background image

22

23

If the code being programmed already exists in the memory, the controller will display ERROR 3 and the programmed memory 
position on the screen, issuing a sound signal.  
If the memory position selected is occupied, ERROR 4 will appear on the screen and the controller will jump to the next free 
position, issuing a sound signal.

If  no  action  is  made, the equipment  will  automatically  exit  programming  after  60  seconds  and  two  short  sound  signals  are 
given.  

2.2 DEL CODES

This allows for individual or sequential cancellations or a total reset to be made. 

2.2.1 Per position (POSITION)

Select the memory position to be deleted using the numeric keys and press ENTER. The controller will issue a series of short 
sound signals to indicate that the operation is being carried out.  OK will appear on the screen.

2.2.2 Per code (CODE)

Select the code to be deleted using the numeric keys and press ENTER. The controller will issue a series of short sound signals 
to indicate that the operation is being carried out.  OK will appear on the screen.

2.2.3 Sequential cancellations (RANGE)

Select the memory position to be deleted using the numeric keys and press ENTER. Select the number of codes to be deleted. 
Press ENTER, the controller will issue a series of short sound signals to indicate that the operation is being carried out and the 
message OPERATING will appear on the screen.  Once the operation is complete, OK will appear on the screen.

2.2.4 Total reset (DELETE ALL)

The message HOLD ENTER will appear on the screen and the equipment will issue a series of short warning sounds.  Keep 
ENTER pressed down and the equipment will issue a series of intermittent sounds. OK will appear on the screen. If ESC is pressed 
during warning status, reset is cancelled. 

If the code or position to be deleted is not programmed, the controller will show ERROR 2 on the screen and will return to the 
menu.

If no action is made, the equipment will automatically exit programming after 60 seconds and two short sound signals are given.  

2.3 KILLPASS

This allows for individual or sequential codes to be disabled (the memory position remains occupied). 

On receiving the disabled code, no output is activated on the controller and the message “NO” is shown on the screen. If it is a 
proximity element, it is destroyed and becomes unusable.  

2.3.1 Per position (POSITION)

Select the memory position to be disabled using the numeric keys and press ENTER. The controller will issue a sound signal to 
indicate that the operation is being carried out.  OK will appear on the screen.

2.3.2 Per code (POR CODIGO)

Select the code to be disabled using the numeric keys and press ENTER. The controller will issue a sound signal to indicate that 
the operation is being carried out.  OK will appear on the screen.

2.3.3 RANGE

Select the memory position to be disabled using the numeric keys and press ENTER. Select the number of codes to be disabled. 
Press ENTER, the controller will issue a sound signal to indicate that the operation is being carried out and the message OPERAT-
ING will appear on the screen.  Once the operation is complete, OK will appear on the screen.

To enable a code on a disabled transmitter, enter the registration menu and run an individual registration without indicating the 
position or the code.  The controller will show

 

ERROR 3

 

on the screen and will jump to the programmed memory position, issuing 

a sound signal.  Press the transmitter again and it will become enabled.

  

If the code or position to be deleted is not programmed, the controller will show ERROR 2 on the screen and will return to 
the menu.

If no action is made, the equipment will automatically exit programming after 60 seconds and two short sound signals are given.  

1247005v1-2.indd   22

19/05/2010   11:09:50

Содержание ACCESS-1000

Страница 1: ...COD 1247005 1 2 ACCESS 1000 ACCESS 2000 1247005v1 2 indd 1 19 05 2010 11 09 43...

Страница 2: ...tched on Upon receiving a code the equipment checks whether it is in its memory enabling the programmed relay s The position in the memory held by the code received and by the relay s enabling the cha...

Страница 3: ...bles relay 4 Example If channel 1 of the transmitter is to be configured to enable relays 1 and 3 numbers 1 and 3 selected using the numeric keys must be displayed on the screen Every time a numeric k...

Страница 4: ...r to be programmed and press ENTER When ENTER is pressed the controller checks whether the memory space indicated is available and makes the appropriate registrations showing the sequential codes bein...

Страница 5: ...on to be deleted is not programmed the controller will show ERROR 2 on the screen and will return to the menu If no action is made the equipment will automatically exit programming after 60 seconds an...

Страница 6: ...Enter the required channel and press ENTER Enter the number to be discounted maximum 4 digits and press ENTER The controller will issue a sound signal to indicate that the operation is being carried...

Страница 7: ...e the equipment will automatically exit programming after 60 seconds and two short sound signals are given ALARM FUNCTION This function is only configurable using the Assistant programming tool and is...

Страница 8: ...lected time Operations with transmitters Magnetic sensors must be used for card operations with transmitters to be able to distinguish the entry and exit of vehicles to and from an installation Theref...

Страница 9: ...d for the power supply connections Use time delayed fuses EC DECLARATION OF CONFORMITY The manufacturer JCM TECHNOLOGIES S A C Bisbe Morgades 46 Baixos 08500 VIC Barcelona SPAIN declares herewith that...