This product should not be thrown in the garbage. 
In accordance with the European directive 2012/19/EU, electronic equipment at the end of its life must 
be collected and returned to an authorized recycling facility.

Warranty

JBC’s 2 year warranty covers this equipment against 
all manufacturing defects, including the replacement 
of defective parts and labour.
Warranty does not cover product wear or misuse. 
In order for the warranty to be valid, equipment must 
be returned, postage paid, to the dealer where it was 
purchased. 

Get 1 extra year JBC warranty by registering here: 
https://www.jbctools.com/productregistration/ 
within 30 days of purchase.

40 mm

50 mm

60 mm

80 mm

100 mm

130 mm

130 mm

para manuales - color gris

200 mm

300 mm

0028953-0422

Содержание NAE-9C

Страница 1: ...INSTRUCTION MANUAL NAU Nano Control Unit ...

Страница 2: ...rass Wool 1 unit Ref CL6210 Nano Control Unit 1 unit Cable Collector and Stand 2 units Ref CC2002 Packing List The following items are included This manual corresponds to the following references NAE 9C 100V NAE 1C 120V NAE 2C 230V Power Cable 1 unit Ref 0024092 100V 0023715 120V 0023714 230V 2 ...

Страница 3: ...atures and Connections Tool extension cord 1m Ref A1205 Accessorie Process Screen 2 8 Color TFT Cartridge Extractor Brass wool Metal brush Stand Intelligent Heat Management Cable collector To Nano Tool Equipotential Connector USB B Connector RJ12 Connector for Robot USB A Connector 40 mm 50 mm 60 mm 80 mm 100 mm 130 mm 130 mm para manuales color gris 200 mm 3 ...

Страница 4: ...PORT 2 ROBOT PEDAL 2 NAU Control Unit PORT 2 ROBOT PEDAL 2 NAU Control Unit PORT 2 ROBOT PEDAL 2 NAU Control Unit PORT 2 ROBOT PEDAL 2 NAU Control Unit PORT 2 ROBOT PEDAL 2 NAU Control Unit PORT 2 ROBOT PEDAL 2 Tool Stand Assembly Tool Stand Replacement Insert the new tool stand 3 and tighten the screw 4 Loosen the screw 1 and withdraw the tool stand 2 4 3 2 1 3 2 1 4 ...

Страница 5: ...s connected to the station with the port they are connected to Display the hours worked in each cycle It is possible to choose the language from a list Allows you to carry out an overall station reset restoring all the parameters to their default values Station troubleshooting available on the product page at www jbctools com Troubleshooting 350ºC Port 2 Power 45 Temp Levels 250 350 380 17 14 NT11...

Страница 6: ...heating ramp up rate of the tool to gradually increase the temperature of the component through all the phases of the soldering process Up to 25 fully configurable soldering profiles can be stored System Notifications The following icons will be displayed on the screen s status bar Station update Download the JBC Update File from www jbctools com software html Insert the USB flash drive with the fil...

Страница 7: ...en the tool is in the holder the power is cut off and the tool cools down to room temperature Tool Menu Set temperature limits Set temperature levels Tool Menu Set Hibernation delay from 0 to 60 min or no Hibernation This revolutionary technology is able to recover tip temperature extremely quickly This allows the user to work at a lower temperature As a result tip life increases by 5 40 mm 50 mm ...

Страница 8: ...ion Connections Connect pedal P405 1 to the same port where the Nano Tweezers 1 are connected In the peripherals menu for the Pedal Activation Mode choose between pressed and released Lift the tweezers from the holder press and hold the pedal to activate the tool and desolder the component Once the pedal is released the tool enters en Hibernation Mode and cools down Desoldering 2 1 not included so...

Страница 9: ...tion JBCs desoldering station is needed Apply the solder paste amount needed to solder the new chip component The use of JBC s DPM Manual Solder Paste Dispenser is recommended Pad Cleaning Solder Paste Dispensing not included sold separately 40 mm 50 mm 60 mm 80 mm 100 mm 130 mm 130 mm para manuales color gris 200 mm 9 ...

Страница 10: ...edal Use the tweezers to position the component on the previously tinned pad Note The inactive tool prevents the component from heating up prematurely Soldering Once in position press and hold the pedal to activate the tweezers and perform the soldering previously Press Mode selected 10 ...

Страница 11: ... into the handle until the mark Use the holes to rotate the cartridges for a proper alignment Important It is essential to insert the cartridges as far as the reference ring for a proper connection Changing Cartridges Save time and change cartridges safely without having to switch the station off 1 Removing 2 Inserting 3 Aligning 1 2 Press back the tap 1 to remove the cleaning system 2 Remove the ...

Страница 12: ...tect the tool status Maintain tip surface clean and tinned prior to storage in order to avoid tip oxidation Rusty and dirty surfaces reduce heat transfer to the solder joint Periodically check all cables and tubes Replace any defective or damaged pieces Use original JBC spare parts only Replace a blown fuse as follows 1 Pull off the fuse holder and remove the fuse If necessary use a tool to lever ...

Страница 13: ...of flux with skin or eyes to prevent irritation Be careful with the fumes produced when soldering Keep your workplace clean and tidy Wear appropriate protective glasses and gloves when working to avoid personal harm Utmost care must be taken with liquid tin waste which can cause burns This appliance can be used by children over the age of eight and also persons with reduced physical sensory or men...

Страница 14: ...Notes 14 ...

Страница 15: ...e Temp Adjustment 50ºC 90ºF through station menu setting Tip to Ground Voltage Resistance Meets and exceed ANSI ESD S20 20 2014 IPC J STD 001F Connections USB A USB B pedal connectors RJ12 connector for robot Ambient Operating Temp 10 50 ºC 50 122 ºF Control Unit Dimensions 140 x 170 x 125 mm L x W x H 5 51 x 6 69 x 4 92 in Total Net Weight 2 12 kg 4 67 lb Total Package Dimensions Weight 280 x 280...

Страница 16: ...rranty covers this equipment against all manufacturing defects including the replacement of defective parts and labour Warranty does not cover product wear or misuse In order for the warranty to be valid equipment must be returned postage paid to the dealer where it was purchased Get 1 extra year JBC warranty by registering here https www jbctools com productregistration within 30 days of purchase...