Getting Started Manual – 22064010 r001 – April 2014
4 Getting Started Manual – 22064010 r001 – April 2014
5 Getting Started Manual – 22064010 r001 – April 2014
6
M
OBILE APPLICATION
The mobile application allows you to connect to a OneExpert DSL unit and control the
UI remotely, access the Job Manager, view the manual, and other functions.
Before using the OneExpert DSL with a mobile device, verify the following:
The mobile device must have the
OneExpert DSL
app installed (available on the
AppStore or from your JDSU representative).
The OneExpert DSL must have the Apple option and the Bluetooth option enabled.
To verify your options, go to the Options menu in the System Settings.
C
ONTROLLING THE USER INTERF
ACE
To control the user interface of an OneExpert DSL, the mobile device (iPad or similar)
must pair with the OneExpert DSL over Bluetooth. Then, using the OneExpert app on
the mobile device, you can connect to an OneExpert DSL and control the user interface.
P
AIRING OVER
B
LUETOOTH
On the OneExpert DSL, go to the System Settings menu, enter the Bluetooth menu,
and verify that the box next to Enabled has a check mark.
On the mobile device, verify that Bluetooth is enabled. To do this, go to the Settings
menu, and verify that Bluetooth is On.
On the mobile device or the OneExpert DSL, search or scan for devices. When you find
the device that you wish to connect to, select it. The other device will need to confirm
the pairing.
C
ONTROLLING THE USER INTERFACE
On the mobile device, launch the
OneExpert DSL
app. The Controller page appears.
Select
Device Interface
. The OneExpert DSL interface appears on the mobile device.
You can now control the instrument as if you were pressing the actual buttons on the
device. You can run most of the tests that are available on the OneExpert DSL.
Near the bottom, the Back icon appears on the left and the Tray menu icon appears on
the right. These function as if you pressed the function key on the device.
Across the bottom, icons are available for:
Controller page – the screen above, allows control of the user interface
Job Manager – used to create, edit, view, and export jobs
Quick Cards – view quick cards (short documents of instructions)
Manual – read the manual
Videos – view instructional videos
Accessories – view the OneExpert DSL accessories, including how to order
I
MPORTANT
S
AFETY
I
NSTRUCTIONS
This section contains definitions for safety terms and safety precautions you should
follow when using the OneExpert DSL.
Table 1
defines safety terms used in the product documentation. Failure to observe
these precautions while using the OneExpert DSL unit violates the intended use of this
product.
Term
Description
DANGER
Indicates an imminently hazardous situation which, if not avoided,
will result in death or serious injury.
WARNING
Indicates a potentially hazardous situation which, if not avoided,
could result in death or serious injury.
CAUTION
Indicates a potentially hazardous situation which, if not avoided,
may result in minor or moderate injury or damage to equipment.
Hazardous voltages caused by lightning strikes or accidental connection to power
circuits may be present on outdoor lines. Such lines are classified as
Telecommunications Network Voltage (TNV) lines. Telecommunications providers
employ all reasonable protective measures to limit dangerous electrical surges on TNV
lines. However, absolute protection from TNV hazards is impossible. Serious injury
could result if you do not understand the hazards of TNV, especially the hazards of
lightning strikes and accidental connection to power circuits. You must be responsible
for your own safety by employing proper safety procedures to minimize the risk of
electrical shock. Comprehensive TNV safety training is beyond the scope of this guide.
Still, you should read and understand all safety information within before using this
product. When using the product, basic safety precautions should always be followed
to reduce the risk of fire, shock, and injury to persons, including the following:
1
Read and follow all warning notices and instructions marked on the product and
included in the manual.
2
Use only the AC Adapter/Charger supplied with the product. Do not use AC Adapter/
Charger outdoors or in wet or damp locations. Connect the AC Adapter/Charger to the
correct mains voltage as indicated on the ratings label.
3
Do not allow anything to rest on the power cord, and do not locate the product where
persons can walk on the power cord.
4
Disconnect all cables from the instrument before plugging or unplugging the AC
adaptor.
5
Disconnect all cables, and power the instrument down, before removing the User
Module (e.g. Modem) or opening the battery cover.
6
CAUTION: To reduce the risk of fire, use only No. 26 AWG or larger (e.g., 24 AWG)
UL Listed or CSA Certified Telecommunication Line Cord
7
This product is intended to be used with a 3-wire grounding-type plug (a plug that has
a grounding pin). This safety feature is vital to the safe operation of the instrument. Do
not defeat the purpose of the grounding-type by modifying the plug or using an
adapter.
8
Do not use telephone equipment (other than cordless) during a lightning storm. There
is a possibility of a nearby lightning strike, which could exceed the capacity of the
telephone network protective devices and harm you.
9
Do not use this product near water for example, near a bathtub, washbowl, kitchen
sink or laundry tub, in a wet basement or near a swimming pool.
10
Do not use telephone equipment in the vicinity of a gas leak or in any explosive
environment. This tester, and most other telephone equipment, could in normal
operation generate a spark strong enough to ignite a fire or explosion.
11
Do not touch or otherwise come in contact with telephone conductors that could be
exposed to lightning or accidental connection to power circuits without first isolating
them from the telephone network.
12
Do not install telephone equipment or terminations (jacks) in wet locations unless the
equipment or termination is specifically designed for such locations.
13
Do not cause or allow telephone or telecommunication circuits to come in contact
with power circuits (mains).
14
Do not attempt to service this product yourself, as opening or removing covers may
expose you to dangerous high voltage points and other hazards. Refer all servicing
to qualified service personnel.
15
Use appropriate cables when connecting to telecommunications circuits. Putting an
RJ-11 connector in a RJ-45 port can damage the RJ-45 port.
16 WARNING:
Danger of extreme heat, fire, or explosion if battery is tampered with.
Replace only with JDSU battery (ordering number ONX580-BATTERY-
48WH). Dispose of used batteries according to the manufacturer's
instructions.
17 CAUTION:
If the equipment is used in a manner not specified by JDSU, the
protection provided by the equipment may be impaired.
18
Only trained telecommunications technicians who understand the hazards
associated with TNV lines and practice proper procedures for dealing with TNV
should use this tester.
19
Charge the lithium ion battery using only the JDSU battery charger. The battery is to
be used only with JDSU test products.
20
Be sure that TNV signals are not connected to SELV ports. If you need to access a
line that may have TNV or higher voltages present using a SELV port, you must do
so through an interface device that is certified to provide a SELV connection point.
21
Where the unit is labeled with a warning symbol, the operating manual must be
consulted to learn more about the nature of the potential hazard and any action that
must be taken.
22
Use only UL-rated cables for the test interfaces of this product.
23
The copper testing interface is classified as Measurement Category
0
. It
is not intended to be connected to circuits from Measurement categories
II
,
III
, or
IV
. The maximum voltage, including transients is 300 VDC.
24 CAUTION:
Heat Sink can become hot when the modem is in use.
Save these instructions
T
ECHNICAL ASSISTANCE
If you need assistance or have questions related to the use of this product, call or e-mail
JDSU’s Technical Assistance Center for customer support.
http://www.jdsu.com/en-us/Test-and-Measurement/services/products-and-systems-
support/Pages/default.aspx