FUEL CONNECTIONS (WHERE FITTED)
The optional 3-Way Fuel Valve allows the generator to be connected to
feed and return to a remote bulk tank.
The selection lever dictates if the engine will feed from either the base tank
or bulk tank. This selection lever should be fully engaged in the chosen
position.
Please consult the manual for details of maximum distances and acceptable
elevation of bulk fuel tanks.
20
Please consult your manual for full information or consult your local dealer
F
Forward line (3 way valve to lift pump inlet)
G
Return line (engine return to 3 way valve)
H
direction lever
J
Forward line (External fuel tank suction to 3
way valve)
K
Return line (3 way valve outlet to external
fuel tank)
A
External tank
B
Base tank
C
Forward line (fuel tank suction to 3 way
valve)
D
Return line (3 way valve outlet to fuel tank
E
3 way fuel valve