1248015-GB_v1.1
ROLLER 868
5
B2) Semi-automatic operating in opening and dead man operating in closing:
Optionally two pushbuttons could be connected. One on the ALT terminal that will
operate as an opening/stop button in opening, and the other on the BSEG terminal that
will operate as a dead man button in closing.
In case of using a safety edge in opening, it is necessary to remove the J1 jumper.
If safety edges are not used, situate the J1 jumper on 1B.
(3)
(3)
(1)
8k2
(3)
(3)
To operate in dead man by radio is possible with the wireless devices for dead man operation.
TIME PROGRAMMING
The door must be completely closed before starting time programming.
Press the PROG/RESET button for 1 second to enter programming. The red PROG pilot light
will come on and the equipment will emit an acoustic signal. Use the ALT/START button to
programme the run.
(Optional)
(1) - Safety edge in opening
(2) - Safety edge in closing
(3) - NO pushbutton
(4) - NC security contact