JCM Part No. 960-000097R_Rev. 3
© 2010, JCM American, Corporation
6 - 6
Section 6
Universal Bill Acceptor (UBA-1x-SS & UBA-x4-SS/SU) Programming, Calibration & Test
7. After a short period, the Dialog Box Window
will indicate
"Black Adjustment"
(See Figure
6-17). Open the UBA's Upper Guide,
remove the White Reference Paper and
insert the Black Reference Paper (See Figure
6-19
), firmly close the guide (See Figure
6-19
) and Mouse-click the
OK
Screen
Button
again.
8. Repeat the White and Black Reference Paper
steps as instructed on the Screen until the
"UV Adjustment"
Screen shown in Figure 6-
20 is displayed. Open the UBA Upper
Guide, remove the existing test Reference
Paper and insert the UV Reference Paper in
its place; then Mouse-click on the
OK
Screen
Button
again.
9. Insert the UV Reference Paper so it covers
the White Plastic Area at the rear center of
the Lower Transport path (See Figure 6-21
) with the Label facing UP, and firmly
close the Upper Guide as shown in Figure 6-
21
, then Mouse-click on the
OK
Screen
Button
again.
10. When the "
Adjustment Without Reference
Paper
" Screen appears, open the Upper
Guide and remove the UV Reference Paper,
then firmly close the Upper Guide and
Mouse-click on the
OK
Screen But-
ton again (See Figure 6-22).
11. When the White Adjustment Screen reap-
pears, insert the White Reference paper and
again Mouse-click on the
OK
Screen Button.
12. When adjustment of all of the Optical Sen-
sors is complete, the
"MAG HEAD Adjust-
ment"
Screen will appear (See Figure 6-23).
Figure 6-18
White Test Paper Insertion Request
Figure 6-19
Black Test Paper Insertion Request
Figure 6-20
Set UV Reference Test Screen
Figure 6-21
UV Test Paper Insertion Request
CAUTION: Do not insert the UV
Reference paper past the curved area
of the Transport, an error will occur if
the UV Reference paper is inserted in
too far.
Figure 6-22
Remove UV Reference Test Screen