Option switch
Option No.
Upper position – ON
Lower position - OFF
1 (AUTO PROG)
Self-programming
Manual programming (default
option)
2 (AUTO CLOSE.)
Automatic closure
Does not close automatically
(default option)
3 (NON STOP ON OPENING)
Does not allow for radio reverse on
opening
Allows for radio reverse on opening
(default option)
4 (SLOW)
Allows for slow speed (default
option)
Does not allow for slow speed
5 (COURTESY L / ELECT)
Garage light comes on (default
option). Garage light contact time =
Operating time + 30 seconds.
Works like an electro-lock (1.5
seconds before opening)
6 (INH.SEC.EDGE 4cm)
Inhibits the security edge for the last
4 cm of the run
Does not inhibit the security edge
(default option)
7 (DEAD MAN)
Dead-man operations
Semi-automatic or automatic oper-
ations (default option)
Input switch
Option No.
Upper position – ON (default
option)
Lower position - OFF
1 (STOP)
Stop button not connected
Stop button connected
2 (SEC.CL.)
Security Close contact not con-
nected
Security Close contact connected
3 (S.EDGE)
Security edge not connected
Security edge connected
4 (FC.CL.)
End of run close not connected
End of run close connected
5 (FC.OP.)
End of run open not connected
End of run open connected
Light indicators
Function
Indicates
Default status
POWER
Power
Normally on
SAFETY
Operating alert (see table)
Normally off
ERROR
Operating fault (see table)
Normally off
TIMER PROG.
Operation programming mode
Normally off
RADIO PROG.
Radio programming mode
Normally flashing
jcm
technologies
6
Содержание CONT-R15
Страница 1: ...CONT R15 User Manual...