P/N 960-100929R_Rev. 7 {EDP #148849}
© 2017, JAPAN CASH MACHINE CO., LTD.
6 - 1 3
Calibration and Testing
iVIZION® SeriesNext-Generation Banknote Acceptor Unit
Section 6
LED Indicator Test
Perform the following steps to test the LED Indica-
tors.
1. Launch
the
“
Test Item Select
” Screen again
(Refer to “PC Performance Test Preparation” on
page 6-11 of this Section).
2. Click on the “
Display Test
e
).
3. Click on the “
Start
a
)
to begin the LED Indicator Test.
4. Check the Status LED’s condition. When the
Status LED Indicator blinks in a
Red
,
Green
, and
Blue
Color sequence, the Status LED is perform-
ing normally.
5. Click on the “
Stop
” Screen Button (Figure 6-56
b
)
to end the LED Indicator Test.
6. Click on the “
Exit
c
)
to return to the “
Test Item Select
” Screen.
Sensor ON/OFF Test
Perform the following steps to enable the Sensor
ON/OFF Test.
1. Launch
the
“
Test Item Select
” Screen again
(Refer to “PC Performance Test Preparation” on
page 6-11 of this Section).
2. Click on the “
Sensor ON/OFF Test
” Screen But-
ton (Figure 6-53
f
).
3. Click on the “
Start
a
)
to begin the Sensor ON/OFF Test. The current
testing condition is indicated in a column adjacent
to the Function being tested on the Figure 6-57
Screen.
Five (5) actions are required to check all twelve
(12) Sensors in the iVIZION Unit. Refer to Table
6-4 for each action regarding the related Sensor
being tested.
When the desired test action is complete, the
resulting condition of each Sensor is indicated by
its Screen condition turning “
ON
”.
4. Click on the “
Stop
” Screen Button (Figure 6-57
b
)
to end the Sensor ON/OFF Test.
5. Click on the “
Exit
” Screen Button (Figure 6-57
c
)
to return to the “
Test Item Select
” Screen.
Figure 6-56
Figure 6-56
LED Indicator Test Screen
a
b
c
Figure 6-57
Figure 6-57
Sensor ON/OFF Test Screen
a
b
c
Table 6-4
Sensor Actions and Conditions
Action
Sensor
Condition
Open the Acceptor Unit’s
Upper Guide
Entrance
OFF
→
ON
CIS L2
CIS L1
CIS R1
CIS R2
Exit
Open the Transport Unit’s Upper
Guide
Feed-In
OFF
→
ON
Feed-Out
No Action Required (Seat the
Cash Box correctly in place)
Cash Box
(Large Cash Box or
Standard Cash Box)
OFF
→
ON
Remove the Cash Box
from the Unit
Nearly Full
OFF
→
ON
Hold-down the Pusher Plate and
slide a 80x50mm piece of
Cardboard in-between the Frame
Outer LR and the Pusher Plate
*
*. Review Figure 6-36 and Figure 6-37 on page 6-8 regarding how to set
the Cardboard in place.
Home Position
OFF
→
ON