 VEGA-RC Twin™ Series Banknote Recycler  Integration Guide

Electrical Specifications

Structural Specifications

System Configuration

Figure 5 illustrates a typical VEGA-RC Twin™ System configuration.

Table 4 

VEGA-RC Twin Electrical Specifications

Supply Voltage

*

:

*. Hot-swapping prohibited (e.g., do not plug connectors in or out while the VEGA Unit’s power is ON). The limited power source [Class 2] is required.

VEGA-RC Twin

12V DC ±5%

24-36V DC (Minimum: 20V DC/Maximum: 42.5V DC)(option)

†. If there is voltage ripple on the applied voltage, be sure that the minimum voltage has not fallen below 20V DC and make that ripple as smooth as 

possible.

Current Consumption

:

‡. Power voltage is input voltage for the VEGA Unit. 

VEGA-RC Twin 12 with VEGA Unit

Standby = 0.21A (12V DC)

Operation = 2.2A (12V DC)

Peak = 2.9A (12V DC)

VEGA-RC Twin 42 with VEGA Unit (option)

Standby = 1.6A-0.11A (24-36V DC)

Operation = 1.2A-0.8A (24-36V DC)

Peak = 1.7A (24-36V DC)

Table 5 

VEGA-RC Twin Structural Specifications

Weight:

Approximately 1.8kg (4lbs.)

Mounting:

Horizontal

*

*. Both vertical and transverse types should be installed at a 90-degree angle to the frame.

Outside Dimensions:

See “Entire Unit Outside Dimensions” on page 17 of this Manual

Figure 5 

VEGA-RC Twin System Configuration

a) VEGA-RC Twin connected to the VEGA Unit

b) PC (Windows XP/2000/Vista/7)

c) Power Supply (e.g., VM-VEGA, UAC, etc.)

d) Host Machine

e) Maintenance Connector (VEGA)

f) Standard Marketplace USB Cable

[to VEGA: Mini “B” Plug/to VEGA-RC Twin: Standard “A” Plug]

g) Interface Connector (VEGA)

h) Power Harness

i) Harness

c

a

b

d

e

f

g

h

i

Содержание VEGA-RC Twin Series

Страница 1: ...mited Support http www jcmglobal com en contact default aspx Web Site http www jcmglobal com Issue 4094 IGE 01 00 VEGA RC Twin Series Banknote Recycler Integration Guide Revision A November 21 2012 P N 960 000169R_Rev A EDP 217859 ...

Страница 2: ...aintain operation of the product or operate the product in general JCM retains all rights to amend alter change or delete any portion of this Manual in whole or in part or add items thereto without notice regarding the product or its related products JCM is a registered trademark of Japan CashMachine Co Limited All other product names mentioned herein may be registered trademarks or trademarks of ...

Страница 3: ...ations 7 4 CONNECTOR PIN ASSIGNMENTS 8 Connector Pin Assignments Continued 1 9 5 PREVENTIVE MAINTENANCE 9 Clearing a Banknote Jam 9 Cleaning Procedure 10 Sensor and Roller Cleaning Procedure 10 6 SENSOR AND ROLLER LOCATIONS 11 7 STANDARD INTERFACE CIRCUIT SCHEMATICS 12 Standard Interface Circuit Schematics 12 8 OPERATIONAL FLOWCHART 13 Operational Flowchart Continued 1 14 Operational Flowchart Con...

Страница 4: ...ne Co Limited ii Page VEGA RC Twin Series Banknote Recycler Integration Guide JCM American 21 Europe Africa Russia Middle East 21 JCM Europe GmbH 21 UK Ireland 21 JCM Europe UK Office 21 Asia and Oceania 21 JCM Gold HK Ltd 21 Japan Cash Machine Co Limited HQ 21 13 INDEX 23 ...

Страница 5: ...EGA RC Twin Sensor Cleaning Locations 11 Figure 13 VEGA RC Twin TTL Interface Schematic Diagram Recycler to Acceptor 12 Figure 14 VEGA RC Twin TTL Interface Schematic Diagram Recycler to Indication Board 12 Figure 15 VEGA RC Twin Operational Flowchart Initializing 13 Figure 16 VEGA RC Twin Operational Flowchart Main 14 Figure 17 VEGA RC Twin Operational Flowchart Dispensing 2 15 Figure 18 VEGA RC ...

Страница 6: ...P N 960 000169R_Rev A EDP 217859 2012 Japan CashMachine Co Limited iv THIS PAGE INTENTIONALLY LEFT BLANK VEGA RC Twin Series Banknote Recycler Integration Guide ...

Страница 7: ...ble 4 VEGA RC Twin Electrical Specifications 6 Table 5 VEGA RC Twin Structural Specifications 6 Table 6 LED Pattern Color Indications 7 Table 7 VEGA RC Twin Recycler to Acceptor Receptacle Pin Assignments 8 Table 8 VEGA RC Twin Recycler to Indication Board Receptacle Pin Assignments 9 Table 9 VEGA RC Twin Sensor Type Cleaning Methods 11 Table 10 Operation Error Codes 18 Table 11 Warning Codes 19 T...

Страница 8: ...P N 960 000169R_Rev A EDP 217859 2012 Japan CashMachine Co Limited vi VEGA RC Twin Series Banknote Recycler Integration Guide THIS PAGE INTENTIONALLY LEFT BLANK ...

Страница 9: ...Features Specifications System Configuration Unit Dimensions International Compliance Technical Contact Information In order to make operating this device and navigat ing within this manual easier the following illustra tions are used Safety Instructions need to be observed in order to protect the operators and the equipment these are identified with bold text and the following pictographs Special...

Страница 10: ...ging or unplugging the Recycler s communi cations connector while the VEGA Unit s power is ON may cause damage to the Recycler unit 3 When reassembling a disassembled section ensure that each part is carefully placed in its proper location 4 Be sure to carry the unit using both hands Hold ing the unit with only one hand may cause per sonal injury if the unit comes apart 5 While transporting be car...

Страница 11: ...is capable of recycling any two 2 denominations that the VEGA accepts Each Recycler Drum can store 30 notes that enable it to correspond with worldwide requirements The specific design of the Banknote Winding System improves the overall process The VEGA RC Twin the optional unit of the VEGA features two 2 individual Recycler Drums available for two 2 Banknote denominations WARNING Do not inject wa...

Страница 12: ...mponent Names Figure 4 illustrates the VEGA RC Twin component names and locations Figure 4 VEGA RC Twin Component Names a Two Color LED Indicator b VEGA Attach Release Button c Upper Recycler Drum Thumb Winding Gear Control d Lower Recycler Drum Thumb Winding Gear Control e Rear Course Open Close Button f Gear Cover c e a d b f ...

Страница 13: ... new Banknote e g 100 Euro Banknotes Full detection The number of stored notes can be set to maximum or between 1 and 30 notes No Nearly Full End detection Stacking Method Banknote Winding System DO NOT replace Banknotes by hand winding them back into place Allow them to be replaced by the unit s recycling action only Dispense No denomination discrimination No double note detection e g condition i...

Страница 14: ...urrent Consumption Power voltage is input voltage for the VEGA Unit VEGA RC Twin 12 with VEGA Unit Standby 0 21A 12V DC Operation 2 2A 12V DC Peak 2 9A 12V DC VEGA RC Twin 42 with VEGA Unit option Standby 1 6A 0 11A 24 36V DC Operation 1 2A 0 8A 24 36V DC Peak 1 7A 24 36V DC Table 5 VEGA RC Twin Structural Specifications Weight Approximately 1 8kg 4lbs Mounting Horizontal Both vertical and transve...

Страница 15: ...igure 7 a lock into place between the VEGA RC Twin and the VEGA Unit body 3 Install the VEGA RC Twin Harness Cable Connector into its VEGA Unit mating recepta cle to interconnect the units See Figure 7 b Primary LED Indications The LED Color Pattern indications listed in Table 6 occur during various VEGA RC Twin Unit oper ating and error conditions Figure 6 VEGA RC Twin Positioning Table 6 LED Pat...

Страница 16: ...used 5 VEGA ENC IN Serial data signal input line from Acceptor to Recycler 6 VEGA PSI2 IN Serial data signal input line from Acceptor to Recycler 7 VEGA FRP IN Serial data signal input line from Acceptor to Recycler 8 VEGA PSI1 IN Serial data signal input line from Acceptor to Recycler 9 VDD 12V DC 24 36V DC 10 VDD 12V DC 24 36V DC 11 VDD 12V DC 24 36V DC 12 P GND Power GND 13 P GND Power GND 14 P...

Страница 17: ...ws in blue circles B1 B2 shown in Figure 9 Table 8 VEGA RC Twin Recycler to Indication Board Receptacle Pin Assignments Post with Base Side Type S4B PH K S JST Housing PHR 4 Contact SPH 002T P0 5S AWG 24 30 Recommended Wire Slit Wire AWG 26 Pin No Signal Name I O Function 1 VCC 3 3V DC 2 S GND Signal GND 3 SUB RXD IN Serial data signal input line from Indication Board to Recycler 4 SUB TXD OUT Ser...

Страница 18: ...GA RC Twin Unit s Rear Cover 3 Clean the appropriate path lens and roller Be sure to rotate the Drum Thumb Winding Gear Controls See Figure 10 a in the IN direction when cleaning the rubber rollers See Figure 10 b using the soft lint free cloths Figure 10 Roller Cleaning a b Caution DO NOT rotate the Drum Thumb Winding Gear Controls in the out direction when cleaning The Transport Belt could wind ...

Страница 19: ...ensor Type Cleaning Methods Sym Sensor Roller Type Sym Sensor Roller Type Cleaning Method a Upper Bobbin End Sensor Prism g Lower Tape End Sensor Wipe clean using a soft lint free cloth or blow clean using compressed air b Upper Bobbin End Sensor h Upper Tape End Sensor c Lower Bobbin End Sensor i Positioning Sensor 3 d Lower Bobbin End Sensor Prism j Positioning Sensor 2 e Door Sensor k Positioni...

Страница 20: ...nterface Schematic Diagram Recycler to Acceptor STANDARD INTERFACE CIRCUIT SCHEMATICS Figure 14 illustrates the VEGA RC Twin TTL Interface Schematic Diagram Recycler to Indication Board CONTROLLER SIDE VEGA RC Twin SIDE Figure 13 VEGA RC Twin TTL Interface Schematic Diagram Recycler to Acceptor CONTROLLER SIDE VEGA RC Twin SIDE Figure 14 VEGA RC Twin TTL Interface Schematic Diagram Recycler to Ind...

Страница 21: ...PERATIONAL FLOWCHART Figure 15 depicts part one of a typical VEGA RC Twin Initializing Banknote recycling flow process a Initializing b Stand by c Has a command been received from host A To Main flow See Figure 16 F Return from each flow Apply Power to the VEGA RC Twin Unit Figure 15 VEGA RC Twin Operational Flowchart Initializing ...

Страница 22: ...rom Initializing flow See Figure 15 B To Dispensing 2 flow See Figure 17 b Has Dispense 1 command been received C To Dispensing 1 flow See Figure 18 c Has Retrieving command been received D To Retrieving flow See Figure 17 d Has Clearing Error command been received E To Clearing Error flow See Figure 20 e Has Correcting Log command been received F To Initializing flow See Figure 15 f Sending log t...

Страница 23: ... Has dispensing movement completed c Banknote jam occurred B From Main flow See Figure 16 F To Initializing flow See Figure 15 d Indication count down e Motor stop f Send error to host E To Clearing Error flow See Figure 20 Figure 17 VEGA RC Twin Operational Flowchart Dispensing 2 a Start dispensing Banknotes from lower stacker b Has dispensing movement completed c Banknote jam occurred C From Mai...

Страница 24: ...ng Error Banknote recycling flow pro cess a Start retrieving Banknotes b Has retrieving movement completed c Banknote jam occurred D From Main flow See Figure 16 F To Initializing flow See Figure 15 d Indication count down e Motor stop f Send error to host E To Clearing Error flow See Figure 20 Figure 19 VEGA RC Twin Operational Flowchart Retrieving a Has error cleared E From each flow when error ...

Страница 25: ...igure 21 illustrates the VEGA RC Twin Unit s outside dimensions VEGA RC Twin Unit Clearance Dimensions Figure 22 illustrates the VEGA RC Twin Unit s open Recycler clearance dimensions NOTE All dimensions in millimeters Figure 21 VEGA RC Twin Banknote Recycler s Outside Dimensions NOTE All dimensions in millimeters Figure 22 VEGA RC Twin Banknote Recycler s Clearance Dimensions ...

Страница 26: ...fer to the LED error indication pattern shown in Figure 23 to read the Error Codes tables OPERATION ERROR CODES The VEGA RC Twin connected to the VEGA Unit shows an error LED indication or Error Code when featuring the option board anytime an error occurs like a Banknote jam inside the unit Table 10 lists the possible Banknote jam Error Codes 10 TROUBLESHOOTING 300 msec 300 msec or NOTE The indica...

Страница 27: ...Motor is not moving VEGA RC Twin Motor abnormality error Check that the assemblies are properly connected and or harnessed and all of the unit s sensors are clean 05 Receive different denomination information money class during communication Check that the VEGA RC Twin stacking denomination matches the VEGA limit s command denomination confirm that both denomination settings agree 06 VEGA Unit Mot...

Страница 28: ...Limited 2 0 VEGA RC Twin Series Banknote Recycler Integration Guide 11 INTERNATIONAL COMPLIANCE RoHS Directives UL c UL Marks CE Mark CB Scheme NOTE The above listed compliance confirmations are currently being examined for approval or certification or or or or ...

Страница 29: ...837 7834 Unit B Third Avenue Denbigh West Business Park Bletchley Milton Keynes Buckinghamshire MK1 1DH UK E mail support jcmglobal eu ASIA AND OCEANIA JCM Gold HK Ltd Phone 852 2429 7187 Fax 852 2929 7003 Unit 1 7 3 F Favor Industrial Centre 2 6 Kin Hong Street Kwai Chung N T Hong Kong E mail asiapactechsupport jcmglobal com Japan Cash Machine Co Limited HQ Phone 81 6 6703 8400 Fax 81 6 6707 0348...

Страница 30: ...P N 960 000169R_Rev A EDP 217859 2012 Japan CashMachine Co Limited 2 2 VEGA RC Twin Series Banknote Recycler Integration Guide THIS PAGE INTENTIONALLY LEFT BLANK ...

Страница 31: ... functions Page 17 I Installation steps required for Page 7 M Model Descriptions Product Number Specifications of Page 2 N Navigation within manual procedure for Page 1 P Pin Assignments Table Listing of Page 12 Precautionary Symbols types of Page 2 Primary Features VEGA RC Twin VEGA RC Twin Product Series of Page 3 S Safety pictographs indicating 1 to 3 symbols inside boxed area Page 1 Special No...

Страница 32: ...P N 960 000169R_Rev A EDP 217859 2012 Japan CashMachine Co Limited VEGA RC Twin Series Banknote Recycler Integration Guide Issue 4094 IGE 01 00 ...

Отзывы: