JD-MEDIA ZA-1120A Скачать руководство пользователя страница 5

AMP SECTION

AUTOMATIC VARIABLE SPEED FAN
OVER CURRENT PROTECTION
OVER HEATING PROTECTION
LOAD SHORT CIRCUIT PROTECTION
BUILT IN L.P.F(LOW PASS FILTER) CIRCUIT
OUTPUT LED INDICATOR
5 ZONE SPEAKER OUTPUT OR ALL CALL
SPEAKER ATTENUTOR PER CHANNEL BY 6 STEP

AMP 부분 

F

EATURES (

특징)

PRE AMP AND OTHER

INPUT GAIN VOLUME CONTROL PER MICROPHONE
SELECTIVE PHANTOM POWER PER MICROPHONE INPUT
DIN CONNECTER FOR P.T.T(PUSH TO TALK) MICROPHONE INPUT
RCA JACK FOR LINE 4, 5 INPUT
RCA JACK FOR RECORDING OUTPUT
CONNECT FOR PRE-OUT/EXTERNAL AMP IN
EQUALIZER PER INPUT CHANNEL
TELEPHONE PAGING AND NIGHT RINGER
CHIME
SIREN
OPTIONAL MODULE CONNECTION
(TP-100, DM-100, CDP-100, CDR-100)
REMOTE CONTROL FOR POWER ON/OFF
SOFT START FOR BATTERY POWER SUPPLY DELAY
REMOTE CONTROL SYSTEM BY RJ45 CONNECTER
1. DIGITAL MESSAGE
2. CHIME
3. CONNECTION WITH 3MODULES(RC-100) SIMULTANEOUSLY
AUTO ALERT ANNOUNCEMENT AND AUTO POWER "ON"
CONNECTING TO DIGITAL MESSAGE(DM-100)
(MESSAGE FIRST PRIORITY CONNECTING  WITH FIRE 
ALARM SYSTEM)
MIC 1, 2, 3 PRIORITY SELECTOR SWITCH 

PRE AMP및 기타부문

3

자동 속도조절 팬 내장.
과전류 보호회로 채택.
스피커 선로 쇼트 검출회로 채택.
L.P.F 회로 내장.
출력지시 LED LEVEL 메터.
5-ZONE SPEAKER OUTPUT 또는 SPEAKER ALL CALL기능.
ZONE별 스피커 출력 조정가능. 

각 MIC입력 GAIN 볼륨 채택.
각 MIC 입력별 PHANTOM POWER 공급가능.
PUSH TO TALK(P.T.T) MIC 입력을 위한 별도의DIN 콘넥터 채택.
LINE 4, 5입력 RCA JACK 채택.
녹음출력 RCA JACK 채택.
PRE OUT/외부 AMP IN 콘넥터 채택.
각 입력별 이퀄라이져 콘트롤 채택.
TELEPHONE PAGING및 NIGHT RINGER 기능채택.
CHIME 기능채택. 
SIREN 기능채택.
TP-100, DM-100, CDP-100, CDR-100 
PACK 연결 가능.(OPTION)
전원공급 원격제어 기능.(교류/직류)
배터리 전원공급시 DELAT가능.
원격제어 시스템 (RJ45 콘넥터)
1. DEGITAL MESSAGE 원격제어.
2. CHIME 원격제어
3. REMOTE CONTROLLER(RC-100) 3개 연결 운용가능.
DEGITAL MESSAGE(DM-100)연결시 자동전원공급 및 자동 경고 
방송.(MESSAGE FIRST PRIORITY가 화재경보 시스템과 연결된 상태 
에서 가능)
MIC 1, 2, 3 우선권 선택 스위치. 

1. MIC/LINE LEVEL

1. MIC/LINE LEVEL

P.T.T 볼륨/EQ 볼륨
입력1의 레벨과 P.T.T REMOTE(PTT-100)의 레벨을 조정할 수 있
으며, BASS와 TREBLE은 설치 장소의 특성을 고려하여 설치 장소에 
맞도록 음질을 조정하십시오. 통상 조정 위치는 마스터 볼륨이 2시 
방향일 경우 ⑦번의 출력 레벨메터 "0" 위치의 LED가 켜지도록 조정
하십시오.

P.T.T1 VOLUME/EQ VOLUME
P.T.T1 volume control/EQ volume control let you adjust input 1
level and P.T.T remote(PTT-100)level. BASS and TREBLE 
CONTROLS make you adjusted equalizer so as to suit for 
surrounding usually, first, position adjusted should be set at "0"
of LED indicator with two 0'clock of MASTER volume.
Secound, you can increase input volume to the position "0" of
LED indicator.
IMPORTANT NOTE :
1. In case the priority function is activated, if you supply signal
    to MIC/LINE 1, than, all signals including LINE 4,5 PAGING
    RINGER and module signals like TP-100, CDP-100, CDR-100
    will be closed.
    (set switch of SW305 on the FRONT PCB to "SLAVE").
 

F

RONT PANEL CONTROLS 

(전면기능)

MIC / LINE LEVEL

1

P.T.T

BASS

TREBLE

2

REMOTE

BASS

TREBLE

3

BASS

TREBLE

4

BASS

TREBLE

5

BASS

TREBLE

LINE LEVEL

1

6

2

5

3

4

SPK ZONES & AT

OUTPUT LEVEL

T.

CLIP

0

3

8

13

CHIME

0

10

LEVEL

TEL

RINGER

LEAK

10

PAGING

10

ON

SIREN

0

10

LEVEL

OFF

LEAK

POWER

MASTER

AC

DC

PROT

ALL CALL

5

4

3

2

1

0

10

0

10

0

10

0

10

0

10

0

10

1

6

2

5

3

4

1

6

2

5

3

4

1

6

2

5

3

4

1

6

2

5

3

4

TEMP

STAND-

BY

ATT. ZONE  AMPLIFIER

ZA-1240A

7

8

1

2

3

4

6

5

중요사항
1. MIC/LINE1 신호가 입력되면 PRIORITY가 동작되어 LINE 4, 5
    PAGING RINGER 또는 PACK류의 TP-100, CDP-100, CDR-100
    (전면 PCB SW305 스위치를 SLAVE로 선택)의 신호가 차단됩니다.
   

Содержание ZA-1120A

Страница 1: ...ATT ZONE AMPLIFIER ZA 1120A ZA 1240A WWW JD MEDIA CO KR JD MEDIA...

Страница 2: ...P 0 3 8 13 CHIME 0 10 LEVEL TEL RINGER LEAK 10 PAGING 10 ON SIREN 0 10 LEVEL OFF LEAK POWER MASTER AC DC TEMP 0 10 0 10 0 10 0 10 0 10 0 10 1 6 2 5 3 4 1 6 2 5 3 4 1 6 2 5 3 4 1 6 2 5 3 4 PROT ATT ZON...

Страница 3: ...Keep in mind the following when connecting the apparatus Connect the apparatus after reading of O P manuals Connect each connection of amplifier perfectly if not it maybe Caused hum damage electric s...

Страница 4: ...cabinet IMPORTANT Be sure rear of amplifier is securely mounted to rack AMPLIFIER TOP VIEW 4in 10cm MIN RACK CABINET 2 4in 6cm MIN RACK MOUNT SPACE AIR FLOW IN RACK CABINET AIR FLOW EQUIPMENT RACK SID...

Страница 5: ...EN TP 100 DM 100 CDP 100 CDR 100 PACK OPTION DELAT RJ45 1 DEGITAL MESSAGE 2 CHIME 3 REMOTE CONTROLLER RC 100 3 DEGITAL MESSAGE DM 100 MESSAGE FIRST PRIORITY MIC 1 2 3 1 MIC LINE LEVEL 1 MIC LINE LEVEL...

Страница 6: ...g is activated priority makes stopping all signal like LINE 4 5 CHIME SIREN and signal of modules against paging set switch of SW305 on the FRONT PCB to SLAVE If priority is not activated against MIC...

Страница 7: ...alanced jack The stereo signal of the connected sound sources gets internally converted into a manual signal All signals can be recorded but recording out can not be adjusted by master volume because...

Страница 8: ...ration of data of data receipt data LED indicator will be turn ON DATA LED INDICATOR SLAVE SELECTOR All signal output of remote controller RC 100 will be closed under setting on of priority switch on...

Страница 9: ...signal priority S W SW305 SLAVE Rear panel No MIC PRIORITY S W OFF Pack signal priority S W SW305 SLAVE Pack signal priority S W SW305 PRIORITY Rear panel No remote receiver RR 100 side S W SLAVE Sid...

Страница 10: ...roller RC 100 SECRETARY SUPER INTENDENT 24VDC BATTERY MANUFACTURING AREA OR SHOP CD PLAYER 6CD 100 LINE 4 INPUT LINE 5 INPUT ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 REC LEVEL EXEC 0 10 H P MIC LINE IN CLIP...

Страница 11: ...0 50 PHANTOM POWER 3 GAIN DC POWER PHANTOM POWER 2 PHANTOM POWER 1 P T T REMOTE MIC PRIORITY AUDIO IN CHIME PRIORITY G PRIORITY SLAVE INPUT DATA LOW IMP 4 3 2 1 5 NIGHT RINGER HOT COLD PAGING IN TEL M...

Страница 12: ...ITY ATT OUTPUTS SPK ZONES AC IN 50 60Hz DO N P A REC LINE IN 5 4 0dB L R REMOTE 300W AM GND FM 75W POWER L R 4 SERIAL NO WARNING TO REDU OR ELECTRIC SHOCK D EQUIPMENT TO RAIN OR EACH ZONE 50W MAX MAX...

Страница 13: ...ES DM 100 ON DM 100 OFF 7 DM 100 ON OFF RJ45 4 PAIRS LAN CABLE 100m 9 OUT LINK 10 AUX INPUT 11 AUDIO OUT GAIN RC 100 2 1 PRIORITY SLAVE SLAVE RC 100 PRIORITY RC 100 TALK S W SLAVE RC 100 PRIORITY RC 1...

Страница 14: ...AL SIGNAL TO NOISE RATIO T H D POWER CONSUMPTION 1 8 POWER CURRENT DRAW 120V 230V 1 3 POWER CURRENT DRAW 120V 230V RATED POWER CURRENT DRAW 120V 230V GENERAL POWER SOURCE OPTION DIMENSIONS mm inches W...

Страница 15: ...PHANTOM POWER GAIN 50 10dB CHIME R M 1 2 3 MIC PROT 24V MESSAGE FIRST PROT CHIME P T T REMOTE SLAVE REMOTE PRIORITY ATT ALL CALL M6 M5 M4 M3 M2 M1 REPEAT STOP START STOP COM G BUSY DRIVER SERIAL TO PA...

Страница 16: ...ZA 1120A 1240A OPERATING INSTRUCTIONS ATT ZONE AMPLIFIER...

Отзывы: