VEGA™ Series Banknote Validator
Troubleshooting
Yellow
3
(120)
Purple
3
(120)
Validation Problem
Software version is old, or a disabled denomination Banknote was
inserted.
[Solution] Confirm that the denomination set is the same as the Software
Information Sheet specified, and re-download the correct Software if
different.
Validation Problem
(Most Banknotes are
rejected)
Wrong DIP Switch settings.[Solution] Confirm that the denomination set
is the same as the Software Information Sheet specifies, and re-
download the correct Software if different (See “Software Download
Procedure” on page 6-2).
Inhibit validation due to conflicting Host Command settings.
[Solution] Confirm the Host Command setting and reset the command to
prohibit.
Adhering foreign object or dirt on the Sensors.[Solution] Clean the
Sensors (See “Sensor and Roller Cleaning Procedure” on page 2-5)
Validation Problem
(Only specific
Banknotes are
rejected or the
validation rate is
degraded)
Software version is old, or a disabled denomination Banknote was
inserted.
[Solution] Confirm that the denomination set is the same as the Software
Information Sheet specifies, and re-download the correct Software if
different.
Adhering foreign object or dirt on the Sensors.
[Solution] Clean the Sensors (See “Sensor and Roller Cleaning
Procedure” on page 2-5).
Needs Sensor calibration (after disassembly/reassembly or parts repair/
replacement, perform the necessary Calibration Procedure(s). (See
Yellow
3
(120)
Green
3
(120)
Banknote Length
Problem
Short Banknote length problem: While waiting for Validation Sensor
detection, the Intake Sensor detected “no-bill” present. Or, while
transporting Banknotes, the Escrow Sensor waited for Banknote
insertion detection and the Intake Sensor detected a “no-bill” present
condition.
Long Banknote length problem: Inserted a Banknote having a length
greater than 165mm.
[Solution] Check that the following parts are properly assembled and/or
Harness connected, and clean all of the Sensors
[Relative Parts] Intake Sensor
If the error is not resolved, change the above related part.
Blue
3
(120)
Double Banknotes
The Validation Sensor’s transitional level is less than the accepted value.
Dirt, Sticker, or Foreign Object may be on the Banknote.
[Solution] Confirm the Banknote’s condition
If the error is not resolved, perform a Sensor Calibration.
Yellow
3
(120)
Red
Cash Box Seating
Problem
Cash Box Sensors detect a banknote remaining in path.
[Solution] Check that the following parts are properly assembled and/or
Harness connected, and clean all of the Sensors.
[Relative Parts] Cash Box Sensor
If the error is not resolved, change the above related part.