RCONTACT R 

User’s Manual 

 

Introduction 

 

The system is designed for applications where pedestrian doors installed on garage doors. Is a position detection system of 

the pedestrian door status, so that if it is open the system prevents the start of the movement of the garage door.  
Is a wireless system composed by one transmitter and one receiver. The receiver monitors the status of transmitters connected to it. 

The system complies with EN ISO 13849-1, category 2, PLc. 

 

Technical data

 

 

Frequency 

869,50 MHz 

Power supply 

12/24V ac/dc (9-35V dc / 8-28V ac) 

Consumption standby/operating 

18mA/80mA 

Memory 

6 transmitters (3 on relay 1, 3 on relay 2) 

Relay numbers 

2 relays 

Relay contacts 

1A 

Radiated power 

< 1mW 

Operating temperature 

-20ºC - +85ºC  

Seal 

IP54 (with IP65 cable glands) 

Box size 

82 x 190 x 40mm 

Range 

50m 

 

 
 
 

 
 
 

 
 
 

 
 

 
 
 

 
 
 

 
 

Starting up

 

 

Mechanical installation 

Fix the back of the box to the wall, using the wall plugs and screws supplied. Install the receiver, close to the door and avoid metal 
surfaces between the receiver and the transmitter. Pass the cables through the bottom of the receiver. Connect the power cables to 

the terminals of the printed circuit, following the indications of the connections diagram. Store the transmitter on the receiver. Fix 
the front of the receiver to the back with the screws supplied for the purpose. 

 

Programming the transmitter on the receiver 

While programming the receiver, press the PROG button on the transmitter to be programmed into the receiver. 
The receiver allows programming 6 transmitters (3 for Relay 1 and 3 for Relay 2). 
Each safety edge transmitter must be learnt into the appropriate channel of the safety edge receiver.  

 