background image

RS3 SYSTEM 

jcm

technologies

 

 

1.

 

Introduction  

1.1 General description  

RadioSens3  system  is  designed  for  Fast  doors  and  Flat-slat  rolling  shutters  in  an  Industrial,  Commercial  or 

Residential environment. RadioSens3 is an impact detection system installed at the principal edge of the door. It 

works detecting any obstacle before the strength exceeds regulations limits and then inverting door movement. 

RadioSens3 is a wireless system based on an RF transmitter and a receiver card plugged in the control panel 

which permanently monitors the status of the transmitter programmed. 

The  RadioSens3  system  (RS3  T868,  RS3  TGL868  and  RSEC3)  complies  with  the  EN  ISO  13849-1:2015 

standard, category 2, PLd. Certified by TÜV NORD CERT GmbH. 

 

 

 

 

 

 

 

 

 

 

 

 

 

MINIMUM REQUIREMENTS: 

- Minimum speed at any point of the door: 0,1m/s 

- Door Maximum width: 4 meters 

- Maximum tolerance in door repetitive movements: 5% 

- Minimum distance between the last 2 slats: 2mm 

- RS3 installation in the central part of the door 

 

Содержание RS3 TGL868NF

Страница 1: ...jcmtechnologies RS3 TGL868NF RadioSens 3 System EN User manual RADIOSENS 3...

Страница 2: ...tallation 7 3 Operation 10 4 Programming 11 4 1 Memorizing transmitter into receiver 11 4 2 System programming 12 5 Checking and maintenance 13 5 1 Troubleshooting 13 5 2 Replacing transmitter battery...

Страница 3: ...device must be provided This system must only be installed by qualified persons with experience in automatic doors gates installations and with knowledge of the applicable EU standards The instruction...

Страница 4: ...ing door movement RadioSens3 is a wireless system based on an RF transmitter and a receiver card plugged in the control panel which permanently monitors the status of the transmitter programmed The Ra...

Страница 5: ...cmtechnologies 5 Typical installation shown in the figure below A RadioSens3 transmitter set at the last slat of a roller door aluminium and connected via radio to RSEC3 receiver with a VERSUS control...

Страница 6: ...RS3 SYSTEM jcmtechnologies 6 Options and sensibility selectors must be set before programming Any later change will have no effect...

Страница 7: ...inimum 2mm of movement Avoid placing metallic surfaces between the receiver and the transmitter It is recommended to use limit switches in the installation and to have them properly connected or to as...

Страница 8: ...st slat Avoid placing metallic surfaces between the receiver and the transmitter First place the visor on the surface of the door to use it as template to make the holes in the door Then place the bot...

Страница 9: ...of movement The slat where the RS3 is fixed should stay in a perfect vertical position while the shutter is on the opened position The settings of the upper limit switch of the motor should not allow...

Страница 10: ...e conditions of use The closing movement must start with the door fully open It is not allowed to close the door from intermediate points If the door is half open only the opening movement is allowed...

Страница 11: ...ter into receiver Receiver only keeps one RadioSens3 transmitter in memory at the same time This is stored always as security on closing PRESS PROG PUSHBUTTON LED TURNS ON PRESS TRANSMITTER PROG ONE B...

Страница 12: ...mming of the control panel with the security element stored See programming section on control panel user s manual If you change the position of RadioSens3 transmitter you must perform the system prog...

Страница 13: ...ure of RS3 transmitter in open door status Reprogram the manoeuvre until no calibration failure RS3 transmitter ON OFF Indicates that the door is passing through the inhibition zones It is only indica...

Страница 14: ...installed in Fast doors and Flat slat rolling shutters Other applications than specified are not guaranteed Manufacturer reserves the right to change the equipment specification without prior warning...

Страница 15: ...able RS3 Frequency Multifrequency system auto adjustable 868 MHz Standby Operating consumption 0 1 mA 12 mA Radiated power 1 mW Range in open field 50 m Operating temperature 20 C to 55 C Watertighnes...

Страница 16: ...h the relevant fundamental requirements of the RED Directive 2014 53 EU as well as with the Machine Directive 2006 42 EC whenever its usage is foreseen and with the 2011 65 EU RoHS Directive See websi...