1248099_Rev1.0
RSEC3
Page
4/4
Reset
PRESS RPROG PUSHBUTTON LED TURNS ON
BRIDGE MR SEVERAL BEEPS & END RESET
AND HOLD PRESSED
PRESS RPROG PUSHBUTTON LED TURNS OFF & END PROG
Replacing a transmitter
If a transmitter becomes damaged the whole system must be reset and replaced, and non-damaged transmitters must then be re-
programmed into the receiver.
Use of the system
The system is designed to be installed as specified in the introduction. Other applications than specified are not guaranteed.
Manufacturer reserves the right to change the equipment specification without prior warning
Important annex
Disconnect power supply whenever you proceed any installation or repair of the control panel.
In accordance with the European low voltage directive, the following requirements are informed:
· For permanently connected equipments, an easy-access connection device must be provided.
· This system must only be installed by qualified persons with experience in automatic doors/gates installations and with knowledge of
the applicable EU standards.
· The instructions for use of this equipment must always remain in the possession of the user.
· System’s work frequency does not interfere with the 868 MHz remote control systems.
JCM TECHNOLOGIES, S.A.
declares herewith that the product
RSEC3
complies with the relevant fundamental requirements as per
Article 3 of the R&TTE Directive 1999/5/EG, and complies with the relevant fundamental requirements of the 2006/42/CE Machinery
Directive, as well as with the ones of the 2004/108/CE Electromagnetic Compatibility Directive and 2006/95/CE Low Voltage Directive,
insofar as the product is used correctly.
EC Declaration of conformity
See website www.jcm-tech.com