Appendix A
Test Results Definitions
FT1 results
CT-650 Command-Line Reference Guide
Release 9.4
145
FT1 results
The following sections describe the fields appearing under various
FT1 test results screens.
Header
The following fields appear in the header of the FT1 test results
screens.
Test Length
Length of test for a timed test, in hours and minutes.
Field
Description
Field
Description
Test
Test name.
N/A
appears for selftests.
DG
Digroup being tested.
UNKNOWN
appears if the digroup
cannot be identified.
N/A
appears for a selftest.
SIG SRC
Signal source for the tested circuit. Possible values
are as follows:
–
INT
or
INTERNAL
indicates the signal comes from
the backplane from another card.
–
EXT
or
EXTERNAL
indicates the signal comes from
the DCS or a direct connection.
–
M13
or
EXTERNAL (M13 MUX)
indicates the sig-
nal comes from the DS3 Demux/Shelf Controller
Card or from an M13 card configured for the
CT-650.
–
RCVD T3
is the only source that indicates the DS3
signal is not being dropped from a higher rate.
During a selftest, the
RCVD T3
signal is an inter-
nally generated DS3 signal from the RTU.
Содержание CT-650
Страница 1: ...CT 650 Wideband Test Unit Release 9 4 Command Line Reference Guide ...
Страница 2: ......
Страница 3: ...CT 650 Wideband Test Unit Release 9 4 Command Line Reference Guide ...
Страница 4: ......
Страница 22: ...Contents xxii CT 650 Command Line Reference Guide Release 9 4 ...
Страница 104: ...Chapter 7 DS0 VF Test Commands Description of VF test commands 78 CT 650 Command Line Reference Guide Release 9 4 ...
Страница 108: ...Chapter 8 Batch Files Unavailable commands for batch files 82 CT 650 Command Line Reference Guide Release 9 4 ...
Страница 198: ...Appendix A Test Results Definitions Loopback status information 172 CT 650 Command Line Reference Guide Release 9 4 ...
Страница 240: ...Appendix D Customer Services and Support Training options 214 CT 650 User s Guide Release 9 3 ...
Страница 247: ......