JCM Technologies ACCESS-5K Скачать руководство пользователя страница 5

Installation

ACCESS-5K

5 - 

jcm

technologies

Wiring

Power supply and relays 

R1

R2

POWER SUPPLY

Connect the power 

supply cables

12/24 

Vac/dc

RELAYS

Connect the R1/R2 relay outputs (Normally 

Open Contact) to the existing elements of 

the installation

ELECTROLOCK

Check power supply 

value for electrolock

CONTROL

PANEL

POWER

Check the power supply led 

is lighted when power 

is turned on

ANT

 COMMS. CARD

ANT

 COMMS. CARD

R1

R2

LED D0

12Vdc

L

D1

RD1

RD2

ANT

 COMMS. CARD

ANT

 COMMS. CARD

R1

R2

LED D0

12Vdc

L

D1

RD1

RD2

12/24V

ac/dc

 Example of installation in control panel.

Содержание ACCESS-5K

Страница 1: ...EN ACCESS 5K ACCESS CONTROL UNIT instruction manual jcmtechnologies ...

Страница 2: ...tion 8 LED Indicators 8 Maintenance 9 Firmware update 9 Cell battery replacement for time date loss 9 Technical Data 10 Electrical parameters 10 Physical parameters 10 Radiofrequency parameters 10 Solving problems 11 FAQs 11 Safety instructions 13 Use of the system 13 EC Declaration of conformity 13 ACCESS 5K Contents 2 jcmtechnologies ...

Страница 3: ...ft Assistant it is secured against transmitter copies It completes the ACCESS family with advanced features 5000 users and events Scheduling for groups and relays 12 24 Vac dc power supply 2 independent Bus L Wiegand26 inputs Improved events management Firmware update General description ANT COMMS CARD ANT COMMS CARD R1 R2 LED D0 12Vdc L D1 RD1 RD2 POWER SUPPLY OUPUT RELAYS R1 R2 PROXIMITY READERS...

Страница 4: ...mtechnologies Installation with support Installation without support Fixing DRILL HANG DEVICE 4 UNSCREW 1 SCREW 5 REMOVE SUPPORT 2 UNSCREW 3 ANT COMMS CARD ANT COMMS CARD R1 R2 LED D0 12Vdc L D1 RD1 RD2 DRILL 3 OPEN TOP COVER 2 1 ...

Страница 5: ...ormally Open Contact to the existing elements of the installation ELECTROLOCK Check power supply value for electrolock CONTROL PANEL POWER Check the power supply led is lighted when power is turned on ANT COMMS CARD ANT COMMS CARD R1 R2 LED D0 12Vdc L D1 RD1 RD2 ANT COMMS CARD ANT COMMS CARD R1 R2 LED D0 12Vdc L D1 RD1 RD2 12 24V ac dc Example of installation in control panel ...

Страница 6: ...s to the RD1 RD2 connectors RD1 RD2 WIEGAND26 Channel 1 for RD1 reader Channel 2 for RD2 reader BUS L Channel is defined in EVOPROX configuration See the EVOPROX user manual for protocol and channel configuration ANT COMMS CARD ANT COMMS CARD R1 R2 LED D0 12Vdc L D1 RD1 RD2 12 24V ac dc Example of installation in EVOPROX readers ...

Страница 7: ...vice can be only configured by the software SoftAssitant Check its user manual and the ACCESS 5K specific annex for details of creating an installation adding devices creating user groups etc For more information visit www jcm tech com en MAESTRO PROGMAN ASSISTANT Keep the plastic cover of micro SD memory in a safe place as it contains the label with the data for remote management ...

Страница 8: ...Flashes Anti panic activation Continous flashing Tamper input activation ERROR 1 Flash Forbiden access 2 Flashes Out of schedule access 3 Flashes Anti passback violation only A5K 4 Flashes Firmware update needed hardware reset 5 Flashes Transmitters code file not found Continous flashing No memory or bad memory format OK 1 Flash Access garanted Continous flashing Reading memoy MEMORY ERROR Contino...

Страница 9: ...he SD to bin a5k Extract the SD memory from the computer Power off your ACCESS 5K Insert the SD memory in your ACCESS 5K Power on your ACCESS 5K If the OK led flashes fast slowly and then fast once again Then The update has finished properly The bin a5k file has been deleted from SD memory If the ERROR led keeps flashing slowly an error has occurred Check the file in the SD memory Delete the firmw...

Страница 10: ... dc ac Standby operating consumption 50 mA 100 mA Maximum power consumption 5W Relay power R1 R2 3A Physical parameters Operating temperature 20ºC 55ºC Size 180 x 150 x 85 mm IP Rating IP65 Radiofrequency parameters Motion Frequency 868 MHz Motion Codification High security rolling code ...

Страница 11: ...ustomer code and the password Q How can the events be read A Connecting the SD card at the computer and opening the events file through SoftAssistant Q Can we power the unit at 230 V A No we can only supply low voltage 12 24 Vac dc Q How many relay outputs does the unit have A It has 2 relay outputs Q Are the relays potential free A Yes also the relays can be used to switch power to an electric lo...

Страница 12: ...ndards The instructions for use of this equipment must always remain in the possession of the user This equipment is designed for applications where pedestrian doors installed on garage doors It is not guaranteed for directly activating equipment other than that specified The manufacturer reserves the right to change the specification of the equipment without prior warning JCM TECHNOLOGIES S A dec...

Отзывы: