![JCM ivizion ld Скачать руководство пользователя страница 84](http://html1.mh-extra.com/html/jcm/ivizion-ld/ivizion-ld_operation-and-maintenance_3544215084.webp)
P/N 960-100929R_Rev. 7 {EDP #148849}
© 2017, JAPAN CASH MACHINE CO., LTD.
6 - 1 2
Section 6
iVIZION® SeriesNext-Generation Banknote Acceptor Unit
Calibration and Testing
9. Click on each Screen Button to begin its related
Performance Test. A Screen similar the Screen
shown in Figure 6-54 will appear for each Test.
For more detail concerning each Performance
Test, “Performance Test Items using a PC” on
page 6-11 of this Section.
10. Click on the related “
Start
a
) to begin the desired Performance Test.
When the desired Performance Test is complete,
click on the “
Stop
b
).
If a return to the “
Test Item Select
” Screen is
desired, click on the “
Exit
” Screen Button (Figure
c
).
Performance Test Procedures
This portion provides information concerning each
Performance Test Procedure.
Any Motor Test
Perform the following steps to test the Transport
Motor’s Normal Rotation, the Transport Motor’s
Reverse Rotation, the Stacker Motor’s operation
and a complete Cyclic Movement Test.
The following four (4) Motor Tests available:
•
Transport Motor Normal Rotation Test
•
Transport Motor Reverse Rotation Test
•
Stacker Motor Test
•
Cyclic Movement Test.
To run a specific Test, proceed as follows:
1. Launch
the
“
Test Item Select
” Screen (Refer to
the “PC Performance Test Preparation” on
page 6-11 of this Section).
2. Click on the desired Test Screen Button from the
Menu Screen provided (Refer back to Figure 6-53
a, b, c
&
d
).
3. Click on the “
Start
” Screen Button (Refer to Fig-
a
) to begin each Test.
4. Check that the Status LED is blinking at a
Yellow
Color rate. (Table 6-3 to identify the
various Status LED conditions).
5. Click on the “
Stop
” Screen Button (Figure 6-55
b
)
to end each Test.
6. Click on the “
Exit
” Screen Button (Figure 6-55
c
)
to return to the “
Test Item Select
” Screen.
Table 6-3 lists the Status LED indications for each
normal or abnormal Test Item condition.
Figure 6-54
Figure 6-54
Start, Stop & Exit Screen Button
c
b
Table 6-3
LED Indications for each condition
Test Item
Screen Button
Status LED
Normal
Abnormal
Transport Motor
Normal Rotation
Transport motor
Forward
Yellow
Flashes
Lit Yellow or
Extinguished
(Out)
Transport Motor
Reverse Rotation
Transport motor
Reverse
Stacker Motor
Stacker motor
Forward
Cyclic Movement
*
*. Once the Cycle Movement Test is complete, transport movement will
halt for approximately 25 seconds; then start the test again.
(See “Error, Jam and Reject Code Tables” on page A-2 of Appendix
A in this Service Manual when the Status LED indicates an abnormal
operating condition).
Cycle Test
Red Flashes
Figure 6-55
Transport Motor Normal Forward
Figure 6-55
Transport Motor Normal Forward
Test Screen
a
b
c