1248015-GB_v1.1
ROLLER 868
3
Possible connections:
A1) Connection of two safety edge in parallel (open and close):
This acts on opening and
closing, causing stoppage and 1 second inversion. The connection of a start button is
optional. J1 in OFF.
(3)
(1)
(2)
(4)
8k2
8k2
A security device (photocells, normally closed contact) can be connected in series with
the safety edge. The activation of this security device causes a stoppage and a total
reversion of the door.
A2) Connection of a safety edge (open or close):
This acts on opening and closing,
causing stoppage and 1 second inversion. The connection of a start button is optional.
Situate the jumper J1 on 1B position.
(4)
(1) / (2)
8k2
(3)
(Optional)
(1) - Safety edge in opening
(2) - Safety edge in closing
(3) - NO pushbutton
(4) - NC security contact
(Optional)
(1) - Safety edge in opening
(2) - Safety edge in closing
(3) - NO pushbutton
(4) - NC security contact