AMPLIFIER
HF
NETWORK
HF AMPLIFIER
LF OUT
LF
k
FULL-RANGE AMPLIFICATION
BIAMPLIFICATION
*500 Hz, POWER RESPONSE
CORRECTED CARD TO BE USED
FIGURE 4. FULL-RANGE AMPLIFICATION AND BIAMPLIFICATION
TABLE IV. SURROUND SYSTEM DATA
SEATS 4401 MONITOR 8140 DISTRIBUTED
SYSTEM
4671
500-
8 UNITS
30 UNITS @
6 UNITS @
1000
@ 50 WATTS
5 WATTS
100 WATTS
EACH
EACH*
EACH**
1000-
12 UNITS @
38 UNITS @
10 UNITS®
2000
50 WATTS
5 WATTS
100 WATTS
EACH
EACH*
EACH**
*FOR A MAXIMUM LEVEL OF 92 dB
'*FOR A MAXIMUM LEVEL OF 107 dB
BOTH 4401 AND 8140 SURROUND SYSTEMS SHOULD
BE HIGH-PASSED AT 40 Hz OR HIGHER.
TABLE V. SUBWOOFER SELECTION DATA
NUMBER OF MODULES EFFICIENCY
ELECTRICAL
POWER INPUT
ACOUSTIC
POWER
SOUND LEVELS
500- 1000-
1000 SEATS 2000 SEATS
1
2%
300 WATTS
6 WATTS
101 dB
100 dB
2
4%
600 WATTS
24 WATTS
107 dB
106 dB
4
8%
1200 WATTS
96 WATTS
113 dB
112 dB
8
16%
2400 WATTS
384 WATTS
119 dB
118 dB