ERRORS

Display 

Type of error

ERROR 1 

Incorrect password

ERROR 2 

Code not found or memory position free 

ERROR 3 

Repeated code: shows the memory position of the programmed code.  A sound signal is issued. 

ERROR 4 

Position occupied: jumps to the first free position. A sound signal is issued. 

ERROR 5 

Data outside range 

ERROR 6 

Lack of space available in memory for the range selected or memory full.  A sound signal is issued. 

ERROR 7 

Memory error: memory card not inserted, erroneous or with incorrect format (from other equipment). 

ERROR 8 

Events error: events card incorrect or with incorrect format (from other equipment).

OPTIONAL ANTI-PASSBACK CARD OPERATIONS 

Card connections

Connect the anti-passback card to the controller, disconnecting the power supply.

5

1

2

3

4

1

2

3

4

5

Detection indication Leds

EXIT presence contact

ENTRY presence contact

Common

Connect card to controller

Operations

The Anti-passback provides access and exit control, preventing a user from accessing consecutively in the same direction.  The user 
must access only once in each direction (entry and exit).

The Anti-timeback is a timed anti-passback and allows for access twice consecutively in the same direction after the selected time. 

Operations with transmitters

Magnetic sensors must be used for card operations with transmitters to be able to distinguish the entry and exit of vehicles to and 
from an installation. Therefore, the card includes three terminals (presence contact normally open for entry and exit and common) 
for the connection of sensors. 

Warning:

 to validate entry access, one must be located on the entry loop and press the transmitter at the same time. To validate 

exit access, one must be located on the exit loop and press the transmitter at the same time.

Operations with access control devices

In this case, magnetic sensor connection is optional (where not used, leave the terminals unconnected). 

Modes

If you work at MODE 1, the configuration will be the following: channel 1 for entry, channel 2 for exit. The channels 3 and 4 will be 
free and they will not be controlled by the anti-passback.
If you work at MODE 2, the configuration will be the following: channel 1 et 3 for entry, channel 2 et 4 for exit.

USE OF THE CONTROLLER

These equipments are designed for the remote control of garage doors, to send the activation commands to control panels and to 
activate/deactivate alarm systems. Its use is not guaranteed for directly activating equipments other than those specified.
The manufacturer reserves the right to modify equipment specifications without prior notice.

1247005v1-2.indd   25

19/05/2010   11:09:50

Содержание ACCESS-1000

Страница 1: ...COD 1247005 1 2 ACCESS 1000 ACCESS 2000 1247005v1 2 indd 1 19 05 2010 11 09 43...

Страница 2: ...tched on Upon receiving a code the equipment checks whether it is in its memory enabling the programmed relay s The position in the memory held by the code received and by the relay s enabling the cha...

Страница 3: ...bles relay 4 Example If channel 1 of the transmitter is to be configured to enable relays 1 and 3 numbers 1 and 3 selected using the numeric keys must be displayed on the screen Every time a numeric k...

Страница 4: ...r to be programmed and press ENTER When ENTER is pressed the controller checks whether the memory space indicated is available and makes the appropriate registrations showing the sequential codes bein...

Страница 5: ...on to be deleted is not programmed the controller will show ERROR 2 on the screen and will return to the menu If no action is made the equipment will automatically exit programming after 60 seconds an...

Страница 6: ...Enter the required channel and press ENTER Enter the number to be discounted maximum 4 digits and press ENTER The controller will issue a sound signal to indicate that the operation is being carried...

Страница 7: ...e the equipment will automatically exit programming after 60 seconds and two short sound signals are given ALARM FUNCTION This function is only configurable using the Assistant programming tool and is...

Страница 8: ...lected time Operations with transmitters Magnetic sensors must be used for card operations with transmitters to be able to distinguish the entry and exit of vehicles to and from an installation Theref...

Страница 9: ...d for the power supply connections Use time delayed fuses EC DECLARATION OF CONFORMITY The manufacturer JCM TECHNOLOGIES S A C Bisbe Morgades 46 Baixos 08500 VIC Barcelona SPAIN declares herewith that...

Страница 10: ...ACCESS 1000 ACCESS 2000 1247005v1 2 indd 60 19 05 2010 11 09 54...

Отзывы: