Chapter 9
Measure Mode – Service Tab
Ethernet
230
DSAM Help User Guide
Rev. 001
15
Press
ENTER
.
16
Press the
Start
softkey.
When a ping test starts, response results begin scrolling upward in
the response box (upper right corner of the screen). The most
recent ping result is displayed at the bottom of the list.
The status box (in the lower right corner of the screen) displays
the reply statistics, including:
– Number of pings sent
– Average return time
– Number of pings lost
– Ratio of lost to sent pings
Ping data is continuously updated.
Restoring Ping Test
Defaults
To restore the default values for Packet Size and Time Between Pings.
Figure 206
Measure Mode – Ethernet Ping Test
Table 46
Ping Test Parameters
Name
Description
IP Address
Select from a list of up to ten of the most recently
used IP addresses.
Packet Size
(bytes)
Options are 64, 128, 256, 512, 1024, or 1518 (in
bytes). The default value is 64 bytes.
Time Between
Pings
Options are 0 ms, 10 ms, 25 ms, 50 ms, 100 ms, 1
sec, 2 sec, or 5 sec. The default value is 1 second.
21128026 R001 DSAM Help User Guide.book Page 230 Thursday, February 5, 2009 2:02 PM
Содержание DSAM-1500
Страница 2: ...21128026 R001 DSAM Help User Guide book Page ii Thursday February 5 2009 2 02 PM ...
Страница 4: ...21128026 R001 DSAM Help User Guide book Page iv Thursday February 5 2009 2 02 PM ...
Страница 361: ...21128026 R001 DSAM Help User Guide book Page 321 Thursday February 5 2009 2 02 PM ...