background image

RJ12

RJ45

(Shielded)

RJ12

COAX

F-Conn.

RJ45

(Shielded)

Front View

Remote Unit

Top View

Main Unit

Содержание Testifier

Страница 1: ...User s Guide www jdsu com know Testifierf All Cable Tester...

Страница 2: ......

Страница 3: ...the F conn jack Use with test ter minator stored in back of RJ remote at bottom of tester TONE Tone genera tor Press a cable test button for the connector being used followed by the TONE button Displ...

Страница 4: ...RJ12 RJ45 Shielded RJ12 COAX F Conn RJ45 Shielded Front View Remote Unit Top View Main Unit...

Страница 5: ...TION Improperly crimped damaged or un crimped plugs can damage the jacks on the Testifier Inspect plugs for proper termination and crimping before inserting into the tester Contacts should always be r...

Страница 6: ...format Tests for shorts opens miswires reversals and split pairs Displays PASS icon for correctly wired T568A B both one to one uplink cross over cables Displays PASS icon for correctly wired 6 pin te...

Страница 7: ...gins operating in the mode for the button pressed telephone TEL coax COAX network NTWK or tone generator TONE The corresponding connectors at the top end of the tester are labeled the same as their mo...

Страница 8: ...error will flash If no connection was detected for some of the pins the first and second line of pin numbers will be blank in those pin locations If a short is detected the second line will have a in...

Страница 9: ...specific mode is selected by pressing one of the cable test buttons TEL COAX or NTWK followed by the TONE button If the Testifier was off when the TONE button is pressed the last cable test mode used...

Страница 10: ...hone cable test mode subsequent presses of the TEL button of less than 2 seconds long forces a new test cycle to begin immediately upon release of the button This is useful to immediately begin a new...

Страница 11: ...tly wired in a one to one order If all 8 pins are correctly wired with the 1 2 and 3 6 pairs crossed the Pass icon will be displayed along with a flashing Uplink icon Uplink cables are also known as c...

Страница 12: ...of the signal on the other pin of the pair yielding a nominal 10 volts peak to peak across the pair The pin number of the pin or the letters P for pin and S for shield being driven with tone and the...

Страница 13: ...present on the jacks during each test cycle If voltage is found the Volts icon is displayed and testing stops until the voltage is removed Testifierf LCD Display 1 2 3 4 5 6 7 8 8 8 8 8 8 8 8 8 8 S I...

Страница 14: ...ing To Test a Patch Cable see caution about cables with bad plugs above Plug one end of patch cable into main unit Plug other end of cable into remote unit Press TEL or NTWK as appropriate for the jac...

Страница 15: ...ger through the openings provided in the main unit and pull out of storage pocket Remove coax remote from storage pocket on backside of remote and attach to the other end of the cable to be tested Pre...

Страница 16: ...a pair will do this For coax the Tone is best applied to the shield and the shield cannot be grounded Turn on Testifier by pressing the button associated with the connector to be used followed by pre...

Страница 17: ...perly wired uplink crossover cable In Telephone mode the Rev icon will flash if all connected pins are in reverse order and the Pass icon will also be on if all 6 connections are present Telephone mod...

Страница 18: ...reverse pair is a special case of a miswire in which the pair is wired to the correct pair of pins or to another designated pair of pins but the two leads are reversed The Testifier is able to test fo...

Страница 19: ...error is the split pair error The Split icon and the pin numbers on the first and second line of the wire map with split pairs flash when there is a split pair error Testifier has the ability to turn...

Страница 20: ...2 3 not twisted with 6 3 4 5 6 7 8 OPEN MISWIRE DARK ON FLASHING LIGHT 3 4 5 6 7 8 2 S ID Open Ntwk 1 2 1 2 3 4 5 6 1 2 3 4 5 6 2 S ID Short Ntwk 7 8 Ntwk Fail 1 1 2 2 3 3 4 4 5 5 5 5 5 6 6 6 6 6 7 7...

Страница 21: ...volts To replace battery Remove the screw from the battery door on the back of the unit with a 1 Philips head screwdriver Pull battery out of cavity and remove battery snap Connect a new Alkaline 9 v...

Страница 22: ...ity 10 to 90 non condensing Battery Life 9V Alkaline battery typical times are for the full capacity of the battery used continu ously in one of the following modes Standby 2 5 years Cable Testing 150...

Страница 23: ...TP65 Replacement 1 coax remote identifier for Resi Tester or Testifier TP63 F connector jack to BNC jack adapter TP62 F connector plug to BNC jack adapter TP610 Network remote identifiers set of 8 1...

Страница 24: ...oamerPRO LanRoamer Resi Tester or Testifier with 8 remotes PC250 Nylon pouch for Resi Tester and Resi Tracer PC150 Nylon pouch for one LanScaper LanRoamerPRO LanRoamer Resi Tester or Testifier KP550 T...

Страница 25: ...t of 20 1 20 RJ11 wiremappers with 2 RJ45 to alligator cables in a nylon pouch KP314 Resi Tester cable tester Resi Tracer probe remote 1 TP309 coax remote identifier 1 TP65 12 cable assembly RJ45 to a...

Страница 26: ...pair Under Warranty Repair Calibration Services and Upgrade Services Immediate Return Authorizations Technical Assistance Expert business hour technical support is included with your product Instrumen...

Страница 27: ...ested ensuring peak performance of the complete feature set Equipment Return Instructions Please contact your regional Technical Assistance Center to get a Return or Reference Authorization to accompa...

Страница 28: ...al shipping container and material If the original container is not available the unit should be carefully packed so that it will not be damaged in transit when needed appropriate packing materials ca...

Страница 29: ...ther implied or expressed will apply nor will responsibility for operation of this device be assumed by JDSU WEEE Directive Compliance JDSU has established processes in compliance with the Waste Elect...

Страница 30: ...for appropriate disposal If the equipment was imported by a reseller whose name or logo is marked on the equipment then the owner should return the equipment directly to the reseller Instructions for...

Страница 31: ......

Страница 32: ...Document Information Doc TU9856 1 Revision 500 06 08 English www jdsu com know...

Отзывы: