message Recording Time Max 60...

Страница 9: ...K NON PULSE FIRE CHECK NON PULSE SYSTEM CONNECTIONS 시스템 연결 방법 LEVEL DATA OUT AUDIO OUTPUT BAL 1 23V 600W CHIME MIC SERIAL NO CAUTION WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DON T EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE RISK OF ELECTRIC SHOCK DO NOT OPEN G POWER ON OFF REMOTE AMPLIFIER MADE IN KOREA MODEL NO JRA 051A 10 0 10 LEAK JRA 051A 1 LEVEL DATA OUT AUDIO OUTPUT BAL 1 23V 600W ...

Страница 10: ...nced Frequency Response Less Than 3dB 200Hz 10KHz Signal to Noise Ratio More Than 60dB T H D Less Than 0 5 200Hz 10KHz GENERAL Power Consumption 3 5W Power Source DC 24V E M MESSAGE Recording Time Basic 16SEC ROM 1 Extended 32SEC ROM 1 2 Sampling Frequency 16KHz Frequency Response Less Than 3dB 200Hz 6 4KHz SIREN Siren Frequency 800Hz 파상 Dimensions Weight kg lbs 3 6 6 483 W x 88 H x 200 D mm 19 W ...

Страница 11: ...ED 18V V C O OSC P T T E M INDICATOR REG 18V DC FUSE LEVEL LIMITER SIREN SIREN LEVEL E M MESSAGE ROM 10 SEC DELAY MULTI CONNECTOR WIRING PIN4 PTT S W PIN2 PIN3 GND PIN1 MIC FILTER E M MESSAGE CARD OPTION E M ALL IN OSC DETECTOR BUZZER FAULT LED LOCK DIAGRAM 블럭도 FAULT CHECK NON PULSE FIRE CHECK NON PULSE ...

Страница 12: ...JEU 211AU OPERATING INSTRUCTIONS 4M OP207080 080106 EMERGENCY UNIT ...