jcm-tech CONT-R15 Скачать руководство пользователя страница 1

CONT-R15

User Manual

Содержание CONT-R15

Страница 1: ...CONT R15 User Manual...

Страница 2: ...witch jumpers 7 Buttons 7 Times 7 Programming 8 Self prgramming 8 Manual programming 8 Partial opening programming 8 Sensivity programming 8 Parameter configuration from programmer 9 Receiver operatio...

Страница 3: ...ry 230V ac Transformer 230Vac power supply L 9 24V dc motor 17 Open OPEN NO 2 Primary 230V ac Transformer 230Vac power supply N 10 Encoder 18 Close CLOSE NO 3 Secondary 0V ac Transformer 11 Encoder S...

Страница 4: ...ghtness IP54 Equipment category Class II Base plate size 160x83x27 mm Box size 225x195x85 mm Installation Disconnect the power supply whenever you proceed to the installation main tenance or repair of...

Страница 5: ...ON 24 Vac output To power any equipment at a voltage of 24 Vac with a maximum con sumption of 400 mA Encoder input S H Allows for an NPN type encoder or sensor hall to be connected at 5 Vdc necessary...

Страница 6: ...n Does not inhibit the security edge default option 7 DEAD MAN Dead man operations Semi automatic or automatic oper ations default option Input switch Option No Upper position ON default option Lower...

Страница 7: ...amming is carried out by pulses or by time With the jumper at ON the panel will be programmed by pulses and with the jumper removed it will be programmed by time Current limit level switch jumpers JP4...

Страница 8: ...chanical stops are not used on either of the two ends of the door the START button must be pressed to indicate the limit of the run at the end of the door without the limit switch or mechanical stop M...

Страница 9: ...ogrammer instruction manual for further information Operation by Time Indicates if the panel is programmed to operate by time Operation by Pulses Indicates if the panel is programmed to operate by pul...

Страница 10: ...ill now have entered programming for ped estrian function Press the required channel of the transmitter to be programmed The first channel opens and the second closes 3rd channel opens and 4th channel...

Страница 11: ...Hz 868 MHz This acts on the panel with transmitters proximity keys or smart cards in the same way as the start button Traffic light card Flash card TL CARD Traffic light card This carries out two diff...

Страница 12: ...ce not reached 4 4 flashes off No encoder pulses 5 5 flashes off Panel programmed without references 6 6 flashes off Internal error Use of the equipment This equipment is designed to automate garage d...