User Cautions
Careful measures are taken in the design of this
product to ensure its quality; however, the follow-
ing cautions should be read and understood by all
users in order to confirm safe operation.
Installation Cautions
The Installation Cautions are defined as follows:
1. Do not allow the Unit to endure or operate at a
high temperature, in high humidity and/or in a
dusty environment.
2. Do not install the Unit into an area where exces-
sive vibration or shock are present.
3. The Unit is not designed for outside installation.
Be sure that the Host Machine contains enough
protection to avoid wet or dusty conditions when
installing in either an indoor or open-air space.
4. Avoid exposing the Unit to direct Sunlight and/or
Incandescent Lamp illumination having a
Gradient Angle of 15 Degree or more, and an
illumination index of 3000 Lux or less.
5. Ensure that the Host Machine is designed for
daily operational access for maintenance and/or
clearing a Banknote jam (refer to “Unit Dimen-
6. When
installing
the
equipment, connect the
Frame Housing to the Frame Ground of the Host
Machine.
7. If an unused Interface Harness exists, cut the
Harness off short to avoid attracting static elec-
tricity or a short circuit possibility that may cause
damage to the Unit.
8. Because this equipment is a component product,
close the Host Machine’s door before using it.
9. Do not operate the
RT/RQ Unit without the Cash
Box and/or the Recycler or while the Cash Box
and/or the Recycler’s door is open.
10. This Unit is designed to use a Limited Power
Source. Be sure that the Host Machine’s cabinet
material design meets local safety standards.
11. Do not use the Unit where it may be exposed to
airborne evaporated or sporadic chemicals and/or
oil.
12. Ensure that the Host Machine is designed consid-
ering the risk of electronic components that can
cause induced noise. The noise generated by the
components on the Host Machine may affect and
degrade the Validation performance.
Mounting, Dismounting & Transportation
Methods for Mounting, Dismounting, and Trans-
porting the Unit are as follows:
1. Be sure to remove the Power from the RT/RQ
Unit before attaching or unplugging Connector
Plugs to avoid the risk of damage to the Unit.
2. Be sure to carry the Unit by both hands when
transporting it. Holding the Unit by one hand
may cause personal injury if the Unit accidentally
becomes disassembled and falls away from the
Frame housing.
3. Be careful not to use excessive outside pressure
on the Recycler, or subject it to excessive vibra-
tion during transportation.
4. Check that the UBA Pro Unit does not drop off
the Unit Frame while pulling the Recycler for-
ward from the Frame.
Operation Cautions
The Operation Cautions are defined as follows:
1. When closing the UBA Pro Unit, ensure it firmly
clicks into place.
2. When installing the Recycler, ensure it firmly
clicks into place.
3. Do not remove the Recycler and/or the Cash Box
during operation.
4. Do not throw or pound hard on the Recycler.
5. Be sure to follow the specified measures when
removing or re-seating any removal unit of the
RT/RQ Unit. Improper handling may cause per-
sonal injury and/or damage to the equipment.
6. The Recycler is not protected by a key. Caution is
advised for cash handling.
Preventive Maintenance
The Preventive Maintenance requirements are
defined as follows:
1. Be sure to remove the Power from the RT/RQ
Unit before beginning a maintenance procedure,
except for the Recycler and the Cash Box. The
equipment produces improper operating signals
while in maintenance mode that may cause per-
sonal injury.
2. If the Transport Path and/or Sensors are dirty due
to dust, foreign objects or other such debris
adhering to it, the Banknote acceptance rate will
degrade. Clean the Unit once a month to keep its
performance optimal.
3. Use a soft, lint-free cloth, cotton swab or a com-
pressed air spray to clean dust and debris from
the Banknote path and the inside areas of the
Recycler.
4. Do not redesign or disassemble the Recycler.
Unauthorized use by inadequately-trained
personnel, or use outside the original manufac-
turer’s intent for operation voids the warranty.
Caution: DO NOT use any alcohol,
solvents, abrasive cleaning agents,
or citrus-based cleaners that can
damage the plastic surface of the
device when cleaning it.
WARNING: This Unit is designed
for use with a Limited Power
Source! Design the Host Cabinet
space to meet all local related
safety standards.
Caution: Make Interface Harness
connections to the Host Machine
shorter than 9.84 Feet (3 Meters) in
length. Cut off all unused portions
of the Interface Harness wiring to
avoid static electrical effects or
short circuit possibilities that
could cause damage to the Unit.
Содержание UBA Pro RQ Series
Страница 6: ...P N 960 000209R_Rev A 2019 JAPAN CASH MACHINE CO LTD iv THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 10: ...P N 960 000209R_Rev A 2019 JAPAN CASH MACHINE CO LTD viii THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 57: ...UBA Pro RT RQ Series Banknote Recycler P N 960 000209R_Rev A 2019 JAPAN CASH MACHINE CO LTD...