background image

This unit is not intended for use in explosion hazardous
areas or with explosives or flammable gases and must
not be operated under these conditions.

If these warning notices are ignored possible serious in-
juries and/or damages may be caused.

Only qualified staff who have been trained according to
this manual should operate and maintain this instrument.

For certain and safe operation the instrument needs to
be transported carefully, be part of a well planned appli-
cation, installed correctly as well as operated and main-
tained according to these instructions.

Requirements of qualifications of staff:
Qualified staff in the sense of this manual and/or the war-
ning references are persons, who are familiar with setup,
mounting,  start-up  and  operating  of  this  product  and
have sufficient qualification.

Start up

7.

1.

check of the proper installation.

2.

Review the equipment for damage.

3.

check whole back purge supply line to gas sam-
pling probe for leaks.for leaks.

4.

Open cabinet door.

5.

choose timing intervals according table:

CAUTION

!

Selection wire is operated with line voltage. Shut down
power supply before manipulating the interval selection
circuit.

6.

Switch unit on or supply power.

Manual JES-301k

Dieses Gerät darf nicht in explosionsgefährdeten Berei-
chen  oder  mit  zündfähigen  und  leicht  entflammbaren
Gasen betrieben werden.

Bei Nichtbeachtung der Warnhinweise können schwere
Personenschäden und/oder Sachschäden auftreten.
Nur entsprechend qualifiziertes und geschultes Perso-
nal, welches mit allen Warnungen und Instandhaltungs-
maßnahmen gemäß dieser Betriebsanleitung vertraut
ist, darf an diesem Gerät oder in dessen Nähe arbeiten.
Der einwandfreie und sichere Betrieb dieses Gerätes
setzt sachgemäßen Transport, fachgerechte Lagerung,
Aufstellung und Montage sowie sorgfältige Bedienung
und Instandhaltung voraus.

Anforderungen an die Qualifikation des Personals:
Qualifiziertes Personal im Sinne dieser Betriebsanlei-
tung bzw. der Warnhinweise sind Personen, die mit Auf-
stellung, Montage, Inbetriebsetzung und Betrieb dieses
Produktes vertraut sind und die über eine ihrer Tätigkeit
entsprechenden Qualifikation verfügen.

Inbetriebnahme

7.

1.      kontrolle der vorschriftsgemäßen Installation
2.      Überprüfung des Gerätes auf Beschädigung
3.      Dichtheitsprüfung für die gesamte Verschlauchung

zwischen Steuergerät und Messgassonde durch-
führen

4.      Gehäusetüre öffnen.

5.      Rückspül-Intervall nach folgender Tabelle einstel-

len:

ACHTUNG

!

Der Auswahldraht steht unter Netzspannung. Vor dem
Einstellen des Rückspülintervalls unbedingt Gerät vom
Netz nehmen. 

6.       Netzanschluss herstellen.

BA_DE_JES-301k_v2.1 

–––––––––––––––––––––––––– [ 9 ] ––––––––––––––––––––––––––

PLC Input

Intervall

I1

2 Stunden

I2

4 Stunden

I3

8 Stunden

I4

12 Stunden

I5

24 Stunden

PLC Input

Interval

I1

2 hours

I2

4 hours

I3

8 hours

I4

12 hours

I5

24 hours

Содержание JES-301K

Страница 1: ...JCT ANALySENTEchNIk GMBh BEDIENUNGSANLEITUNG OPERATING MANUAL 12 15 JES 301K...

Страница 2: ...ng manual as is without any warranty of any kind either express or implied including warranties or conditions of merchantability or fitness for a particular purpose Subject to technical modifications...

Страница 3: ...JcT Analysentechnik Gmbh haftet nicht bei eigen m chtigen nderungen des Ger tes oder f r deren un sachgem e handhabung oder Verwendung Wenn anzunehmen ist dass ein gefahrloser Betrieb des Ger tes nic...

Страница 4: ...n Verh ltnis sen nach schweren Transportbeanspruchungen Besondere Bestimmungen 1 3 Die Steuerger te f r R cksp lung sind nur f r den Ein satz in Gasanalysensystemen bestimmt Beachten Sie die Angaben i...

Страница 5: ...l fuse pro tection external on installation site Protection class IP 56 EN 60529 Status relay volt free contact Switching capacity relay max 250 VAc 5 A min 12 VDc 2 5 mA connection status relay screw...

Страница 6: ...1 248 x 79 x 95 mm B x h x T k1039026 Druckluftspeicher aus Edelstahl Volumen 2 l An schl sse 2 x G1 300 x 134 x 54 mm B x h x T k1039023 Druckluftspeicher aus Edelstahl Volumen 5 l An schl sse 2 x G1...

Страница 7: ...zu trennen Das Ger t muss entsprechend den rtlich geltenden Vorschriften angeschlossen und geerdet werden Die relative Feuchtigkeit kann bis zu 95 RF betra gen solange kondensation vermieden wird Es i...

Страница 8: ...or during storage periods Disconnect power before repair or maintenance Manual JES 301k tive Lasten sind mit entsprechenden Schutzma nahmen anzuschlie en z B Freilaufdioden bei in duktive Lasten und S...

Страница 9: ...ndf higen und leicht entflammbaren Gasen betrieben werden Bei Nichtbeachtung der Warnhinweise k nnen schwere Personensch den und oder Sachsch den auftreten Nur entsprechend qualifiziertes und geschul...

Страница 10: ...se zur ck bleiben Das ist normal und beeintr chtigt die Funktion der Entnahmesonde nicht NOTE After power supply the unit performs immediately one complete back purge cycle NOTE The status contact is...

Страница 11: ...f its service life Dimensions 9 Manual JES 301k Beenden des Betriebs 8 1 Netzanschluss l sen 2 Luftzufuhr schlie en HINWEIS Ist es zu Wartungs oder Reparaturzwecken notwendig das Ger t an JcT Analysen...

Страница 12: ...g Str 4 A 2700 Wr Neustadt Tel 43 0 2622 87 201 Fax 43 0 2622 87 2011 sales jct at Firmenbuchgericht kreisgericht Wr Neustadt FN 119682 d UID Nummer ATU 20559900 12 Manual JES 301k BA_DE_JES 301k_v2 0...

Отзывы: